首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Building standards incorporating quantitative acoustical criteria to ensure adequate sound insulation are now being implemented. Engineers are making great efforts to design acoustically efficient double-wall structures. Accordingly, efficient simulation models to predict the acoustic insulation of double-leaf wall structures are needed. This paper presents the development of a numerical tool that can predict the frequency dependent sound reduction index R of stud based double-leaf walls at one-third-octave band frequency range. A fully vibro-acoustic 3D model consisting of two rooms partitioned using a double-leaf wall, considering the structure and acoustic fluid coupling incorporating the existing fluid and structural solvers are presented. The validity of the finite element (FE) model is assessed by comparison with experimental test results carried out in a certified laboratory. Accurate representation of the structural damping matrix to effectively predict the R values are studied. The possibilities of minimising the simulation time using a frequency dependent mesh model was also investigated. The FEA model presented in this work is capable of predicting the weighted sound reduction index Rw along with A-weighted pink noise C and A-weighted urban noise Ctr within an error of 1 dB. The model developed can also be used to analyse the acoustically induced frequency dependent geometrical behaviour of the double-leaf wall components to optimise them for best acoustic performance. The FE modelling procedure reported in this paper can be extended to other building components undergoing fluid–structure interaction (FSI) to evaluate their acoustic insulation.  相似文献   

2.
A field study has been carried out in urban Assiut city, Egypt. The goals of this study are: (1) to carry out measurements to evaluate road traffic noise levels, (2) to determine if these levels exceeds permissible levels, (3) to examine people’s attitudes towards road traffic noise, (4) to ascertain the relationship between road traffic noise levels and degree of annoyance. The measurements indicate that traffic noise noise levels are higher than those set by Egyptian noise standards and policy to protect public health and welfare in residential areas: equivalent continuous A - weighted sound pressure levels (LA eq) = 80 dB and higher were recorded, while maximum permissible level is 65 dB. There is a strong relationship between road traffic noise levels and percentage of highly annoyed respondents. Higher road traffic noise levels mean that the percentage of respondents who feel highly annoyed is also increased.  相似文献   

3.
The study reports on the relevancy and accuracy of using mobile phones in participatory noise pollution monitoring studies in an urban context. During one year, 60 participants used the same smartphone model to measure environmental noise at 28 different locations in Paris. All measurements were performed with the same calibrated application. The sound pressure level was recorded from the microphone every second during a 10-min period. The participants frequently measured the evolution of the sound level near two standard monitoring sound stations (in a square and near a boulevard), which enables the assessment of the accuracy and relevancy of collected acoustic measurements. The instantaneous A-weighting sound level, energy indicators such as LA,eq, LA10, LA50 or LA90 and event indicators such as the number of noise events exceeding a certain threshold Lα (NNEL ? Lα) were measured and compared with reference measurements. The results show that instantaneous sound levels measured with mobile phones correlate very well (r > 0.9, p < 0.05) with sound levels measured with a class 1 reference sound level meter with a root mean square error smaller than 3 dB(A). About 10% of the measurements for the boulevard location (respectively 20% for the square) were inaccurate (r < 0.3, p < 0.05). Nevertheless, mobile phone measurements are in agreement for the LA50 and the LA90 acoustic indicators with the fixed station (4-m high) measurements, with a median deviation smaller than 1.5 dB(A) for the boulevard (respectively 3 dB(A) for the square).  相似文献   

4.
Traffic noise attenuation at different 1/3-octave frequencies is measured at three vegetation sites and a control site in Delhi, the capital city of India. The study indicates that attenuation generally increases with frequency. At low frequencies, maxima (between 10 and 16 dB) in relative attenuation are observed in the frequency interval between 315 and 400 Hz. Comparatively greater relative attenuation (>20 dB) is observed in the high frequency range between 10 and 12.5 kHz. A significantly higher relative attenuation of more than 24 dB is observed characteristically at 3.15 kHz at all the vegetation sites. The results indicate that vegetation belts could be used as effective barriers for traffic noise control along the roadsides.  相似文献   

