首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A fully integrated microdevice and process for forensic short tandem repeat (STR) analysis has been developed that includes sequence-specific DNA template purification, polymerase chain reaction (PCR), post-PCR cleanup and inline injection, and capillary electrophoresis (CE). Fragmented genomic DNA is hybridized with biotin-labeled capture oligos and pumped through a fluidized bed of magnetically immobilized streptavidin-coated beads in microchannels where the target DNA is bound to the beads. The bead-DNA conjugates are then transferred into a 250 nL PCR reactor for autosomal STR amplification using one biotin and one fluorescence-labeled primer. The resulting biotin-labeled PCR products are electrophoretically injected through a streptavidin-modified capture gel where they are captured to form a concentrated and purified injection plug. The thermally released sample plug is injected into a 14 cm long CE column for fragment separation and detection. The DNA template capture efficiency provided by the on-chip sequence-specific template purification is determined to be 5.4% using K562 standard DNA. This system can produce full 9-plex STR profiles from 2.5 ng input standard DNA and obtain STR profiles from oral swabs in about 3 hours. This fully integrated microsystem with sample-in-answer-out capability is a significant advance in the development of rapid, sensitive, and reliable micro-total analysis systems for on-site human identification.  相似文献   

2.
Despite the controversies surrounding genetically modified organisms (GMOs), the production of GM crops is increasing, especially in developing countries. Thanks to new technologies involving genetic engineering and unprecedented access to genomic resources, the next decade will certainly see exponential growth in GMO production. Indeed, EU regulations based on the precautionary principle require any food containing more than 0.9% GM content to be labeled as such. The implementation of these regulations necessitates sampling protocols, the availability of certified reference materials and analytical methodologies that allow the accurate determination of the content of GMOs. In order to qualify for the validation process, a method should fulfil some criteria, defined as “acceptance criteria” by the European Network of GMO Laboratories (ENGL). Several methods have recently been developed for GMO detection and quantitation, mostly based on polymerase chain reaction (PCR) technology. PCR (including its different formats, e.g., double competitive PCR and real-time PCR) remains the technique of choice, thanks to its ability to detect even small amounts of transgenes in raw materials and processed foods. Other approaches relying on DNA detection are based on quartz crystal microbalance piezoelectric biosensors, dry reagent dipstick-type sensors and surface plasmon resonance sensors. The application of visible/near-infrared (vis/NIR) spectroscopy or mass spectrometry combined with chemometrics techniques has also been envisaged as a powerful GMO detection tool. Furthermore, in order to cope with the multiplicity of GMOs released onto the market, the new challenge is the development of routine detection systems for the simultaneous detection of numerous GMOs, including unknown GMOs.  相似文献   

3.
For years, an increasing number and diversity of genetically modified plants has been grown on a commercial scale. The need for detection and identification of these genetically modified organisms (GMOs) calls for broad and at the same time flexible high throughput testing methods. Here we describe the development and validation of a hexaplex real-time polymerase chain reaction (PCR) screening assay covering more than 100 approved GMOs containing at least one of the GMO targets of the assay. The assay comprises detection systems for Cauliflower Mosaic Virus 35S promoter, Agrobacterium tumefaciens NOS terminator, Figwort Mosaic Virus 34S promoter and two construct-specific sequences present in novel genetically modified soybean and maize that lack common screening elements. Additionally a detection system for an internal positive control (IPC) indicating the presence or absence of PCR inhibiting substances was included. The six real-time PCR systems were allocated to five detection channels showing no significant crosstalk between the detection channels. As part of an extensive validation, a limit of detection (LODabs) ≤ ten target copies was proven in hexaplex format. A sensitivity ≤ ten target copies of each GMO detection system was still shown in highly asymmetric target situations in the presence of 1,000 copies of all other GMO targets of each detection channel. Furthermore, the applicability to a broad sample spectrum and reliable indication of inhibition by the IPC system was demonstrated. The presented hexaplex assay offers sensitive and reliable detection of GMOs in processed and unprocessed food, feed and seed samples with high efficiency.  相似文献   

