首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
A simple and sensitive method has been developed for determining honokiol and magnolol in fresh Magnolia obovata (M. obovata) by micro high-performance liquid chromatography with electrochemical detection (microHPLC-ECD). Chromatography was performed using a Capcell Pak C-18 UG 120 microbore octadecylsilica (ODS) column, methanol-water-phosphoric acid (65 : 35 : 0.5, v/v/v), as a mobile phase and applied potential at +0.8 V vs. Ag/AgCl. Peak heights were found linearly related to the amounts of honokiol and magnolol injected from 0.67 pg to 2.0 ng (r>0.999). The detection limits (S/N=3) were 0.13 pg, respectively. Honokiol and magnolol of 0.27 ng were detected with relative standard deviation (RSD) of 0.73 and 1.17% (n=5), respectively. Honokiol and magnolol in Magnolia Bark of the Japanese Pharmacopoeia were extracted with 70% methanol, diluted with a mobile phase, and injected into the microHPLC-ECD for determination. Recoveries of honokiol and magnolol in Magnolia Bark exceeded 98.7% with RSD, less than 0.93% (n=5). Determination of the distributions of honokiol and magnolol in bark, phloem, wood, leaf blades, and petioles of fresh M. obovata were made using weight samples of 40-238 mg. This method is useful to determine honokiol and magnolol in M. obovata, which is a candidate for crude magnolia bark for traditional Japanese herbal medicines.  相似文献   

2.
Fast and sensitive packed capillary column switching liquid chromatography methodology has been developed for the determination of the pesticide rotenone in river water. Sample volumes of up to 1 ml are loaded onto a 23 x 0.25 mm, 5 microm Kromasil C18 packed capillary precolumn using a noneluting solvent composition of water-acetonitrile (99:1, v/v) at flow-rates up to 100 microl/min prior to solute backflushing onto a 200 x 0.32 mm, 3.5 microm Kromasil C18 packed capillary analytical column using a mobile phase of water-acetonitrile (30:70, v/v) at a flow-rate of 5 microl/min. The method was evaluated using river water samples spiked with rotenone in the concentration range 0.5-50 ng/ml using UV detection. The within-assay precision was between 5.0 and 7.7% relative standard deviation (RSD, n = 6) and the between assay precision was between 7.5 and 8.9% RSD (n = 6). The method was linear within the investigated mass range displaying a calibration curve correlation factor of 0.997. The mass limit of detection was 10 pg corresponding to a concentration limit of detection of 10 pg/ml, using time-of-flight mass spectrometry.  相似文献   

3.
《Electroanalysis》2017,29(6):1513-1517
The simultaneous determination of three capsaicinoids in raw red pepper and in foods was studied by liquid chromatography coupled to a coulometric detector. The capsaicinoids were separated on an ODS C18 reversed column by isocratic elution with a mobile phase based on acetonitrile −0.15 M acetic acid (51:49%, v/v) at a flow rate of 0.8 mL min−1. The limit of detection (S/N> 3) was 10 pg (injected mass) at an applied potential of 0.650 V vs. Pd. The peak area of the three studied compounds was found to be related to the amount injected from 50 pg to 100 ng range (r=0.999). The relative standard deviation (RSD, n=10) was comprised between 1.5∼4.4 and 1.0∼3.5 % for 100 pg and 5 ng, respectively. The determination of three capsaicinoids in raw red peppers and red pepper containing foods was successfully realized.  相似文献   

4.
A novel method has been developed for the direct determination of traces of chromium, cobalt, and nickel in TiO2 powder; it entails slurry sampling and electrothermal atomic-absorption spectrometry (ETAAS) with a polytetrafluoroethylene (PTFE) slurry (6% m/v) as fluorinating reagent. The factors which could affect the vaporization of the matrix and analytes were studied in detail; the fluorinating vaporization behavior of the analyte both in the slurry and in solution were also investigated. Owing to the in-situ separation of the matrix, the matrix influences were reduced significantly. The proposed method has been applied to the direct determination of traces of chromium, cobalt, and nickel in high-purity TiO2 powder without chemical pretreatment. Under the optimum experimental conditions the detection limits of the analytes (Cr, Co, and Ni) were 1.9 ng g(-1), 2.4 ng g(-1) and 5.4 ng g(-1), respectively, the relative standard deviations (RSD) were 3.4% (n=6, c=7.0 ng mL(-1)), 2.9% (n=6, c=0.70 ng mL(-1)), and 7.6% (n=6, c=4.0 ng mL(-1)), again respectively, and the characteristic masses for Cr, Co, and Ni were 8.4 pg/ 0.0044A, 9.3 pg/0.0044A, and 40.0 pg/0.0044A, respectively.  相似文献   