5.
In some cases an impulsive noise source such as a gunshot can be a preferred alternative when investigating building acoustics, including sound insulation measurements, when compared to conventional steady state noise sources. A gun equipped with blank cartridges is an impulsive noise source that is lightweight and small enough to be easily transported. The differences in the noise characteristics between individual cartridges for the same gun are usually small, so the impulsive source can be replicated to a high degree. This paper is focused on the practical application of the sound exposure levels produced by a gunshot with a known sound energy level in the rooms under investigation. In this way, the equipment and methods required by the conventional method are simplified significantly. Furthermore, reverberation times need not be measured, since the equivalent absorption area can be directly obtained from the measured sound exposure levels. Using Green’s theorem, the roles of the sound source and measuring microphone were exchanged, which simplified the determination of sound insulation as it was easier to change the position of the gun than the microphone. The results obtained using the impulsive noise source were in good agreement with those obtained using the conventional method. Above 100 Hz, their difference in any frequency band of interest was less than 1 dB.  相似文献   

6.
Access to quiet areas in cities is important to avoid adverse health effects due to road traffic noise. Most urban areas which are or can become quiet (LA,eq < 45 dB) are shielded from direct road traffic noise. By transfer paths over roof level, many road traffic noise sources contribute to the level in these shielded areas and noise abatement schemes may be necessary to make these areas quiet. Two real life shielded courtyards in Göteborg have been selected as reference cases for a numerical investigation of noise abatement schemes. The selected areas are modelled as canyons with a road traffic noise source modelled outside the canyon by a finite incoherent line source, which is more realistic than both a coherent and an incoherent line source of infinite length. The equivalent sources method has been used for the calculations. For all studied noise abatement schemes in the shielded canyon, the reductions are largest for the lower canyon observer positions. Façade absorption is the most effective when placed in the upper part of the canyon and can typically yield a reduction of 4 dB(A). Constructing 1 m wide walkways with ceiling absorption reduces the level typically by 3 dB(A). These effects are most effective for narrower canyons. For treatments at the canyon roof, reductions are independent of the canyon observer position and amount to 4 dB(A) for a 1 m tall screen and 2 dB(A) for a grass covering of a saddle roof. Downward refracting conditions increase the levels for the lower canyon observer positions and higher frequencies. For sources located in canyons, abatement schemes therein are more effective for noise reduction in the shielded canyon than similar abatement schemes in the shielded canyon itself, given that all contributing source canyons are treated.  相似文献   

7.
Y. Simard  R. Lepage 《Applied Acoustics》2010,71(11):1093-1098
The impact of shipping noise on marine life and quality of marine mammal habitats in oceans and coastal environments has become a major concern worldwide. Background noise can also limits detection of marine mammal sounds in passive acoustic monitoring (PAM) systems. Characterisation of this noise over long time periods and estimates of the exposure of the different marine mammal groups are still very fragmentary and limited to only a few locations. This paper presents such observations for a part of a busy seaway of North America, the St. Lawrence Seaway, which cuts through the Gulf of St. Lawrence and crosses several cetaceans and pinnipeds feeding areas. Noise was continuously recorded for a 5-month period in summer 2005 by an AURAL autonomous hydrophone deployed close to the bottom in the 300-m deep seaway. The maximum received noise level in the 20 Hz-0.9 kHz band reached 136 dB re 1 μParms. The median level of 112 dB re 1 μParms was exceeded 50% of the time due to transiting merchant ships. Median spectral level tracks the reference curve for heavy traffic in oceans and 50% of the noise is within a ±6 dB envelope around it. Strong spectral lines were common at low frequencies and in the 400-800 Hz band. M-weighting functions applied for the three groups of cetaceans and pinnipeds indicate wideband median levels varying from 106 to 112 dB-M re 1 μParms surrounded by a ±5 dB two-quartile interval. Higher values are expected for animals frequenting the sound channel at intermediate depths. As expected, the highest M-weighting levels correspond to low-frequency specialists and pinnipeds. Criteria for assessing the behavioural and physiological impacts of long term exposure of marine mammals to such shipping noise levels need to be worked out.  相似文献   

8.
Nowadays, railway traffic noise is acknowledged to negatively impact the wellbeing of the whole community, particularly in urban environments. Unfortunately, the traditional approach to support decision making in noise reduction intervention seems to start only from the compliance to the regulations in place, rather than from the identification of an optimal trade-off between the cost of the annoyance of the community and the cost of the intervention. An advanced approach is proposed, which starts from any annoyance due to traffic noise, and which aims at identifying an optimal trade-off by means of evaluation of the minimum cost for the whole community. A case study in a railway noise-affected urban cluster of Milan, Italy, has been performed, which is representative of any urban environment affected by traffic noise. The sensitivity analysis on the parameters of the approach (the size of the buildings; the level of railway traffic; the cost per square meter of the acoustic barriers) shows that the results are robust and reliable, and in the specific case a noise reduction of 15–25 dB is optimal for the community.  相似文献   

