首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Li H  He J  Liu Q  Huo Z  Liang S  Liang Y  Ito Y 《Chromatographia》2011,73(1-2):171-175
A simple, selective and sensitive reversed-phase high performance liquid chromatography method for simultaneous analysis of hydrochlorothiazide and reserpine in human urine was developed and subjected to primary pharmacokinetic study. After a simple protein precipitation using methanol and extraction with ethyl acetate, the analytes were separated on an Elite C(18) column at a flow rate of 0.8 mL min(-1). The mobile phase was composed of acetonitrile (A) and 0.2% ammonium chloride solution (B) for a gradient elution starting at A:B at 30:70, v/v for 0~6 min, linearly raising the percent of A from 30% to 50% (6~9 min) and ending at 50:50, v/v (9~25 min). The standard curves were linear over the range of 0.05-20 μg mL(-1) for hydrochlorothiazide and 0.02-5.0 μg mL(-1) for reserpine, respectively (r > 0.999). The limit of detection (LOD) and the limit of quantification (LOQ) were 5.5 ng mL(-1) and 18.2 ng mL(-1) for hydrochlorothiazide, and 7.1 ng mL(-1) and 23.6 ng mL(-1) for reserpine, respectively. The recoveries for both analytes were above 89.0±1.35%. The intra-day and inter-day precision for hydrochlorothiazide were less than 1.91% and 1.38%, and those for reserpine were below 1.61% and 2.64%, respectively. The method indicated good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy, and it was employed successfully for the simultaneous determination of hydrochlorothiazide and reserpine in human urine samples.  相似文献   

2.
P. D. Bari  A. R. Rote 《Chromatographia》2009,69(11-12):1469-1472
Two new, rapid, precise, accurate and specific chromatographic methods were described for the simultaneous determination of olmesartan medoxomil and hydrochlorothiazide in combined tablet dosage forms. The first method was based on reversed phase liquid chromatography using an Eurosphere 100 RP C18 column (250 × 4.6 mm ID, 5 μm). The mobile phase was methanol–0.05% o-phosphoric acid (60:40 v/v) at a flow rate of 1.0 mL min?1. Commercially available tablets and laboratory mixtures containing both drugs were assayed and detected using a UV detector at 270 nm. The second method involved silica gel 60 F254 high performance thin layer chromatography and densitometric detection at 254 nm using acetonitrile–ethyl acetate–glacial acid (7:3:0.4 v/v/v) as the mobile phase. Calibration curves ranged between 200–600 and 125–375 ng spot?1 for olmesartan and hydrochlorothiazide, respectively.  相似文献   

3.
Bari  P. D.  Rote  A. R. 《Chromatographia》2009,69(11):1469-1472

Two new, rapid, precise, accurate and specific chromatographic methods were described for the simultaneous determination of olmesartan medoxomil and hydrochlorothiazide in combined tablet dosage forms. The first method was based on reversed phase liquid chromatography using an Eurosphere 100 RP C18 column (250 × 4.6 mm ID, 5 μm). The mobile phase was methanol–0.05% o-phosphoric acid (60:40 v/v) at a flow rate of 1.0 mL min−1. Commercially available tablets and laboratory mixtures containing both drugs were assayed and detected using a UV detector at 270 nm. The second method involved silica gel 60 F254 high performance thin layer chromatography and densitometric detection at 254 nm using acetonitrile–ethyl acetate–glacial acid (7:3:0.4 v/v/v) as the mobile phase. Calibration curves ranged between 200–600 and 125–375 ng spot−1 for olmesartan and hydrochlorothiazide, respectively.

