首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A vortex-assisted dispersive micro-solid-phase extraction procedure using a new and green sorbent was developed as a simple, fast, and efficient sample preparation method for the extracting five pesticides in several fruit juice samples. In this study, for the first time, riboflavin was used as an efficient sorbent. A few milligrams of riboflavin was directly added into the aqueous solution containing the analytes to adsorb them. After adsorption the analytes, they were desorbed and more concentrated by a dispersive liquid–liquid microextraction procedure. The influence of several effective parameters such as amount of riboflavin, pH, vortex time, eluent nature and volume, and extraction solvent type and volume on the extraction efficiency was investigated. In optimal conditions, linear ranges of the calibration curves were broad. The limits of detection and quantification were attained in the ranges of 0.56–1.5  and 1.9–0.52 ng mL−1, respectively. The proposed method demonstrated to be suitable for concurrent extraction of the studied pesticides in various fruit juice samples with high enrichment factors (320–360) and precision (relative standard deviation ≤7.8% for intra- [n = 6] and interday [n = 4] precisions at a concentration of 25 ng mL−1 of each pesticide).  相似文献   

2.
In this work, performance of a molecularly imprinted polymer (MIP) as a selective solid‐phase microextraction sorbent for the extraction and enrichment of tramadol in aqueous solution and rabbit brain tissue, is described. Binding properties of MIPs were studied in comparison with their nonimprinted polymer (NIP). Ten milligrams of the optimized MIP was then evaluated as a sorbent, for preconcentration, in molecularly imprinted solid‐phase microextraction (MISPME) of tramadol from aqueous solution and rabbit brain tissue. The analytical method was calibrated in the range of 0.004 ppm (4 ng mL−1) and 10 ppm (10 μg mL−1) in aqueous media and in the ranges of 0.01 and 10 ppm in rabbit brain tissue, respectively. The results indicated significantly higher binding affinity of MIPs to tramadol, in comparison with NIP. The MISPME procedure was developed and optimized with a recovery of 81.12–107.54% in aqueous solution and 76.16–91.20% in rabbit brain tissue. The inter‐ and intra‐day variation values were <8.24 and 5.06%, respectively. Finally the calibrated method was applied for determination of tramadol in real rabbit brain tissue samples after administration of a lethal dose. Our data demonstrated the potential of MISPME for rapid, sensitive and cost‐effective sample analysis.  相似文献   

3.
A sensitive and straightforward liquid–liquid–liquid microextraction method was developed to preconcentrate and cleanup antidepressants, including mirtazapine, venlafaxine, escitalopram, fluoxetine, and fluvoxamine, from biological samples before analyzing with high-performance liquid chromatography. The essential novelty of this study is using magnetic ionic liquids as the extraction phase in the lumen of hollow fiber and preparing a liquid magnetic stir bar. In this method, polypropylene hollow fiber was utilized as the permeable membrane for the analyte extraction. Six magnetic ionic liquids consisting of the transition metal and rare earth compounds were synthesized and then hollow fiber lumen was injected as acceptor phase to extract the antidepressants. Besides, 3-pentanol as a water-immiscible solvent was impregnated in the hollow fiber wall pores. The effective factors in the method were optimized with the central composition design. The resultant calibration curves were linear over the concentration range of 0.8–400.0 ng mL−1 (R2 ≥ 0.996). The method displayed the proper detection limit (0.11–0.24 ng mL−1), the reasonable limit of quantification (≤0.79 ng mL−1), wide linear ranges, high preconcentration factors (≥294.3), and suitable relative standard deviation (2.31–5.47%) for measuring antidepressant medications. Analysis of human milk and urine samples showed acceptable recoveries of 96.5–103.8% with excellent relative standard deviations lower than 5.95%.  相似文献   