5.
A sensitive method for determination of disaturated phosphatidylserine species in the presence of their monounsaturated analogs has been developed, using micro liquid chromatography coupled to electrospray ionization tandem mass spectrometry. The hydrophobic nature of the phosphatidylserine species required a combination of low-eluting sample solvents and sub-ambient temperatures in order to focus large sample volumes up to 20 microL. The samples were dissolved in 2-propanol:hexane:water (20:10:4, v/v/v) prior to 1:9 dilution with ammonium formate buffer:2-propanol:tetrahydrofuran (30:55:15, v/v/v) and final 1:4 dilution with ammonium formate buffer (10 mM):2-propanol: tetrahydrofuran (55:37.5:7.5, v/v/v). The analytical column was a 0.5 x 150 mm stainless steel column packed with 5 microm C30 particles, while the mobile phase contained ammonium formate buffer (10 mM): 2-propanol:tetrahydrofuran (30:55:15, v/v/v). A temperature program from 5 degrees C (hold for 3 minutes) to 75 degrees C at 8 K/min provided separation of the disaturated phosphatidylserine species from their monounsaturated analogs, making available a sensitive determination of the isobaric species. The mass limit of detection for dipalmitoyl phosphatidylserine was 100 pg, corresponding to a concentration limit of detection of 5 pg/microL when using an injection volume of 20 microL. This is an improvement by a factor of 20 as compared to previously reported numbers obtained with conventional LC columns. The within-assay precision of dipalmitoyl phosphatidylserine was 11.9% RSD (n = 3), while the retention time precision was 4.1% RSD (n = 6).  相似文献   

6.
A method based on column switching packed capillary liquid chromatography electrospray mass spectrometry has been developed for the determination of the adduct glyoxal-deoxyguanosine, a biomarker candidate for the assessment of glyoxal exposure, in DNA hydrolysate solutions. Microgram amounts of DNA were isolated and enzymatically hydrolyzed to deoxyribonucleosides, prior to ultrafiltration and subsequent dilution to a sample solution consisting of water-acetonitrile-formic acid (98 : 2 : 0.2, v/v). The sample solution was loaded onto a 1 mm I.D. x 5 mm Hypercarb (5 mum) porous graphitic carbon trap column for analyte enrichment using an injection volume of 200 mul, and was subsequently back-flushed onto a 0.30 mm I.D. x 150 mm Lichrospher diol (5 mum) analytical column. The samples were loaded with a flow rate of 40 mul min(-1) and glyoxal-deoxyguanosine was desorbed from the trap column and eluted with an isocratic mobile phase consisting of water-acetonitrile-formic acid (50 : 50 : 0.2, v/v) at a flow rate of 5 mul min(-1). Mass spectrometric determination of glyoxal-deoxyguanosine was obtained by multiple reaction monitoring of the transition [M + H](+)m/z 326 --> m/z 210. The method was evaluated over the concentration range 0.25-50 ng ml(-1) of glyoxal-deoxyguanosine in the hydrolysate of 5 mug DNA. The method was linear with a correlation coefficient of 0.9998 in this range. The within-day (n = 6) and between-day (n = 6) precisions were determined as 1.2-11% and 1.4-11% RSD, respectively, and the recovery was close to 100%. The mass limit of detection was 15 pg, corresponding to a concentration limit of detection of 75 fg mul(-1) DNA hydrolysate solution, corresponding to 48 adducts per 10(6) normal nucleosides. The method was applied for the determination of glyoxal-deoxyguanosine in DNA hydrolysate solutions of calf thymus DNA and cell cultures after reaction or incubation with glyoxal.  相似文献   