  相似文献   

4.
A high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of niflumic acid and its prodrug, talniflumate, in human plasma. Niflumic acid and talniflumate were eluted isocratically with methanol-water (73:27, v/v, adjusted to pH 3.5 by acetic acid) at a fl ow rate of 1 mL/min. Indomethacin was used as an internal standard. Signals were monitored by an UV detector at 288 nm. Retention times of indomethacin, niflumic acid and talniflumate were 5.9, 7.2 and 13.5 min, respectively. Calibration plots were linear over the range 50-5000 ng/mL for niflumic acid and 100-5000 ng/mL for talniflumate. The limits of quantitation were 50 ng/mL for niflumic acid and 100 ng/mL for talniflumate. The intra- and inter-day relative standard deviations (RSD) of niflumic acid and talniflumate were less than 10% and the accuracies were higher than 90%. This method is rapid, sensitive and reproducible for the determination of niflumic acid and talniflumate in human plasma.  相似文献   

5.
Simple, rapid, and selective RP-HPLC methods with UV detection were developed for simultaneous determination of chlordiazepoxide hydrochloride and mebeverine hydrochloride (Mixture I) and carvedilol and hydrochlorothiazide (Mixture II). The chromatographic separation in both mixtures was achieved by using an RP-C8 (octylsilyl) analytical column. For Mixture I, a mobile phase composed of acetonitrile-0.05 M disodium hydrogen phosphate-triethylamine (50 + 50 + 0.2, v/v/v), pH 2.5, was used; the detector wavelength was 247 nm. For Mixture II, the mobile phase consisted of acetonitrile-0.05 M disodium hydrogen phosphate (50 + 50, v/v), pH 4.0, and the detector was set at 220 nm. Quantification of the analytes was based on measuring their peak areas. Both mixtures were resolved in less than 6 min. The reliability and analytical performance of the proposed HPLC procedures were statistically validated with respect to linearity, range, precision, accuracy, selectivity, robustness, LOD, and LOQ. The linear dynamic ranges were 2.5-150 and 2.5-500 microg/mL for chlordiazepoxide HCI and mebeverine HCI, respectively, and 0.25-200 and 0.25-150 microg/mL for carvedilol and hydrochlorothiazide, respectively. The validated HPLC methods were successfully applied to the analysis of their commercial tablet dosage forms, for which no interfering peaks were encountered from common pharmaceutical adjuvants.  相似文献   

6.
This study aimed at optimizing and validating a sensitive method for simultaneous determination of bisphenol A (BPA), triclosan (TCS), and tetrabromobisphenol A (TBBPA) in human serum using solid-phase extraction (SPE) and gas chromatography coupled to electron-capture negative-ionization mass spectrometry (GC-ECNI/MS). Sample preparation involved denaturation of serum proteins with formic acid followed by SPE on an Oasis HLB cartridge. Fractionation was performed on Florisil from which the phenolic compounds were eluted with methanol-dichloromethane (DCM) (5:1, v/v). The phenolic fraction was further derivatized with pentafluoropropionic acid anhydride (30 min at 70 degrees C). Further liquid-liquid partitioning using hexane-DCM (4:1, v/v) and K(2)CO(3) 3% aqueous solution was used to eliminate excess reagent and acidic by-products formed during derivatization. The cleaned extract was injected into a GC-ECNI/MS system operated in selected ion monitoring mode. For thorough method validation, each step of the procedure was rigorously optimized. The method limits of quantitation for BPA, TCS, and TBBPA were 0.28 ng mL(-1), 0.09 ng mL(-1) and 0.05 ng mL(-1), respectively. Furthermore, the method was applied to 21 Belgian human serum samples. The median concentrations obtained for BPA (0.71 ng mL(-1)) and TCS (0.52 ng mL(-1)) in Belgian human serum samples were similar to previously reported data for human fluids. Slightly higher levels of TBBPA (0.08 ng mL(-1)) were found in Belgium samples compared to Norwegian serum.  相似文献   