4.
A new sample preparation method based on microextraction in packed syringe was developed for preconcentration of quercetin prior to its spectrophotometric determination. Molecularly imprinted polymers as packing material was used for higher extraction efficiency. First, glass powder as support material because of low cost and available substrate was modified, and then molecularly imprinted polymers were synthesized by the sol–gel method using 3-aminopropyltriethoxysilane as a functional monomer and tetraethyl orthosilicate as cross-linker agent. The combination of a molecularly imprinted polymers and microextraction in packed syringe increased the selectivity and sensitivity. The surface morphology and functionality of the prepared molecularly imprinted polymers was characterized using Fourier-transform infrared spectroscopy, Field emission scanning electron microscopy, energy dispersive X-ray spectroscopy, and thermogravimetric analysis. Different influencing parameters on extraction efficiency such as effect of the number of sample sorption/desorption cycles, type and volume of desorption solvent, pH of the sample solution, and molecularly imprinted polymers amounts were optimized. Under the optimum condition, the proposed method displayed a linear range from 0.01 to 5 µg mL−1 and limit of detection 3.68 ng mL−1. Relative standard deviation for three replicate determination of 1 µg mL−1 quercetin was 2.1 %. The proposed method was applied successfully for the selective extraction of quercetin from tea and coffee samples.  相似文献   

5.
An anti-ketamine molecularly imprinted polymer (MIP) was synthesized and used as the sorbent in a solid-phase extraction protocol to isolate ketamine and norketamine from human hair extracts prior to LC-MS/MS analysis. Under optimised conditions, the MIP was capable of selectively rebinding ketamine, a licensed anaesthetic that is widely misused as a recreational drug, with an apparent binding capacity of 0.13 μg ketamine per mg polymer. The limit of detection (LOD) and lower limit of quantification (LLOQ) for both ketamine and norketamine were 0.1 ng/mg hair and 0.2 ng/mg hair, respectively, when 10 mg hair were analysed. The method was linear from 0.1 to 10 ng/mg hair, with correlation coefficients (R 2) of better than 0.99 for both ketamine and norketamine. Recoveries from hair samples spiked with ketamine and norketamine at a concentration of 50 ng/mg were 86% and 88%, respectively. The method showed good intra- and interday precisions (<5%) for both analytes. Minimal matrix effects were observed during the LC-MS/MS analysis of ketamine (ion suppression −6.8%) and norketamine (ion enhancement +0.2%). Results for forensic case samples demonstrated that the method successfully detected ketamine and norketamine concentrations in hair samples with analyte concentrations ranging from 0.2 to 5.7 ng/mg and from 0.1 to 1.2 ng/mg, respectively.  相似文献   

6.
Senkyunolide I is one of the major bioactive components in the herbal medicine Ligusticum chuanxiong. The aim of this study was to develop and validate a fast, simple and sensitive LC‐MS/MS method for the determination of senkyunolide I in dog plasma. The plasma samples were processed with acetonitrile and separated on a Waters Acquity UPLC BEH C18 column (50 × 2.1 mm, 1.7 μm). The mobile phase consisted of 0.1% formic acid aqueous and acetonitrile was delivered at a flow rate of 0.3 mL min−1. The detection was achieved in the positive selected reaction monitoring mode with precursor‐to‐product transitions at m/z 225.1 → 161.1 for senkyunolide I and at m/z 349.1 → 305.1 for an internal standard. The assay was linear over the tested concentration range, from 0.5 ng mL−1 to 1000 ng mL−1, with a correlation coefficient >0.9992. The mean extraction recovery from dog plasma was within the range of 85.78–93.25%, while the matrix effect of the analyte was within the range of 98.23–108.89%. The intra‐ and inter‐day precisions (RSD) were <12.12% and the accuracy (RR) ranged from 98.89% to 104.24%. The validated assay was successfully applied to pharmacokinetic and bioavailability studies of senkyunolide I in dogs. The results demonstrated that (a) senkyunolide I showed short elimination half‐life (<1 h) in dog, (b) its oral bioavailability was >40% and (c) senkyunolide I showed dose‐independent pharmacokinetic profiles in dog plasma over the dose range of 1–50 mg kg−1.  相似文献   