7.
An instrumental set up including on-line solid-phase extraction, nano-liquid chromatography, and nanospray mass spectrometry is constructed to improve the sensitivity for quantitation of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS) in surface water. Sample volumes of 1000 microL are loaded onto a microbore 1.0-mm i.d. x 5 mm, 5 microm Kromasil C(18) enrichment column by a carrier solution consisting of 10mM ammonium acetate in acetonitrile-water (10:90, v/v) at a flow rate of 250 microL/min, providing on-line analyte enrichment and sample clean-up. Backflushed elution onto a 0.1-mm i.d. x 150 mm, 3.5 microm Kromasil C(18) analytical column is conducted using an acetonitrile-10mM ammonium acetate solvent gradient from 30% to 70% acetonitrile. Water samples are added with internal standard (perfluoroheptanoic acid) and filtrated prior to injection. The mass limits of detection of PFOA and PFOS are 0.5 and 1 pg, respectively, corresponding to concentration limits of detection of 500 pg/L and 1 ng/L, respectively. The total time spent on sample preparation, chromatography, and detection is approximately 12 min per sample. The method was employed for the determination of PFOS and PFOA in urban river water.  相似文献   

8.
手性高效液相色谱法测定板蓝根中表告依春和告依春含量   总被引:2,自引:0,他引:2  
聂黎行  王钢力  戴忠  林瑞超 《色谱》2010,28(10):1001-1004
采用Chiralpak IC手性柱(250 mm×4.6 mm, 5 μm),建立了正相高效液相色谱测定板蓝根中表告依春(R-告依春)和告依春(S-告依春)含量的方法。考察了流动相组成、流速和柱温对分离度的影响。经优化后的实验条件: 以正己烷-异丙醇(体积比为90:10)为流动相,流速为0.8 mL/min;检测波长为245 nm,柱温为20 ℃。在此优化条件下,表告依春和告依春分离度为3.4,检出限为2.0 mg/L,在0.02~2.0 g/L范围内有良好的线性关系,平均回收率为101%,相对标准偏差(RSD)小于3.0%(n=6)。本方法可将具有抗病毒活性的表告依春与其对映体告依春基线分离并测定,专属性强,能有效控制板蓝根的质量。  相似文献   

9.
The simultaneous determination of four para‐hydroxybenzoic acid esters (parabens) in shampoos was studied by liquid chromatography (LC) with amperometric (LC‐AD) and coulometric (LC‐CD) detection. The parabens were separated on an ODS C18 reversed column by isocratic elution with a mobile phase based on methanol‐0.1 M acetic acid (60 : 40%, v/v) with 0.02 M NaClO4 at a flow rate of 0.8 mL min?1. The limit of detection (S/N>3) for the analytes was in the 15–25 pg (injected mass) range at an applied potential of 1.20 V vs. Ag/AgCl using the LC‐AD and in the 2–3 pg range at a potential of 0.790 V vs. Pd using the LC‐CD. The peak ratio of the internal standard peak (IS: 4‐hydroxybenzoic acid sec‐butyl ester) versus the analyte peak was found to be related to the amount injected from 0.1 ng to 100ng (r=0.996–0.999) with the LC‐AD and from 0.050 ng to 100 ng range (r=0.999–1.000) with the LC‐CD. The relative standard deviation (RSD, n=10) was comprised between 1.8 to 3.5% by LC‐AD ( 5 ng injected) and between 2.0 to 2.4% by LC‐CD (0.5 ng injected). The determination of four most used parabens in ten different shampoos was successfully realized.  相似文献   

10.
高效液相色谱法分析生物样品中的敌鼠   总被引:2,自引:0,他引:2  
杨士云  潘冠民  孟广范  张大明 《色谱》2001,19(3):245-247
 研究用阴离子交换、氰基及硅胶柱固相萃取技术分离提取血、尿、肝及肾中的敌鼠。以香豆素作内标 ,用高效液相色谱 二极管阵列检测器方法进行分离鉴定。色谱条件 :分析柱为HypersilBDSC18(5 μm ,15 0mm× 4 6mmi.d .) ,保护柱为PhenomenexODS(4mm× 3 0mmi.d .) ;流动相 :A为 0 5 %离子对A水溶液 ,B为 0 5 %离子对A甲醇溶液 ,以梯度淋洗程序分离 ;检测波长为 2 86nm。当敌鼠的质量浓度在 1mg/L~ 10 0mg/L范围时 ,其浓度同其峰面积与内标物的峰面积之比有良好的线性关系 (r=0 9999) ,最小检出限量为 5ng(按S/N =3计 )。  相似文献   