9.
This work presents sound insulation and sound reflection measurements conducted over sonic crystal noise barriers according to the European standards EN 1793-2, EN 1793-5 and EN 1793-6. In most of the reference literature, sound insulation and reflection properties of sonic crystals are measured or a diffuse sound field or in a direct sound field including the top and side edge diffraction effects together with the transmitted (or reflected) components. The aim of this work is to perform free-field measurements over a real-sized sample in order to window out all diffraction components and to verify the points of strength and weakness of the application of standardised measurements to sonic crystals. Diffuse field measurements in laboratory are also done for comparison purposes. Since the target frequency range for traffic noise spectrum is centred at around 1000 Hz, a finite element based parametric investigation is performed to design unit cells capable of generating band gaps in the one-third octave bands ranging from 800 Hz to 1250 Hz. Then, 3 × 3 m sonic crystal noise barriers are installed in the Laboratory of the University of Bologna and sound insulation and sound reflection measurements are performed according to the mentioned active standards for normal incidence. Sound insulation is measured for diffuse incidence too. The two methods give different results. The method more directly comparable to calculations is the free-field one. However, if on the one hand the application of a time window allows to compute the transmitted or reflected component only, on the other hand the time window itself limits the maximum width of the sample for which all reflections of the n-th order having a significant spectral content are included, and thus results critical in the analysis of this kind of noise barriers. Nevertheless, the standardised measurements allow a direct comparison between the performance of sonic crystals and common noise barriers.  相似文献   

10.
The performance of a transformer core may be considered in terms of power loss and by the noise generated by the core, both of which should be minimised. This paper discusses the setting up of a suitable system for evaluation of noise in a large model transformer core (500 kV A) and issues associated with noise measurement. The equivalent continuous sound pressure level (LAeq) was used as a measure of the A-weighted sound level and measurements were made in the range 16 Hz–25 kHz for various step lap core configurations. The selection of optimum sound insulation materials between core and ground support and for enclosing the transformer is essential for minimisation of background noise. Core clamping pressure must be optimised in order to minimise noise. The use of two laminations per layer instead of one leads to an increase in noise arising from the core. Provided care is taken in building the core, good reproducibility of results can be obtained for analysis.  相似文献   

11.
高效共振混合机工作频率为60 Hz,且系统处于共振,产生较大低频噪声。针对振动机械产生的有害噪声,分析了高效共振混合机低频高加速度共振混合过程的特点,得到了60 Hz低频声波穿透力强特点,相比传统的以吸声材料构建的50~100 mm厚度、隔声效果小于10 dB的隔声罩,分析了薄膜型声学超材料在低频减振降噪中的隔声特性。通过多物理场仿真分析,60 Hz时隔声量为31.4 dB,确定了硅橡胶弹性薄膜的预应力和质量块的面密度;采用3D打印机快速成型技术,构建了隔声实验装置,分析了独立隔声单元、面密度、薄膜尺寸等隔声特性规律。基于人耳在实际环境中感受到的噪声强度,提出了噪声衰减量和插入损失的分析方法,在距离声源380 mm和1000 mm的位置,60 Hz时隔声量分别为27 dB和38 dB。研究成果丰富了低频隔声特性理论,为薄膜型声学超材料的工程设计和优化提供了技术支撑。  相似文献   

12.
In order to reduce the negative effect on the environment, environmentally friendly materials are being chosen for the construction of buildings more and more frequently. The building materials that are now used more commonly are clay, straw and reeds. The sound insulation properties of these environmentally friendly materials have not yet been examined thoroughly. This paper presents most commonly used sound reduction indexes RW that have been measured in the semi-anechoic chamber and determined during the simulation. It has been found that adobe, pressed straw and reeds (oriented parallel to the sound transmission) are suitable for low-frequency sound insulation. The material with the best sound reduction index was adobe. The sound reduction index RW of a 200 mm thick adobe wall reached up to 43 dB.  相似文献   