7.
A reliable, high‐throughput and sensitive LC–MS/MS procedure was developed and validated for the determination of five tyrosine kinase inhibitors in human plasma. Following their extraction from human plasma, samples were eluted on a RP Luna®‐PFP 100 Å column using a mobile phase system composed of acetonitrile and 0.01 m ammonium formate in water (pH ~4.1) with a ratio of (50:50, v /v) flowing at 0.3 mL min−1. The mass spectrometer was operating with electrospray ionization in the positive ion multiple reaction monitoring mode. The proposed methodology resulted in linear calibration plots with correlation coefficients values of r 2 = 0.9995–0.9999 from concentration ranges of 2.5–100 ng mL−1 for imatinib, 5.0–100 ng mL−1 for sorafenib, tofacitinib and afatinib, and 1.0–100 ng mL−1 for cabozantinib. The procedure was validated in terms of its specificity, limit of detection (0.32–1.71 ng mL−1), lower limit of quantification (0.97–5.07 ng mL−1), intra‐ and inter assay accuracy (−3.83 to +2.40%) and precision (<3.37%), matrix effect and recovery and stability. Our results demonstrated that the proposed method is highly reliable for routine quantification of the investigated tyrosine kinase inhibitors in human plasma and can be efficiently applied in the rapid and sensitive analysis of their clinical samples.  相似文献   

8.
This paper report a novel strategy for synthesis and application of CuS@ZnS@Fe3O4‐CNTs composite which has great potentials as artificial receptor for tartrazine trapping due to its ultrahigh surface area and functionality which is related to application of electrochemical route. A durable and economical pipette‐tip CuS@ZnS@Fe3O4‐CNTs nano‐composite miniaturized solid phase extraction coupled with UV‐Vis spectrophotometry was developed for clean‐up and determination of tartrazine from various water samples. Undoubtedly, presence of mild‐intensity/frequency ultrasound irradiation played a key role for reducing consumption of eluent volume by broking hydrogen bonds between retained analyte and sorbent. The influence of factors including pH, sorbent dosage, sonication time and eluent volume were investigated and optimum conditions were obtained using experimental design methodology. Under optimized conditions, good extraction efficiencies for the analyte were obtained with no matrix interference in the subsequent UV‐Vis. Good linearity for tartrazine in the range of 20‐5000 ng mL‐1 with correlation coefficients of R2 ≥ 0.99 and low detection limit close to 4.76 ng mL‐1 reveals high applicability of method for trace analysis.  相似文献   

9.
The aim of this work was to develop an efficient method for the selective extraction and analysis of fenoxycarb, a carbamate pesticide, in mussel samples using a molecularly imprinted solid‐phase extraction device. The optimization of molecularly imprinted polymer synthesis was performed using the experimental design under the response surface methodology approach. A fast rebinding study and Freundlich isotherm adsorption were carried out to calculate binding capacity B, site number n, and affinity constant Kf. The optimum molecularly imprinted polymer was successfully used as sorbent of a solid‐phase extraction cartridge for the determination of fenoxycarb in real mussel samples. The range of linearity was 0.3–30 mg/L with a correlation coefficient of 0.991. The limit of detection was 0.247 mg/kg. The recovery of fenoxycarb extracted from mussel samples of Mediterranean sea was 97% (n = 3) with relative standard deviation between 6 and 7% proving the reliability of the developed method.  相似文献   

10.
A molecularly imprinted polymer was synthesized and applied as a sorbent in the solid‐phase extraction device. The imprinted polymer was characterized by fourier‐transform infrared spectroscopy and scanning electron microscope. The results revealed that imprinted polymer possess sensitive selectivity and reliable adsorption properties for five NSAIDs. The imprinted polymer was successfully applied to the pre‐concentration for five NSAIDs in different water samples prior to UPLC‐MS/MS. In the early studies, several factors were investigated, including pH adjustment, the kind of elution solvent and the volume of elution solvent. Finally, we found that the pH 5 and an aliquot of 2 mL methanol were suitable for the water samples. The limits of detection and limits of quantitation of five nonsteroidal anti‐inflammatory drugs varied from 0.007 to 0.480 μg L−1 and 0.03 to 1.58 μg L−1, respectively. The spiking recoveries of the target analytes were 50.33‐127.64% at the levels of 0.2 μg L−1, 2 μg L−1 and 5 μg L−1. The precision and accuracy of this method showed a great increase compared with traditional solid‐phase extraction. The developed method was successfully applied to extraction and analysis of NSAIDs in different water samples with satisfactory results which could help us better understand their environmental fate and risk to ecological health.  相似文献   