7.
A simple, specific, accurate and precise stability-indicating reversed-phase high-performance liquid chromatographic method was developed for simultaneous estimation of olmesartan medoxomile (OLME), amlodipine besylate (AMLO) and hydrochlorothiazide (HCTZ) in tablet dosage form. The method was developed using an RP C18 base deactivated silica column (250 × 4.6 mm, 5 μm) with a mobile phase consisting of triethylamine (pH 3.0) adjusted with orthophosphoric acid (A) and acetonitrile (B), with a timed gradient program of T/%B: 0/30, 7/70, 8/30, 10/30 with a flow rate of 1.4 mL/min. Ultraviolet detection was used at 236 nm. The retention times for OLME, AMLO and HCTZ were found to be 6.72, 4.28 and 2.30, respectively. The proposed method was validated for precision, accuracy, linearity, range, robustness, ruggedness and force degradation study. The calibration curves of OLME, AMLO and HCTZ were linear over the range of 50-150, 12.5-37.5 and 31-93 μg/mL, respectively. The method was found to be sensitive. The limits of detection of OLME, AMLO and HCTZ were determined 0.19, 0.16 and 0.22 μg/mL and limits of quantification of OLME, AMLO and HCTZ were determined 0.57, 0.49 and 0.66, respectively. Forced degradation study was performed according to International Conference on Harmonization guidelines.  相似文献   

8.
A simple and sensitive direct injection chromatographic procedure is developed for the determination of heroin, two of its metabolites (morphine and 6-monoacetylmorphine (6-MAM)), and benzoylecgonine (a metabolite of cocaine) in serum samples. The proper resolution of the four substances is obtained with a chemometrics approach, where the retention is modelled as a first step using the retention factors obtained in a limited number of mobile phases. Afterwards, an optimisation criterion that takes into account the position and shape of the chromatographic peaks is applied. The mobile phase selected to carry out the analysis was 0.1 mol L(-1) SDS-4% (v/v) butanol buffered at pH 7, in which the separation is performed in less than 18 min. The limits of quantification were in the 17-36 ng mL(-1) range. Intra- and inter-day assay accuracy and precision (below 3%) were obtained following ICH guidelines. The method developed was applied to the determination of the drugs studied in serum samples with good recoveries (90-104%). Serum samples from subjects that have been ingested cocaine and heroin were also analysed. The samples were injected directly in the chromatographic system without any pretreatment.  相似文献   

9.
A simultaneous determination of aspirin (ASA) and its metabolite, salicylic acid (SA), in human serum by a semi-micro column HPLC-UV was developed. A relatively small size of serum sample (100 microL) containing ASA and SA was cleaned up by a simple solid phase extraction. A good separation of ASA and SA could be achieved within 25 min using a semi-micro ODS column with an eluent of MeOH/0.7 mm phosphoric acid solution (pH 2.5) = 50:50 (v/v). The calibration curves for ASA and SA showed good linearity (r = 0.999) with the detection limits 114 and 38 ng/mL at a signal-to-noise ratio of 3, respectively. ASA and SA in patients' sera administered with low-dose enteric-coated aspirin were determined, and the concentration ranges obtained for ASA and SA were 1.2-2.2 and 0.5-57.3 microg/mL, respectively.  相似文献   

10.
A simple HPLC method was developed for determination of quercitrin and isoquercitrin in rat plasma. Reversed-phase HPLC was employed for the quantitative analysis using kaempferol-3-O-beta-D-glucopyranoside-7-O-alpha-L-rhamnoside as an internal standard. Following extraction from the plasma samples with ethyl acetate-isopropanol (95:5, v/v), these two compounds were successfully separated on a Luna C(18) column (250 x 4.6 mm, 5 microm) with isocratic elution of acetonitrile-0.5% aqueous acetic acid (17:83, v/v) as the mobile phase. The flow-rate was set at 1 mL/min and the eluent was detected at 350 nm for both quercitrin and isoquercitrin. The method was linear over the studied ranges of 50-6000 and 50-5000 ng/mL for quercitrin and isoquercitrin, respectively. The intra- and inter-day precisions of the analysis were better than 13.1 and 13.2%, respectively. The lower limits of quantitation for quercitrin and isoquercitrin in plasma were both of 50 ng/mL. The mean extraction recoveries were 73 and 61% for quercitrin and isoquercitrin, respectively. The validated method was successfully applied to pharmacokinetic studies of the two analytes in rat plasma after the oral administration of Hypericum japonicum thunb. ethanol extract.  相似文献   

