首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We present a study on the application of magnetic nanoparticles (MNPs) prepared from Fe3O4 and functionalized with pyridine as an adsorbent for the solid-phase extraction of trace quantities of Pd(II) ion. The pyridine group was immobilized on the surface of the MNPs by covalent bonding of isonicotinamide. The modified MNPs can be readily separated from an aqueous solution by applying an external magnetic field. Effects of pH, the amount of functionalized MNPs, extraction time, type and quantity of eluent, desorption time, break-through volume and interfering ions on the extraction efficiency were optimized. The amount of Pd(II) was then determined using FAAS. Under the optimized conditions, the detection limit and preconcentration factor are 0.15?μg?L-1 and 196, respectively, and the relative standard deviation (at 20?μgL?1; for n?=?10) is 3.7?%. The method had a linear analytical range from 1 to 80?μg?L-1 and was applied to determine Pd(II) in spiked tape water and soil.
Figure
?  相似文献   

2.
We have developed a method for the determination of mercury in water samples that combines dispersive liquid-liquid microextraction (DLLME) with back-extraction (BE) and detection by capillary zone electrophoresis. DLLME is found to be a simple, cost-effective and rapid method for extraction and preconcentration. The BE procedure is based on the fact that the stability constant of the hydrophilic chelate of Hg(II) with L-cysteine is much larger than that of the respective complex with 1-(2-pyridylazo)-2-naphthol. Factors affecting complex formation and extraction efficiency (such as pH value, concentration of the chelating agent, time of ultrasonication and extraction, and type and quantity of disperser solvent) were optimized. Under the optimal conditions, the enrichment factor is 625, and the limit of detection is 0.62???g?L?1. The calibration plot is linear in the range between 1 and 1,000???g?L?1 (R 2?=?0.9991), and the relative standard deviation (RSD, for n?=?6) is 4.1%. Recoveries were determined with tap water and seawater spiked at levels of 10 and 100???g?L?1, respectively, and ranged from 86.6% to 95.1%, with corresponding RSDs of 3.95?C5.90%.
Figure
A method was developed based on the combination of dispersive liquid-liquid microextraction with back-extraction showing simplicity, cost-effectiveness, and rapidity for remarkably enhanced preconcentration, and detection by capillary zone electrophoresis occupying high resolving power, rapidity, low-cost, and environmental benignity, and applied for highly selective determination of trace mercury in water samples.  相似文献   

3.
We have developed a technique for the solid-phase extraction of gold using various kinds of pyridine-functionalized nanoporous silica prior to its determination in various samples using FAAS. The effects of solution pH, sample and eluent flow rate, sample volume and of potentially interfering ions are compared. The limits of detections vary from 28 to 53?pg?mL?1. The accuracy and precision are between 99.8% and 98.3?% and 0.7 to 1.6?% (RSD), respectively. The method was successfully applied to several standard reference materials.
Figure
A technique has been developed for the solid-phase extraction of gold using various kinds of pyridine-functionalized nanoporous silica prior to its determination in various samples using FAAS.  相似文献   

4.
We report on a simple, rapid, and efficient method for the extraction of volatile organic compounds (VOCs; including methanol, tetrahydrofuran, 2-hexanone and benzene) from air and solid samples. The system is based on the use of a laboratory-made syringe as the extractor. The needle of the syringe is placed in a chamber cooled by liquid nitrogen. The tip of the needle is placed in the headspace of a vial containing the sample. The headspace components then are circulated with a pump to pass the needle, and this results in freeze-trapping of the VOCs on the inner surface of the needle. The circulation of the headspace components is continued for 15 min, and the syringe is then removed and placed in a GC injector. The effects of volume of the sample vial, headspace flow rate, temperature and time of extraction and desorption were optimized. The overall time for sampling and analysis is <30 min. The method displays an extraction efficiency of >80%) and a good sample transfer efficiency into the GC column due to the absence of a sorbent inside the needle. No carry-over was observed after 30?s desorption at 260?°C. An external standard method was used for quantitative analysis. The relative standard deviation values are below 10% and the limits of detection range from 1.3 to 4.6?ng?g?1.
Fiugre
The scheme of sorbentless cryogenic needle trap device  相似文献   