11.
Electrospun nanofibers from poly(methylmethacrylate) (PMMA) and polystyrene (PS) blend were used as a sorbent to extract tramadol from urine and plasma samples. Then, the tramadol concentration was determined by corona discharge ion mobility spectrometry. The hydrophilic (PMMA) and hydrophobic (PS) properties of the blend polymer improved extraction efficiency of the analyte. The scanning electron microscopy images of the PMMA/PS nanofibers showed a diameter range of 130–600 nm with a smooth morphology. Parameters affecting extraction efficiency were optimized and under the optimized conditions, the dynamic ranges and detection limit of tramadol were found to be 30–500 and 10–200 ng mL?1, and 9.4 and 1.6 ng mL?1 in plasma and urine samples, respectively.  相似文献   

12.
A convenient, selective and sensitive liquid chromatographic-electrospary ionization mass spectrometry (LC–ESI–MS) method was developed and validated to determine lovastatin in human plasma. The analyte was extracted from human plasma samples by typical liquid–liquid extraction, separated on a C18 column by using the mobile phase consisting of water–methanol (13:87, v/v). Simvastatin was used as the internal standard (IS). The method was linear within the range of 0.1–20 ng mL−1. The lower limit of quantification (LLOQ) was 0.1 ng mL−1. The intra- and inter-run precision, calculated from quality control (QC) samples was less than 10.2%. The accuracy as determined from QC samples was in the range of 99.3–102.9% for the analyte. The mean recoveries for lovastatin and IS were 84.8 and 88.0%, respectively. The method was successfully applied for evaluation of the pharmacokinetic of lovastatin in healthy volunteers.  相似文献   

13.
In this work, molecularly imprinted nanoparticles (MINPs) were applied as selective adsorbent for ultrasound‐assisted micro‐solid‐phase extraction (UAMSPE) of doxepin (DP) from human plasma samples, which was then cleaned up, pre‐concentrated and subjected to HPLC. The MINPs were synthesized based on a non‐covalent approach by precipitation polymerization utilizing methacrylic acid and styrene as functional monomers, DP as template, ethylene glycol dimethacrylate as cross‐linker and 2,2‐azobisisobutyronitrile (AIBN) as initiator. The obtained MINPs were characterized by Fourier transform‐infrared and field emission scanning electron microscopy. Factors influencing the efficiency of UAMSPE such as sonication time, volume of eluent solvent and amount of sorbent were investigated using a central composite design and the optimal points were identified as 4 min of sonication time, 380 μL of eluent solvent and 30 mg of sorbent. Under optimized conditions, the proposed method has linear responses in the range of 0.2–2000 ng mL–1, with a satisfactory limit of detection of 0.04 ng mL–1 and limit of quantification of 0.11 ng mL–1.  相似文献   

14.
The sublingual combination of buprenorphine and naloxone (Suboxone®) and Methadone Maintenance Therapy have been found effective in treating heroin addiction. A new analytical method suitable for the simultaneous determination of buprenorphine, norbuprenorphine, methadone and naloxone in human plasma by means of liquid chromatography with coulometric detection has been developed. The chromatographic separation was achieved with a phosphate buffer–acetonitrile mixture as the mobile phase on a cyano column. The monitoring cell of the coulometric detector was set at an oxidation potential of +0.600 V. A rapid clean-up procedure of the biological samples using a microextraction by packed sorbent technique has been implemented, employing a C8 sorbent inserted into a syringe needle. The extraction yield values were satisfactory for all analytes (>85%). The calibration curves were linear over a range of 0.25–20.0 ng mL−1 for buprenorphine and norbuprenorphine, 3.0–1000.0 ng mL−1 for methadone and 0.13–10.0 ng mL−1 for naloxone. The sensitivity was also high with limits of detection of 0.08 ng mL−1 for both buprenorphine and norbuprenorphine, 0.9 ng mL−1 for methadone and 0.04 ng mL−1 for naloxone. The intraday and interday precision data were always satisfactory.The method was successfully applied to plasma samples obtained from former heroin addicts treated with opioid replacement therapy.  相似文献   