11.
An environmentally friendly ionic liquids dispersive liquid–liquid microextraction (IL‐DLLME) method coupled with high‐performance liquid chromatography (HPLC) for the determination of antihypertensive drugs irbesartan and valsartan in human urine samples was developed. The HPLC separations were accomplished in less than 10 min using a reversed‐phase C18 column (250 × 4.60 mm i.d., 5 µm) with a mobile phase containing 0.3 % formic acid solution and methanol (v/v, 3:7; flow rate, 1.0 mL/min). UV absorption responses at 236 nm were linear over a wide concentration range from 50 µg/mL to the detection limits of 3.3 µg/L for valsartan and 1.5 µg/L for irbesartan. The effective parameters on IL‐DLLME, such as ionic liquid types and their amounts, disperser solvent types and their volume, pH of the sample and extraction time were studied and optimized. The developed IL‐DLLME‐HPLC was successfully applied for evaluation of the urine irbesartan and valsartan profile following oral capsules administration. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

12.
《Analytical letters》2012,45(15):3225-3237
ABSTRACT

Two procedures were developed for simultaneous determination of benazepril hydrochloride (I) and hydrochlorothiazide (II) in pure, laboratory made mixtures and in pharmaceutical dosage form “Cibadrex tablets® using reversed phase high performance liquid chromatographic and thin layer chromatographic methods.

For reversed phase HPLC, a new very sensitive, rapid, selective method was developed. The linearity ranges were 32-448 ng/20 μl and 40-560 ng/20 μl for benazepril hydrochloride and hydrochlorothiazide, respectively. The corresponding recoveries were 99.38 ± 1.526 and 99.2 ± 1.123.

The minimum detection limits were 7 ng/20 μl and 14 ng/20 μl for benazepril hydrochloride and hydrochlorothiazide respectively.

On the other hand, a new, simple, sensitive and fast thin layer chromatographic scanning densitometric method was developed for simultaneous determination of benazepril hydrochloride and hydrochlorothiazide using ethyl acetate: methanol: ammonia (85: 20: 10 v/v) as the developing system. The Rf values were 0.33 & 0.68 for benazepril hydrochloride and hydrochlorothiazide respectively. The minimum detection limit obtained was 0.12 μg/spot for benazepril hydrochloride and 0.24 μg/spot for hydrochlorothiazide. The mean percentage recoveries were 100.04 ± 1.102 and 99.31 ± 1.009 for benazepril hydrochloride and hydrochlorothiazide respectively.

The two proposed methods were simple, precise, sensitive and could be successfully applied for the determination of pure, laboratory made mixtures and pharmaceutical dosage forms. The results obtained were compared with those obtained by A 1%.  相似文献   

13.
A simple high-performance liquid chromatographic (HPLC) method was developed and validated for the quantification of mizoribine in human serum. After the addition of 70% perchloric acid and 3-methylxanthine (50 microg/mL, internal standard) to human serum, the samples were mixed and centrifuged at 12,000 rpm (1432 g) for 10 min. The supernatant was injected onto a C(18) column eluted with a mobile phase of 20 mm Na2HPO4 and methanol (93:7, v/v, pH 3) containing 0.04% octanesulfonic acid and detected utilizing an ultraviolet detector at 275 nm. The linear calibration curve was obtained in the concentration range of 0.1-4.0 microg/mL and the lower limit of quantification was 0.1 microg/mL. This method was validated with selectivity, linearity, precision and accuracy. In addition, the method was successfully applied to estimate the pharmacokinetic parameters of mizoribine in Korean subjects following an oral administration of 100 mg mizoribine (two Bredinine 50 mg tablets). The maximum serum concentration (C(max)) of 2.30 +/- 0.83 microg/mL was reached 2.27 +/- 0.66 h after an oral dose. The mean AUC(0-12 h) and the elimination half-life (t(1/2)) were 13.2 +/- 4.79 microg h/mL and 3.10 +/- 0.74 h, respectively.  相似文献   