13.
The current study investigated the effect of noise on sleep in subjects' own houses using recorded traffic noises. A railway noise and two kinds of road traffic noise differing in level-fluctuations were used as stimuli. Subjects were exposed all night to the artificially controlled stimuli for 10 days through a portable compact disc (CD) player. The effect of noise on sleep was judged in three ways, namely whether the subject had switched off the CD player, a self-declaration of the subject based on a questionnaire, and the amount of arm movement of the subject during the night as measured by an actigraph. The results of the analysis of the self-declaration data showed that the thresholds where sleep disturbance began were 40-45 dB in for road traffic noise and about 35 dB for railway noise, which corresponded to 50-55 dB in LA,Fmax of each train noise event. The results of the analysis of the actigraphy data showed a rapid increase in the incidence of mid-sleep awakening at sound pressure levels higher than 50 dB, for railway noise. However, neither of the road traffic noises showed such a tendency, as long as the sound pressure level was less than 55 dB, .  相似文献   

14.
In Norway, the requirement for structure borne noise from tunnels is LpAFmax = 32 dB inside dwellings. According to the Norwegian Standard 8175 it is expected that up to 20% of the exposed population are disturbed by the noise at this level. However, the scientific basis for this noise limit is poor. The aim of this study was to determine the degree of annoyance and self-reported sleep disturbances as a function of LpAFmax. In the present study, 521 dwellings exposed to structural sound from railway rock-tunnels were identified. A questionnaire was sent to one randomly selected person above 18 years of age from each dwelling. The results showed that both noise induced annoyance and reported sleep disturbances were significantly related to LpAFmax. Other factors that increased the annoyance were high pass-by frequency of freight trains per day, and degree of sound insulation of the windows. At LpAFmax = 32 dB, 20% were slightly or more than slightly annoyed, and 4% were moderately or more than moderately annoyed. According to the pre-existing assumption that up to 20% of the exposed population are disturbed by the noise at this level, the present results give support to the Norwegian noise limit LpAFmax = 32 dB inside dwellings of structure borne noise from railway tunnels.  相似文献   

15.
Fan is one of the main noise sources of the room air-conditioners. Axial flow fans are widely used in the outdoor unit of split type air-conditioners. The interaction between the fan and the heat exchanger should be taken into consideration. However, only a few researches have been carried out on predicting the aeroacoustic noise because of the difficulty in obtaining detailed information of the flow field. This paper is to understand the generation mechanism of sound and to develop a prediction method for the flow field and the acoustic pressure field of the outdoor unit. Acoustic measurement is performed in a semi-anechoic chamber. Effects of each components is analyzed. Based on commercial computational fluid dynamics (CFD) code, Fluent, Fukano’s model is used to predict the overall sound pressure level of broadband noise. The predicted sound pressure levels based on original Fukano’s model are 7.66 dB and 7.42 dB lower than measurement results at 780 rpm and 684 rpm, respectively. And the errors are about 13%. However, when wake width and relative velocity are both calculated by numerical simulations and the distance to blade trailing edge is taken into consideration, the difference of sound pressure level between measurement and prediction is less than 3.4 dB and errors less than 5.5% while the distance is less than 10 mm. Thus, the distance to blade trailing edge should also be an important parameter for Fukano’s model. In comparison with experimental results, it is clearly shown that the Fukano method based on numerical simulation can provide more accuracy than the original Fukano model and numerical results are in a reliable level.  相似文献   

16.
舒珊  杜倩倩  朴勋  李慧 《应用声学》2024,43(2):393-403
滨海公共空间是滨海城市人居环境的重要组成部分,其声环境质量是影响公共空间环境体验的关键因素。本研究以青岛沿海岸线四类滨海公共空间(步道类、广场类、公园类、沙滩类)的声环境为对象,通过问卷调查和实地测量探索滨海公共空间声环境的特征、感知评价及其影响因素。结果表明:(1)滨海公共空间当前环境噪声水平基本不超过国家标准限值55dB(A) ,各类空间声环境客观特征显著不同:公园噪声水平最低,自然声源丰富;广场噪声水平最高,各种城市噪声较多;步道噪声水平较低,但受到交通噪声的影响;沙滩噪声水平较高,但以中低频的海浪声为主,比较稳定。(2)各类滨海公共空间的声源感知以自然声为主,但是广场的自然声源感知较少。此外,声环境的愉悦感评价普遍较高,但在事件感、吵闹度和总体满意度评价上具有显著差异:沙滩声环境总体评价最好,其次是公园,广场和步道的声环境则亟待改善。(3)交通噪声和最大声级Lmax对声环境的负面影响最为显著,此外受访者年龄也是影响滨海公共空间声环境感知评价的关键因素。研究结论可以为滨海公共空间声环境的优化设计提供理论依据。  相似文献   