5.
We report on a new method for the selective extraction of the antibiotic sulfamethoxazole (SMO) in milk that is making use of a molecularly imprinted polymer (MIP) monolith as the sorbent. The monolith was synthesized in the tip of a micropipette using SMO as the template and a combination of acrylamide and 4-vinylpyridine as the co-functional monomers. The monolith was connected to syringes in different sizes and used for microextraction without any other treatment and showed high selectivity and enrichment ability for SMO. It was applied to the selective extraction and sensitive determination of SMO in milk. The linear range is from 5–600?μg?L?1, the correlation coefficient (r2) is 0.9984, and the detection limit (at S/N?=?3) is 1?μg?L?1. Recoveries range from 93.6 to 101.7?%, with relative standard deviations of <6.1?%.
Figure
A method for the selective extraction of sulfamethoxazole (SMO) in milk based on molecularly imprinted polymer (MIP) monolith as the sorbent was developed. The linear ranges were 5–600?μg/L for SMO in milk. High recoveries of 93.6?~?101.7?% from milk were obtained with relative standard deviations less than 6.1?%.  相似文献   

6.
We report on the determination of bisphenol A and 2-naphthol in water samples using ionic liquid cold-induced aggregation dispersive liquid-liquid microextraction combined with HPLC. Parameters governing the extraction efficiency (disperser solvent, volume of extraction and disperser solvent, pH, temperature, extraction time) were optimized and resulted in enrichment factors of 112 for bisphenol A and of 186 for 2-naphthol. The calibration curve was linear with correlation coefficients of 0.9995 and 0.9998, respectively, in the concentration range from 1.5 to 200?ng?mL?1. The relative standard deviations are 2.3% and 4.1% (for n?=?5), the limits of detection are 0.58 and 0.86?ng?mL?1, and relative recoveries in tap, lake and river water samples range between 100.1 and 108.1%, 99.4 and 106.2%, and 97.1 and 103.8%, respectively.
Figure
IL-CIA-DLLME has a high enrichment factor (112, 186), acceptable relative recovery (97.1%?C108.1%), good repeatability (2.3%, 4.1%) and a wide linear range(1.5?C200?ng?mL?1 ) for the determination of bisphenol A and 2-naphthol.  相似文献   

7.
We have developed a rapid, selective and efficient method for dispersive solid-phase microextraction (DSPME) using microbeads of a molecularly imprinted polymer (MIP). It enables the pre-concentration of sulfamethazine and sample clean-up prior to capillary electrophoresis with UV detection. The microbeads were synthesized via precipitation polymerization using sulfamethazine, methacrylic acid and ethylene glycol dimethacrylate (EGDMA) as the template molecule, the functional monomer and the cross-linking monomer, respectively. Characterization by SEM displayed the high uniformity and dispersibility of the MIP microbeads. The adsorption and desorption of sulfamethazine and the parameters for CE were optimized to result in a limit of detection of 1.1?μg?L?1, which is 373-fold lower than that of direct CE detection. The equilibration time of extraction was reduced to 5?min, and the selectivity of the microbeads was significantly improved compared to the non-imprinted polymer. The method was successfully applied to the determination of trace sulfamethazine in several milk samples, with recoveries in the range of 89?% to 110?%.
Figure
A novel, rapid, selective and efficient dispersive solid-phase microextraction approach using molecularly imprinted polymer microbeads was developed for pre-concentration of sulfamethazine and sample clean-up prior to capillary electrophoresis detection.  相似文献   

8.
For the first time, an electromembrane extraction combined with a HPLC procedure using diode array and fluorescence detection has been developed for the determination of seven widely used fluoroquinolones (FQs): marbofloxacin, norfloxacin, ciprofloxacin, danofloxacin, enrofloxacin, gatifloxacin and grepafloxacin. The drugs were extracted from acid aqueous sample solutions (pH 5), through a supported liquid membrane consisting of 1-octanol impregnated in the walls of a S6/2 Accurel® polypropylene hollow fiber, to an acid (pH 2) aqueous acceptor solution inside the lumen of the hollow fiber. The main operational parameters were optimized, and extractions were carried out in 15 min using a potential of 50 V. Enrichment factors of 40–85 have been obtained using only 15 min of extraction time versus 330 min used in a previously proposed hollow-fiber liquid-phase microextraction procedure. The procedure allows low detection and quantitation limits of 0.005–0.07 and 0.007–0.15 μg?L?1, respectively. The proposed method was successfully applied to the FQs analysis in urban wastewaters.
Figure
EME for HPLC determination of fluoroquinolones in wastewater  相似文献   