14.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of hydrochlorothiazide (I), a common diuretic and anti-hypertensive agent. The analyte and internal standard, tamsulosin (II) were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reversed-phase column (Waters symmetry C18) with a mobile phase of 10 mm ammonium acetate-methanol (15:85, v/v). The protonated analyte was quantitated in negative ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 296.1 solidus in circle 205.0 and m/z 407.2 solidus in circle 184.9 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.5-200 ng/mL for hydrochlorothiazide in human plasma. The lower limit of quantitation was 500 pg/mL, with a relative standard deviation of less than 9%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.5 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

15.
A micellar liquid chromatographic (MLC) procedure was developed for the clinical monitoring of imipramine and its active metabolite, desipramine. The determination of these highly hydrophobic substances was carried out after direct injection of the serum samples using a mobile phase composed of 0.15 m SDS--6% (v/v) pentanol buffered at pH 7, pumped at 1.5 mL/min into a C(18) column (250 x 4.6 mm), and electrochemical detection at 650 mV. Using this MLC method, calibration was linear (r > 0.995) and the limits of detection (ng/mL) were 0.34 and 0.24 for imipramine and desipramine, respectively. Repeatabilities and intermediate precision were tested at three different concentrations in the calibration range and a CV (%) below 2.2 was obtained. In this MLC procedure, the serum is determined without treatment, thus allowing repeated serial injections without changes in retention factors, and reducing the time and consumables required to carry out the pretreatment process. The assay method can be applied to the routine determination of serum imipramine and its metabolite in therapeutic drug monitoring.  相似文献   

16.
A new, specific, and sensitive RP-HPLC method was developed for the simultaneous determination of eprosartan (EPR) and hydrochlorothiazide (HCT). Good chromatographic separation was achieved using a 250 x 4.6 mm id, 5 microm particle size Symmetry C18 column. The mobile phase acetonitrile-0.1 M phosphate buffer (35+65, v/v), pH 4.5, was pumped at a flow rate of 1 mL/min, with UV detection at 275 nm. The method showed good linearity in the ranges of 0.5-50 and 0.1-10 microg/mL, with LOD of 0.06 and 0.02 microg/mL and LOQ of 0.20 and 0.08 microg/mL for EPR and HCT, respectively. The proposed method was successfully applied for the analysis of the studied drugs in their synthetic mixture and co-formulated tablets. The method was further extended to the in vitro and in vivo determination of the two drugs in spiked and real human plasma. Interference likely to be encountered from the co-administered drugs was studied.  相似文献   

17.
An ultrafast liquid chromatographic bioanalytical method was developed and validated for the determination of vilazodone in Wistar rat serum. Principles of quality by design were implemented for enhancing the bioanalytical liquid–liquid extraction of vilazodone from rat serum. A Box–Behnken design was utilized in the studies by selecting extraction time, centrifugation speed, and vortex time as the critical method variables for evaluating their effect on the analytical attribute, i.e., %recovery of vilazodone. Chromatographic separation was achieved within a run time of 10?min using a C-18 column and mobile phase comprising of methanol:phosphate buffer of pH 7 (85:15 v/v) flowing at 1.5?mL/min. Photodiode array detection was performed at 242?nm. Results of validation studies were satisfactory. The method was linear over a concentration of 100–2,000?ng/mL with acceptable accuracy and precision. Limits of detection and quantitation for the developed method were 50 and 100?ng/mL, respectively. This QbD-based approach was found suitable for routine bioanalysis of vilazodone in the biological matrix.  相似文献   