11.
建立了一种贝类组织中原多甲藻酸(azaspiracid, AZA)贝类毒素主要成分AZA1的高效液相色谱-串联质谱检测方法。本方法采用甲醇-水(80:20, v/v)溶液对贝类组织中AZA1进行提取,并用MAX阴离子交换固相萃取(SPE)柱富集净化,使用Atlantis dC18(150 mm×4.6 mm, 5.0 μm)色谱柱分离,以含有50 mmol/L甲酸和2 mmol/L甲酸铵的乙腈-水溶液(80:20, v/v)为流动相进行等度洗脱,质谱采用选择反应监测(SRM)模式。AZA1在5 min内获得完全分离,且在48.85~2 442 ng/L范围内线性良好,相关系数为0.998 1。该方法检出限(S/N=3)为11.00 pg/g,添加水平为36.64、73.27、146.54 pg/g时的平均回收率为75.8%~82.5%(n=6),相对标准偏差小于10%。利用该方法对采自大连、青岛、广州水产品市场上的112个贝类样品进行了分析,发现采自大连和广州的部分贝类样品中含有AZA1。结果表明,该方法具有简单、快速、灵敏度高等特点,能充分满足贝类中AZA1检测的要求。  相似文献   

12.
Qin W  Li SF 《Electrophoresis》2002,23(24):4110-4116
Ionic liquid (IL) was covalently bonded onto the silica capillary surface and the electroosmotic flow was reversed over a pH range of 3.5 to 7. Sildenafil (SL) and its metabolite UK-103,320 (UK) in human serum were detected by solid-phase extraction followed by capillary zone electrophoresis-mass spectrometry analysis. The running buffer contained 10 mM acetic acid adjusted to pH 4.5 with 1 M ammonia, and the separating voltage was set to -25 kV. The adsorption of the analytes onto the bare capillary wall was eliminated by the IL coating and the drugs were baseline-separated within 14 min with detection limits (S/N = 3) of 14 and 17 ng/mL for SL and UK, respectively. The method developed showed good intraday precision in terms of relative standard deviation (RSD) with respect to migration time (RSD 相似文献   

13.
A study was carried out on the direct determination of Cr and Mn in urine using simultaneous atomic absorption spectrometry (SIMAAS). The heating program conditions, the absorbance signal profiles, the influence of different chemical modifiers, and the urine sample volume delivery into the tube were optimized to perform the calibration with aqueous solutions. Among several chemical modifiers tested, the best recovery and repeatability results were obtained for 3 microg Mg(NO3)2. On using this modifier, the pyrolysis and atomization temperatures for simultaneous determination of Cr and Mn were 1,300 degrees C and 2,500 degrees C, respectively. Urine samples were diluted (1+1) with 2.0% (v/v) HNO3 + 0.05% (w/v) Triton X-100 prepared in high purity water. A 20-microL aliquot of analytical solution and 10 microL of chemical modifier solution were delivered to the graphite tube. The characteristic masses were 7.8 pg for Cr (RSD=4.0%) and 4.6 pg for Mn (RSD=2.6%). The limits of detection were 0.08 microg L(-1) (n=20, 3s) for Cr and 0.16 microg L(-1) (n=20, 3s) for Mn. Recovery studies for 1.0 or 2.5 microg L(-1) of Cr and Mn added to different urine samples showed acceptable results for Cr (100%, RSD=14%) and Mn (88%, RSD=5.6%).  相似文献   

14.
Atrasentan is an endothelin antagonist selective for the ET(A) receptor in development at Abbott Laboratories for the treatment of cardiovascular disease and cell proliferation disorders. A simple and sensitive chromatographic method for the determination of atrasentan in human plasma has been developed and validated. The analytical method involves acidification of the plasma samples with 0.3 N HCl prior to extraction with 1:1 (v:v) hexane/tert-butylmethylether. The organic extract was evaporated to dryness, reconstituted with 20:80 (v:v) acetonitrile/0.05 M K(2)HPO(4) and washed with 75:25 (v:v) hexane/tert-butylmethylether. The organic layer was discarded and the aqueous layer was injected into the HPLC. Atrasentan and internal standard (ABT-790) were separated from interference using a 250 x 4.6 mm, 5 microm, 120 A Phenomenex Spherisorb C(8) analytical column with a 50 x 4.6 mm, Alltech Absorbosphere 5 microm CN guard cartridge using a mobile phase consisting of 25:15:5:55 (v:v:v:v) acetonitrile/isopropanol/methanol/0.05 M K(2)HPO(4), pH 7.0, at a flow rate of 1.0 mL/min. Fluorescence detection was achieved using lambda(ex) 278 nm and lambda(em) 322 nm. For a 1.0 mL plasma sample volume, the limit of quantitation was approximately 200 pg/mL. The method was linear from 0.2 to 1300 ng/mL (r(2) = 0.9986). Inter- and intra-day assay RSD (n = 6) were less than 10%. Mean accuracy determinations showed the quality control samples to range between 94 and 99% of the theoretical concentration.  相似文献   