9.
We report on a new method for sample pretreatment. It is based on solid-phase extraction combined with dispersive liquid-liquid microextraction (SPE-DLLME) and was applied to the determination of carbamates in apple and cucumber. The carbamates carbofuran, carbaryl, and pirimicarb were first extracted from samples by SPE. The analytes were then eluted from the sorbent with acetonitrile, and the DLLME technique was then applied to the resulting eluate. Finally, the analytes in the extraction solvent were determined by HPLC. Several parameters affecting the SPE-DLLME process were optimized. The new method provides enrichment factors that range from 5,400 to 7,650. Calibration plots are linear in the range from 0.25 to 100?μg?kg?1 for carbofuran and carbaryl, and from 0.10 to 100?μg?kg?1 for pirimicarb, with correlation coefficient (r2) ranging from 0.9980 to 0.9997. The limits of detection range from 5 to 60?pg?kg?1 (at S/N?=?3). The method was successfully applied to the extraction and sensitive determination of carbamates in apple and cucumber samples.
Graphical abstract
Chromatograms of non-spiked apple sample with the treatment of SPE-DLLME (1), apple sample spiked with carbamates at the concentration of 10.0 μg kg-1 without (2) / with (3) the treatment of SPE-DLLME.  相似文献   

10.
We have developed a highly sensitive microextraction method for the preconcentration of some phthalate esters such as diethyl phthalate, di-n-propylphthalate, di-n-butyl-phthalate, dicyclohexyl-phthalate, and diethyl-hexyl phthalate prior to their determination by HPLC. It is based on a magnetic graphene nanocomposite as an effective adsorbent. The effects of the amount of the extractant composite employed, extraction time, pH values, salt concentration and desorption conditions were investigated. Under the optimum conditions, the enrichment factors range from 1574 to 2880. Response is linear in the concentration range from 0.1 to 50?ng?mL?1. The limits of detection (at S/N?=?3) were between 0.01 and 0.04?ng?mL?1. The method was successfully applied to the determination of five phthalate esters in water and beverage samples.
A novel microextraction method was developed by using magnetic graphene nanocomposite as an effective adsorbent for the preconcentration of some trace phthalate esters in water and beverage samples followed by high performance liquid chromatography with ultraviolet detection. The enrichment factors of the method for the compouds were achieved ranging from 1574 to 2880.  相似文献   

11.
We have developed a method, termed solidification of floating organic drop microextraction (SFOME), for the extraction of polybrominated diphenyl ethers (PBDEs) in water and urine samples, this followed by quantification via HPLC. This method requires very small quantities of organic solvent consumption. It is based on exposing a floating solidified drop of an organic solvent on the surface of aqueous solution in a sealed vial. The organic drop is easily collected with a spatula, molten (at ambient temperature), and then submitted to HPLC. Experimental parameters including extraction solvent and its volume, disperser solvent and its volume, extraction time, ionic strength, stirring speed and extraction temperature were optimized. The enrichment factors of analytes are in the range from 921 to 1,462, and acceptable extraction recoveries (92%–118%) are obtained. The dynamic linear range for five PBDE congeners is in the range of 0.5–75?μg.L?1 and from 5 to 500?μg.L?1 for BDE 209. The correlation coefficients range from 0.9960 to 0.9999. The limits of detection (at S/N?=?3) for PBDE congeners vary between 0.01 and 0.04?μg.L?1. This method has been successfully applied to detecting PBDEs in two environmental waters and in human urine.
Figure
Under optimized conditions, the enrichment factors of PBDEs by solidification of floating organic drop microextraction were from 921 to 1,462, and extraction recoveries (92%–118%) were obtained. The correlation coefficients ranged from 0.9960 to 0.9999. The limits of detection (at S/N?=?3) for PBDE congeners varied between 0.01 and 0.04?μg.L?1.  相似文献   

12.
We have prepared a novel caffeine imprinted polymer on a stir bar that can be used for selective extraction of caffeine, theobromine and theophylline from beverages. The polymerization time and quantities of reagents (template, cross-linker, porogenic solvent) were optimized. The morphology of the molecularly imprinted polymer-coating was studied by scanning electron microscopy and Fourier transform IR spectroscopy. A rapid and sensitive method was worked out for the extraction of caffeine, theobromine and theophylline from beverages by using the molecularly imprinted stir bar followed by HPLC analysis. The effects of extraction solvent, stirring speed, desorption solvent, adsorption and desorption time were optimized. The method displays a linear response in the 5–150 μg L?1 caffein concentration range, with a correlation coefficient of >0.9904. The recoveries for three analytes in tea, carbonated and functional beverages were 91–108 %, 90–110 % and 93–109 %, with relative standard deviations ranging from 3.6–5.7 %, 3.5–7.9 % and 3.2–7.9 %, respectively.
Figure
A molecularly imprinted stir bar was prepared and applied for the selective extraction and sensitive determination of caffeine and its analogues in beverages by coupling with HPLC. The limits of detection were in the range of 1.24–2.25 μg L?1 (S/N?=?3) which are lower than those in published papers  相似文献   