18.
A new, simple, precise and rapid high performance liquid chromatographic method was developed for the determination of meropenem in human serum, urine and pharmaceutical dosage forms. Chromatography was carried out on an LC(18) column using a mixture of 15 mM KH(2)PO(4):acetonitrile:methanol (84:12:4; v/v/v), adjusted to pH 2.8 with H(3)PO(4). The proposed method was conducted using a reversed-phase technique, UV monitoring at 307.6 nm and cefepime as an internal standard. The retention times were 5.98 and 7.47 min for cefepime and meropenem, respectively. The detector response was linear over the concentration range of 50-10,000 ng/mL. The detection limit of the procedure was found to be 22 ng/mL. The detection limit for meropenem in human plasma was 108.4 ng/mL and the corresponding value in human urine was 179.3 ng/mL. No interference from endogenous substances in human serum, urine and pharmaceutical preparation was observed. The proposed method is sufficiently sensitive for determination of the concentrations of meropenem and may have clinical application for its monitoring in patients receiving the drug.  相似文献   

19.
A direct, accurate, and sensitive chromatographic analytical method for the quantitative determination of five fluoroquinolones (enoxacin, ofloxacin, norfloxacin, ciprofloxacin, and enrofloxacin) in chicken whole blood is proposed in the present study. For quantitative determination lamotrigine was used as internal standard at a concentration of 20 ng/microL. The developed method was successfully applied to the determination of enrofloxacin, as the main component of commercially available veterinary drugs. Fluoroquinolone antibiotics were separated on an Inertsil (250 x 4 mm) C8, 5 microm, analytical column, at ambient temperature. The mobile phase consisted of a mixture of citric acid (0.4 mol L(-1))-CH3OH-CH3CN (87:9:4% v/v) leading to retention times less than 14 min, at a flow rate 1.4 mL min(-1). UV detection at 275 nm provided limits of detection of 2 ng/mL per 20 microL injected volume for enoxacin, norfloxacin, and ciprofloxacin, 0.4 ng/mL for ofloxacin, and 4 ng/mL for enrofloxacin. Preparation of chicken blood samples is based on the deproteinization with acetonitrile while the pharmaceutical drug was simply diluted with water. Peaks of examined analytes in real samples were identified by means of a photodiode array detector. The method was validated in terms of within-day (n=6) precision and accuracy after chicken whole blood sample deproteinization by CH3CN. Using 50 microL of chicken blood sample, recovery rates at fortification levels of 40, 60, and 80 ng ranged from 86.7% to 103.7%. The applicability of the method was evaluated using real samples from chicken under fluoroquinolone treatment.  相似文献   

20.
The aims were to develop a liquid chromatographic (LC) method with ultraviolet detection (UVD) for O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) O-oximes of common aldehydes and ketones, and to define the steric limits of the synthetic reaction used to make the PFBHA O-oxime standards for gas chromatographic (GC) and LC methods. Ten new O-oximes were synthesized with the new optimized method, and their purities were demonstrated by GC/electron-capture detection (ECD), GC/mass spectrometry (MS), ultraviolet spectroscopy, infrared spectroscopy, and proton and 13C-nuclear magnetic resonance spectroscopy. Ketones substituted at both beta-carbons relative to the carbonyl carbon, like diisobutyl ketone and 2,4-hexanedione, showed lower synthetic yields by wet chemistry methods. A new C18 reverse-phase LC method with UVD at 200 nm and acetonitrile-water in both the isocratic and gradient-elution modes was then developed to sensitively resolve a mixture of 13 pure PFBHA O-oximes. The detection limit was near 100 ng O-oxime/mL or about 14-50 ng aldehyde/mL and the least quantifiable limits were near 500 ng/mL or about 70-250 ng aldehyde/mL, with lower limits for glyoxal, methylglyoxal, benzaldehyde, and acetophenone. Carbonyl compounds in 500 mL water samples were then determined in distilled water and tap water by gradient elution. Vapors of n-valeraldehyde and acrolein generated in gas bags at concentrations near occupational guidelines were also sampled, desorbed, and then determined by either isocratic or gradient elution at 200 or 254 nm within 30-45 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号