15.
Guanidinoacetate methyltransferase deficiency is a recently discovered inborn defect of creatine biosynthesis which reduces serum creatinine concentrations to as low as 0.58 μg mL−1 (or 0.00058 μg mL−1 after 1,000-fold dilution). To measure ultra trace levels of creatinine in diluted samples, molecularly imprinted solid-phase extraction (MISPE) and molecularly imprinted polymer (MIP) sensor techniques have been found to be inadequate. A combination of these techniques (i.e. MISPE hyphenated with use of an MIP-sensor), reported in this paper, has been found to be highly suitable for direct assay of creatinine in highly diluted human blood serum without complicated pretreatment of the sample. The proposed technique has the potential to enhance the sensitivity of creatinine measurement from μg mL−1 to ng mL−1 in highly dilute aqueous samples in which the concentrations of interfering constituents are reduced to negligible levels. In this work the sensitivity to creatinine was found to be improved compared with that of the MIP-sensor method alone (limit of detection, LOD, 0.00149 μg mL−1). After preconcentration by MISPE and use of the sensor the detection limit for creatinine was as low as 0.00003 μg mL−1 (RSD = 0.94%, S/N = 3; 50-fold preconcentration factor) in aqueous samples.  相似文献   

16.
A new type of composite material based on carbon nanotubes (CNTs) and sol–gel chemistry was prepared and used as sorbent for needle trap device (NTD). The synthesized composite was prepared in a way to disperse CNTs molecules in a sol–gel polymeric network. CNT/silica composites with different CNT doping levels were successfully prepared, and the extraction capability of each composite was evaluated. Effects of surfactant and the oxidation duration of CNTs on the extraction efficiency of synthesized composites were also investigated. The applicability of the synthesized sorbent was examined by developing a method based on needle trap extraction (NTE) and gas chromatography mass spectrometry detection (GC–MS) for the determination of polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. Important parameters influencing the extraction process were optimized and an extraction time of 30 min at 50 °C and sampling flow rate of 2.5 mL min−1 gave maximum peak area, when NaCl (15%, w/v) was added to the aqueous sample. The linearity for acenaphthene, acenaphthylene and fluorene was in the concentration range of 0.01–20 ng mL−1 and for naphthalene and anthracene was in the range of 0.1–50 ng mL−1. Limits of detection was 0.001 ng mL−1, for acenaphthene, acenaphthylene and fluorene, and 0.01 ng mL−1, for naphthalene and anthracene using time-scheduled selected ion monitoring (SIM) mode, and the RSD% values (n = 3) were all below 11.2% at the 1 ng mL−1 level. The developed method was successfully applied to real water samples while the relative recovery percentages obtained for the spiked water samples were from 73.8 to 113.8%.  相似文献   

17.
A novel molecularly imprinted polymer based on graphene oxide was prepared as a solid‐phase extraction adsorbent for the selective adsorption and extraction of cyromazine from seawater samples. The obtained graphene oxide molecularly imprinted polymer and non‐imprinted polymer were nanoparticles and characterized by scanning electron microscopy. The imprinted polymer showed higher adsorption capacity and better selectivity than non‐imprinted polymer, and the maximum adsorption capacity was 14.5 mg/g. The optimal washing and elution solvents for molecularly imprinted solid phase extraction procedure were 2 mL of acetonitrile/water (80:20, v/v) and methanol/acetic acid (70:30, v/v), respectively. The recoveries of cyromazine in the spiked seawater samples were in the range of 90.3–104.1%, and the relative standard deviation was <5% (n = 3) under the optimal procedure and detection conditions. The limit of detection of the proposed method was 0.7 μg/L, and the limit of quantitation was 2.3 μg/L. Moreover, the imprinted polymer could keep high adsorption capacity for cyromazine after being reused six times at least. Finally, the synthesized graphene oxide molecularly imprinted polymer was successfully used as a satisfied sorbent for high selectivity separation and detection of cyromazine from seawater coupled with high‐performance liquid chromatography.  相似文献   