15.
A molecularly imprinted polymer prepared using 1-allylpiperazine (1-ALPP) as the functional monomer, trimethyltrimethacrylate (TRIM) as the crosslinker and the zearalenone (ZON)-mimicking template cyclododecanyl-2,4-dihydroxybenzoate (CDHB) has been applied to the clean-up and preconcentration of this mycotoxin (zearalenone) and a related metabolite, alpha-zearalenol (alpha-ZOL), from cereal and swine feed sample extracts. The extraction of ZON and alpha-ZOL from the food samples was accomplished using pressurized liquid extraction (PLE) with MeOH/ACN (50:50, v/v) as the extraction solvent, at 50 degrees C and 1500 psi. The extracted samples were cleaned up and preconcentrated through the MIP cartridge and analyzed using HPLC with fluorescence detection (lambda (exc)=271/ lambda (em)=452 nm). The stationary phase was a polar endcapped C18 column, and ACN/MeOH/water 10/55/35 (v/v/v, 15 mM ammonium acetate) at a flow rate of 1.0 mL min(-1) was used as the mobile phase. The method was applied to the analysis of ZON and alpha-ZOL in wheat, corn, barley, rye, rice and swine feed samples fortified with 50, 100 and 400 ng g(-1) of both mycotoxins, and it gave recoveries of between 85 and 97% (RSD 2.1-6.7%, n=3) and 87-97% (RSD 2.3-5.6%, n=3) for alpha-ZOL and ZON, respectively. The method was validated using a corn reference material for ZON.  相似文献   

16.
高效液相色谱法测定血管紧张素转化酶抑制剂的活性   总被引:22,自引:0,他引:22  
吴琼英  马海乐  骆琳  吴守一 《色谱》2005,23(1):79-81
建立了体外直接测定血管紧张素转化酶抑制剂活性的高效液相色谱分析方法。以马尿酰-组氨酰-亮氨酸为反应底物,血管紧张素转化酶为催化剂,反应所生成的马尿酸为测定指标,未加酶抑制剂的反应为空白对照。使用ZORBAX SB-C18色谱柱(4.6 mm i.d.×150 mm,填料粒径5 μm),柱温25 ℃,流动相为乙腈-超纯水(体积比为25∶75,各含0.05%(体积分数)三氟乙酸及0.1%(体积分数)三乙胺),流速0.5 mL/min,检测波长228 nm。在马尿酸浓度为0.005~1.000 mmol/L时,马尿酸浓度与其峰面积呈良好的线性关系(r=0.9999),最小检测限为0.50 μmol/L;该方法对马尿酸的回收率为99.48%~105.64%,相对标准偏差(RSD)为2.20%(n=6)。该方法可适用于血管紧张素转化酶抑制剂活性的体外测定,具有操作简便、精密度和准确性高的特点,为降血压药物的研制提供了方便可靠的检测手段。  相似文献   

17.
The zearalenone content of maize, wheat, barley, swine feed, and poultry feed samples was determined by immunoaffinity column cleanup followed by liquid chromatography (IAC-LC). Samples were extracted in methanol-water (8 + 2, v/v) solution. The filtered extract was diluted with distilled water and applied to immunoaffinity columns. Zearalenone was eluted with methanol, dried by evaporation, and dissolved in acetonitrile-water (3 + 7, v/v). Zearalenone was separated by isocratic elution of acetonitrile-water (50 + 50, v/v) on reversed-phase C18 column. The quantitative analysis was performed by fluorescence detector and confirmation was based on the UV spectrum obtained by a diode array detector. The mean recovery rate of zearalenone was 82-97% (RSD, 1.4-4.1%) on the original (single-use) immunoaffinity columns. The limit of detection of zearalenone by fluorescence was 10 ng/g at a signal-to-noise ratio of 10:1 and 30 ng/g by spectral confirmation in UV. A good correlation was found (R2 = 0.89) between the results obtained by IAC-LC and by the official AOAC-LC method. The specificity of the method was increased by using fluorescence detection in parallel with UV detection. This method was applicable to the determination of zearalenone content in cereals and other kinds of feedstuffs. Reusability of immunoaffinity columns was examined by washing with water after sample elution and allowing columns to stand for 24 h at room temperature. The zearalenone recovery rate of the regenerated columns varied between 79 and 95% (RSD, 3.2-6.3%). Columns can be regenerated at least 3 times without altering their performance and without affecting the results of repeated determinations.  相似文献   