17.
To clarify the relationship between traffic noise and insomnia, the authors conducted a survey and measured the actual sound level of noise in an urban area. Questionnaires were distributed to adult women who lived within 150 m from two major roads and were completed by 648 of the 1286 subjects (50.4%). The area was divided into three zones according to distance from the road (more than 50, 20-50 and 0-19.9 m). Fifty-seven subjects (8.8%) were classified as having insomnia. Average values of sound level at distances of 20, 50, and 100 m from the major road were Leq 64.7, 57.1, and 51.8 dBA, respectively. Overall, there were no significant differences among the three zones in the prevalence of insomnia and no association between distance from the road and insomnia. However, the result from a sub-data set of the subjects who lived in the areas that showed decreasing noise level as the distance from the main road increased showed that distance from the road was associated with insomnia. This study suggests that researchers should consider the actual traffic situation and its sound level in epidemiological studies about the effects of traffic noise on insomnia.  相似文献   

18.
Plasma actuators were used in this work to control flow-induced broadband noise radiated from a bluff body. The model consists of a cylinder and a component (torque link) that is installed on the lee side of the cylinder. The objective is to reduce the broadband noise mainly generated through the impingement of the cylinder wake on the torque link. The flow-structure interactions between the cylinder wake and the torque link are reduced by manipulating the cylinder wake with the externally imposed body force from the plasma actuators, which lead to the attenuation of the broadband noise. The control performance with the plasma actuators is studied in an anechoic chamber facility by examining far-field sound level and near-field acoustic source changes. At a free stream speed of 30 m/s, corresponding to the Reynolds number of 2.1×105, far-field measurements suggested that a reduction of up to 3.2 dB in overall sound pressure level. The near-field beamforming results also show approximately 3 dB reduction in the interested frequency ranges. The physical mechanisms related to broadband noise control were also discussed. This work suggests that plasma actuators offer the potential for solving flow-induced noise control problem at broadband frequencies.  相似文献   

19.
Pass-by noise from high-speed trains is one important area that has to be handled in all new train projects. For the new line between Oslo and the Gardemoen Airport which opened in 1998, very stringent requirements were set out regarding external noise. To reach the target it was decided that the train should be equipped with wheel dampers. Two different types of wheel dampers were used on the train; a ring damper was mounted on the wheels of the driven bogies, whilst plate dampers divided into tuned absorber fins were mounted on the wheels of the trailer bogies.During the type testing of the Airport Express Train, additional measurements were performed in order to evaluate the acoustic effect of the plate wheel dampers. Two test series were performed with the same train set; first with the train in standard configuration and secondly with the wheel dampers removed from the second and third bogie. The external noise was measured at 5 and 25 m distance from the centre of the track at speeds ranging from 80 to 200 km/h. The third-octave filtered time histories were analyzed to calculate the effect of the wheel dampers. As expected, there was a significant reduction of 4-6 dB at frequencies above 2000 Hz, but there was also a reduction of 2 dB for frequencies as low as 800 Hz. This reduction was also found in the parts of the time histories when the rail should be dominating. This implies that the wheel dampers also reduce the rail noise. The total rolling noise reduction for the trailer bogie was 3 dB at 200 km/h and 1 dB at 80 km/h. From comparison with TWINS-calculated sound power levels it was estimated that the wheel noise would be reduced by 5 dB and the rail noise would be reduced by 1 dB at 200 km/h.  相似文献   

20.
An experimental investigation to determine the noise reduction efficiency of a number of combinations of vehicle mounted noise skirts and trackside low barriers has been carried out. A 1:4-scale mock-up of the German BR185 locomotive was built. Special care was taken to achieve a realistic representation of the wheel/rail sources, using rotating acoustic source wheels able to imitate the radiation from structural modes and acoustic rail ducts with independently adjustable vertical and lateral slots. The acoustic insertion loss (IL) equivalent to a full-scale microphone position at 25 m distance from the track was determined for the different source components separately. The total IL was obtained from sound power spectra calculated with the TWINS software. Results for the design speed (v=120 km/h) and a case with a lower speed (v=100 km/h) are presented to illustrate the effect of speed on the acoustic IL. The tests were performed in open-air free field conditions. The experimental procedure used in the present investigation gives detailed information on the relative contributions from different source components, which is valuable for further design studies. For the eight combinations reported here, the overall reduction achieved was in agreement with results in the literature. The IL was 2-3 dB(A) for cases with only vehicle skirts and the case with only low track barriers. The combined configurations had insertion losses of 7-13 dB(A).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号