18.
The dummy molecularly imprinted polymers were prepared by Pickering emulsion polymerization. 4,4′‐(1‐Phenylethylidene) bisphenol was selected as the dummy template to avoid the leakage of the target bisphenols. The microsphere particles were characterized by scanning electron microscopy and nitrogen adsorption–desorption measurements, demonstrating that the regular‐shaped and medium‐sized particles (40–70 μm) were obtained with a specific surface area of 355.759 m2/g and a total pore volume of 0.561 cm3/g. The molecular imprinting properties of the particles were evaluated by static adsorption and chromatographic evaluation experiments. The association constant and maximum adsorption amount of bisphenol A were 0.115 mmol/L and 3.327 μmol/g using Scatchard analysis. The microsphere particles were then used as a solid‐phase extraction sorbent for selective extraction of seven bisphenols. The method of dummy molecularly imprinted solid‐phase extraction coupled with high‐performance liquid chromatography and diode array detection was successfully established for the extraction and determination of seven bisphenols from environmental sediment samples with method detection limits of 0.6–1.1 ng/g. Good recoveries (75.5–105.2%) for sediment samples at two spiking levels (500 and 250 ng/g) and reproducibility (RSDs < 7.7%, n = 3) were obtained.  相似文献   

19.
Xiaoyi Wei  Gengliang Yang  Li Qi 《Talanta》2009,77(3):1197-1807
An on-line solid-phase extraction (SPE)-HPLC method was developed for simultaneous screening of nicardipine and amlodipine in human plasma. A short monolithic poly(glycidyl methacrylate-co-ethylene glycol dimethacrylate) [p(GMA-EDMA)]-based weak cation-exchange (WCX) column was prepared and employed as the selective extraction sorbent, which exhibited good permeability and biocompatibility. During the on-line SPE protocol, high-abundance proteins (human serum albumin, immunoglobulin G, immunoglobulin A and transferrin) and most matrixes in plasma were fast removed while nicardipine and amlodipine were effectively trapped on this monolithic column. Furthermore, the monolithic WCX sorbent could be continuously reused more than 300 times without obvious changes in analytes extraction and proteins cleanup. The proposed method was linear over a range of 0.5-50.0 ng mL−1 for both analytes with a linear regression coefficient greater than 0.998, and the limit of detection (LOD) for each analyte was 0.2 ng mL−1. Validation assays also demonstrated acceptable precision and adequate recovery for simultaneous quantitative screening of nicardipine and amlodipine in human plasma. Real plasma samples from hypertensive patients receiving a dosing of 5 mg antagonists were examined by using the proposed method. Results indicated that the on-line SPE-HPLC method could be applied for simultaneously monitoring of nicardipine and amlodipine in clinical plasma samples.  相似文献   

20.
Bulk and precipitation polymerization methods were used to prepare ibuprofen-molecularly imprinted polymers. Molecularly imprinted polymer-bulk and -precipitation were synthesized in acetonitrile, likewise molecularly imprinted polymer-bulk (mixture) and molecularly imprinted polymer-precipitation (mixture) in a mixture of acetonitrile/toluene (75:25 v/v). N2 adsorption-desorption analysis data revealed that molecularly imprinted polymer-precipitation (mixture) has the highest specific surface area (200.74 m2/g). The surface chemistry and morphology of the synthesized sorbents were investigated by Fourier-transform infrared analysis and scanning electron microscope micrographs respectively. The prepared sorbents in the mixture of solvents were used in a dispersive solid-phase extraction process for selective extraction and pre-concentration of ibuprofen from urine and human plasma samples. The detection limits were 62.91 and 7.89 ng/ml using molecularly imprinted polymer-bulk (mixture) and molecularly imprinted polymer-precipitation (mixture), respectively. Also, the sorbents showed selective behavior to extract ibuprofen in the presence of naproxen, fenoprofen, and ketoprofen. Overall, the results showed that the precipitation method in the mixture of acetonitrile/toluene resulted in the preparation of a sorbent with the highest extraction efficiency. Furthermore, a pharmacokinetic study was done. The maximum plasma concentration, the time required for maximum plasma concentration, and plasma half-life were 28.95 μg/ml, 2, and 2.39 h, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号