13.
We report on a method for the extraction of the lanthanide ions La(III), Sm(III), Nd(III) and Pr(III) using a carbon-ferrite magnetic nanocomposite as a new adsorbent, and their determination via flow injection ICP-OES. The lanthanide ions were converted into their complexes with 4-(2-pyridylazo)resorcinol, and these were adsorbed onto the nanocomposite. Fractional factorial design and central composite design were applied to optimize the extraction efficiencies to result in preconcentration factors in the range of 141–246. Linear calibration plots were obtained, the limits of detection (at S/N?=?3) are between 0.5 and 10 μg?L?1, and the intra-day precisions (n?=?3) range from 3.1 to 12.8 %. The method was successfully applied to a certified reference material.
Figure
Superparamagnetic activated carbon based nanocomposite was synthesized and applied for extraction and determination of some rare earth elements in water samples  相似文献   

14.
We have developed a fast method for sensitive extraction and determination of the metal ions silver(I), gold(III), copper(II) and palladium(II). Fe3O4 magnetic nanoparticles were modified with polythiophene and used for extraction the metal ions without a chelating agent. Following extraction, the ions were determined by flow injection inductively coupled plasma optical emission spectrometry. The influence of sample pH, type and volume of eluent, amount of adsorbent, sample volume and time of adsorption and desorption were optimized. Under the optimum conditions, the calibration plots are linear in the 0.75 to 100 μg L?1 concentration range (R2?>?0.998), limits of detection in the range from 0.2 to 2.0 μg L?1, and enhancement factors in the range from 70 to 129. Precisions, expressed as relative standard deviations, are lower than 4.2 %. The applicability of the method was demonstrated by the successful analysis of tap water, mineral water, and river water.
Figure
In the present work, polythiophene-coated Fe3O4 nanoparticles have been successfully synthesized and were applied as adsorbent for magnetic solid-phase extraction of some precious metal ions.  相似文献   

15.
The effect of thiol compounds on the kinetics of the aggregation of gold nanoparticles in the presence of the cationic surfactant cetyltrimethyl ammonium bromide has been studied. It was applied to the determination of N-acetylcysteine using the stopped-flow mixing technique along with light scattering detection. The signal obtained was measured after about 5?s, and gave the analytical information for a calibration graph in the concentration range from 2.9 to 60???mol?L?1 of N-acetylcysteine, and a detection limit of 0.87???mol?L?1. The effect of other thiols on the system is also described. The relative standard deviation ranges between 0.6% and 3.5%. The method was applied to the determination of N-acetylcysteine in several pharmaceutical samples with recoveries that range from 97.7% to 101.1%.
Figure
S1, S2: stopped-flow driving syringes  相似文献   

16.
We are introducing a method for the determination of some polycyclic aromatic hydrocarbons in aqueous saffron sample by direct immersion solid phase microextraction (SPME) and gas chromatography. A sol–gel technique is used for the preparation of the SPME fibers. Three kinds of sol–gel coatings on the fibers were tested and compared. They are composed of poly(dimethyl siloxane) (PDMS), poly(ethylene glycol) (PEG), and a poly(ethylene glycol) modified with multi-walled carbon nanotubes (PEG/CNTs). The effects of fiber coating, desorption time, desorption temperature, extraction time, stirring speed and salting effect were optimized. Under the optimal conditions, the detection limits (at S/N?=?3) are 7–50, 5–50, and 1–10?pg?mL–1, respectively, for SPME fibers made from PDMS, PEG and PEG/CNTs. The relative standard deviations for one type of fiber are from 2.1% to 9.6% for all fibers (at n?=?5), and in the range from 1.9% to 9.8% from batch to batch (for n?=?3).
Figure
SPME based on sol–gel technology was proposed for determination of in extraction of naphthalene, fluorene, anthracene and phenanthrene from saffron samples extractants. Three different SPME fibers, i.e. PDMS, PEG and PEG/CNT, based on sol–gel were made. A comparative study of the coating fibers was done. This method has wide dynamic range and high sensitivity.  相似文献   