18.
Polyethylene glycol (PEG) 20000 in low-density polyethylene has been determined using column switching and inverse temperature programming in reversed-phase packed capillary liquid chromatography with evaporative light scattering detection. PEG 20000 was extracted into water from the polyethylene dissolved in toluene and PEG 35000 was added as an internal standard (I.S.). The samples in aliquots of 100 microl were reconcentrated on the enrichment column using a loading mobile phase of acetonitrile-water (3:97, v/v) at a flow-rate of 75 microl/min for 3 min, then back-flushed and separated on the analytical column with acetonitrile-THF-water (40:5:55, v/v) as mobile phase. The column temperature was reduced from 68 to 55 degrees C with a ramp of -1.5 degrees C/min, held constant for 3 min and then reduced further to 45 degrees C with a -1.5 degrees C/min ramp and kept constant for 1 min. The analysis runtime was 20 min. The recovery of PEG 20 000 was determined to 65.1% with 2.8% RSD and the mass limit of detection of PEG 20 000 was 1.25 microg. The within-assay and between day precision of the retention times of both PEG 20000 and PEG 35000 displayed RSD of less than 1.1% (n = 9), while the overall area ratio RSD of 100 microg/ml PEG 20000 over PEG 35000 was 1.3% (n = 9). The method was linear within the investigated concentration range 25-125 microg/ml (R2 = 0.9983). In addition, a mixture of PEG 4000, 8000, 10000, 20000 and 35000 was analysed on the system to demonstrate the possibility of analysing several PEGs in a sample with the use of temperature gradient elution.  相似文献   

19.
A simple and sensitive HPLC method that does not require derivatization for determining cholesterol has been developed. Investigation of voltammetric behavior of cholesterol showed that cholesterol could be oxidized on a glassy carbon electrode in non-aqueous solvents. This was applied to the development of a method by HPLC with electrochemical detection (HPLC-ED). The HPLC-ED was optimized using the separation of cholesterol and oxysterols including 26-hydroxycholesterol and 24S-hydroxycholesterol. The separation was carried out with a Develosil C30-UG-3 column; acetonitrile-2-propanol (9:1, v/v) containing 50mM LiClO(4) as a mobile phase; and an applied potential at 1.9V versus Ag/AgCl. The current peak height was linearly related to the amount of cholesterol injected from 0.5-100 microM (r>0.999). The detection limit (S/N=3) of cholesterol was 0.36 microM (1.8 pmol). Cholesterol at 100 microM was directly detected with a relative standard deviation (RSD) of less than 1.0% (n=8). Total cholesterol and free cholesterol in control human serum were determined by the present method with the recovery of more than 90% and the RSD (n=6) of less than 3.0%.  相似文献   

20.
In the present work, a rapid, accurate, and sensitive method has been developed for the quantitative determination of five fluoroquinolones (enoxacin, ofloxacin, norfloxacin, ciprofloxacin, and enrofloxacin) in edible animal tissues (muscle tissue, liver, kidney, and eggs). The separation was accomplished on an Inertsil (250 x 4 mm) C8, 5 microm, analytical column, at ambient temperature within 15 min. The mobile phase consisted of a mixture of citric acid (0.4 mol L(-1))-CH3OH-CH3CN (87:9:4% v/v). UV detection at 275 nm yielded the following limits of detection: 100 pg per 20 microL injected volume for enoxacin, norfloxacin, and ciprofloxacin, 20 pg for ofloxacin, and 200 pg for enrofloxacin. Peaks in real samples were identified by means of a photodiode array detector. The method was validated in terms of intra-day (n = 8) and inter-day (n = 8) precision and accuracy. Tissue samples were purified from endogenous interference by solid-phase extraction using Oasis HLB cartridges. The solid-phase extraction protocol was optimized in terms of retention and elution. Recovery rates at fortification levels of 40, 60, and 80 ng/g ranged from 82.5% to 111.1%. The applicability of the method was examined using real samples from a chicken treated orally with the five studied fluoroquinolones.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