17.
A sensitive and accurate method was developed and validated for simultaneous analysis of perfluoroalkyl carboxylic acids, sulfonic acids, and phosphonic acids (PFPAs) at low picograms per gram concentrations in a variety of food matrices. The method employed extraction with acetonitrile/water and cleanup on a mixed-mode co-polymeric sorbent (C8?+?quaternary amine) using solid-phase extraction. High-performance liquid chromatographic separation was achieved on a C18 column using a mobile phase gradient containing 5?mM 1-methyl piperidine for optimal chromatographic resolution of PFPAs. A quadrupole time-of-flight high-resolution mass spectrometer operating in negative ion mode was used as detector. Method detection limits were in the range of 0.002 to 0.02?ng?g?1 for all analytes. Sample preparation (extraction and cleanup) recoveries at a spiking level of 0.1?ng?g?1 to a baby food composite were in the range of 59 to 98?%. A strong matrix effect was observed in the analysis of PFPAs in food extracts, which was tentatively assigned to sorption of PFPAs to the injection vial in the solvent-based calibration standard. The method was successfully applied to a range of different food matrices including duplicate diet samples, vegetables, meat, and fish samples.
Figure
Extracted high-resolution mass chromatograms of a PFPAs spiked at 0.06 ng g?–1 to baby food, b PFSAs spiked at 0.02 ng g?–1 to baby food, and c PFCAs spiked at 0.02 ng g?–1 to baby food  相似文献   

18.
We have immobilized iminodiacetic acid on mesoporous Fe3O4@SiO2 microspheres and used this material for efficient and cost effective method of magnetic solid phase extraction (SPE) of trace levels of Cd, Mn and Pb. The microspheres were characterized by infrared spectroscopy, scanning electron microscopy and transmission electron microscopy. The loaded microspheres can be easily separated from the aqueous sample solution by applying an external magnetic field. The effects of pH, sample volume, concentration and volume of eluent, and of interfering ions were investigated in detail. The method has detection limit of 0.16, 0.26 and 0.26?ng?L?1 for the ions of Cd, Mn and Pb, respectively, and the relative standard deviations (RSDs, c?=?1???g?L?1, n?=?7) are 4.8%, 4.6% and 7.4%. The method was successfully applied to the determination of these metals in biological and environmental samples using ICP-MS. Two certified reference materials were analyzed, and the results coincided well with the certified values.
Figure
Mesoporous Fe3O4@SiO2@IDA magnetic particles for fast and selective magnetic solid phase extraction of trace Cd, Mn and Pb from environmental and biological samples followed by inductively coupled plasma mass spectrometry detection.  相似文献   

19.
We have developed a simple method for the extraction of sulfonylurea herbicides (SUHs) from environmental water samples. It is based on a magnetic molecular imprint (MMIP) as a sorbent. The MMIP was prepared using metsulfuron-methyl as the template molecule, methacrylic acid as the functional monomer, trimethylolpropane trimethacrylate as the cross-linking agent, and magnetite as the magnetic component. Extraction can be carried out by blending and stirring water sample, extraction solvent and MMIP. Once the extraction is completed, the MMIP containing the SUHs can be separated from the sample matrix with a magnet. The SUHs desorbed from the polymers were then quantified by capillary liquid chromatography with diode array detection. The limits of quantification are in the range of 0.08 to 0.1 ng?mL?1. Repeatabilities of peak areas and retention times range from 2.9 % to 4.0 % and from 0.1 % to 0.3 %, respectively. The method was successfully applied to the determination of the SUHs bensulfuron-methyl, metsulfuronmethyl, pyrazosulfuron-methyl, thifensulfuron-methyl, and triasulfuron in waste water samples. Recoveries range from 94.3 % to 102.3 %.
Figure
Scheme of sulfonylurea herbicide preconcentration  相似文献   

20.
We report on the synthesis of Fe3O4-functionalized metal-organic framework (m-MOF) composite from Zn(II) and 2-aminoterephthalic acid by a hydrothermal reaction. The magnetic composite is iso-reticular and was characterized by FTIR, X-ray diffraction, SEM, magnetization, and TGA. The m-MOF was then applied as a sorbent for the solid-phase extraction of trace levels of copper ions with subsequent quantification by electrothermal AAS. The amount of sorbent applied, the pH of the sample solution, extraction time, eluent concentration and volume, and desorption time were optimized. Under the optimum conditions, the enrichment factor is 50, and the sorption capacity of the material is 2.4 mg g?1. The calibration plot is linear over the 0.1 to 10 μg L?1 Cu(II) concentration range, the relative standard deviation is 0.4 % at a level of 0.1 μg L?1 (for n?=?10), and the detection limit is as low as 73 ng L?1. We consider this magnetic MOF composite to be a promising and highly efficient material for the preconcentration of metal ions.
Figure
Magnetic metal-organic frameworks was synthesized and used as a new sorbent for lead adsorption with detection by electrothermal atomic absorption spectrometry.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号