4.
In 2003 the European Commission introduced a 0.9 % threshold for food and feed products containing genetically modified organism (GMO)-derived components. For commodities containing GMO contents higher than this threshold, labelling is mandatory. To provide a DNA-based rapid and simple detection method suitable for high-throughput screening of GMOs, several isothermal amplification approaches for the 35S promoter were tested: strand displacement amplification, nicking-enzyme amplification reaction, rolling circle amplification, loop-mediated isothermal amplification (LAMP) and helicase-dependent amplification (HDA). The assays developed were tested for specificity in order to distinguish between samples containing genetically modified (GM) maize and non-GM maize. For those assays capable of this discrimination, tests were performed to determine the lower limit of detection. A false-negative rate was determined to rule out whether GMO-positive samples were incorrectly classified as GMO-negative. A robustness test was performed to show reliable detection independent from the instrument used for amplification. The analysis of three GM maize lines showed that only LAMP and HDA were able to differentiate between the GMOs MON810, NK603, and Bt11 and non-GM maize. Furthermore, with the HDA assay it was possible to realize a detection limit as low as 0.5 %. A false-negative rate of only 5 % for 1 % GM maize for all three maize lines shows that HDA has the potential to be used as an alternative strategy for the detection of transgenic maize. All results obtained with the LAMP and HDA assays were compared with the results obtained with a previously reported real-time PCR assay for the 35S promoter in transgenic maize. This study presents two new screening assays for detection of the 35S promoter in transgenic maize by applying the isothermal amplification approaches HDA and LAMP.  相似文献   

5.
6.
The use of genetically modified organisms (GMOs) as food and in food products is becoming more and more widespread. Polymerase chain reaction (PCR) technology is extensively used for the detection of GMOs in food products in order to verify compliance with labeling requirements. In this paper, we present a novel close-loop ferrofluid-driven PCR microchip for rapid amplification of GMOs. The microchip was fabricated in polymethyl methacrylate by CO2 laser ablation and was integrated with three temperature zones. PCR solution was contained in a circular closed microchannel and was driven by magnetic force generated by an external magnet through a small oil-based ferrofluid plug. Successful amplification of genetically modified soya and maize were achieved in less than 13 min. This PCR microchip combines advantages of cycling flexibility and quick temperature transitions associated with two existing microchip PCR techniques, and it provides a cost saving and less time-consuming way to conduct preliminary screening of GMOs. Figure Schematic of the circular ferrofluid-driven PCR microchip  相似文献   

7.
Eshleman J  Smith DG 《Electrophoresis》2001,22(20):4316-4319
Using polymerase chain reaction (PCR) amplification, it is possible to analyze DNA from limited source template. This method has proved especially valuable in studies of ancient DNA and in forensic investigations. However, PCR reactions containing minimal or damaged source template are prone to contamination by DNA from a number of other sources. While standard protocols to prevent and/or detect contamination do exist, methods of eliminating contamination are needed to ensure the validity of results obtained. We present a method to eliminate sources of contamination in reagents and labware through the use of a DNase prior to PCR amplification without damaging even the minimal amounts of template present in ancient DNA samples. This method, suggested previously for forensics applications, appears to be effective in eliminating contamination without interfering with the amplification of ancient template.  相似文献   

8.
A novel real-time PCR microchip platform with integrated thermal system and polymer waveguides has been developed. The integrated polymer optical system for real-time monitoring of PCR was fabricated in the same SU-8 layer as the PCR chamber, without additional masking steps. Two suitable DNA binding dyes, SYTOX Orange and TO-PRO-3, were selected and tested for the real-time PCR processes. As a model, cadF gene of Campylobacter jejuni has been amplified on the microchip. Using the integrated optical system of the real-time PCR microchip, the measured cycle threshold values of the real-time PCR performed with a dilution series of C. jejuni DNA template (2 to 200 pg/microL) could be quantitatively detected and compared with a conventional post-PCR analysis (DNA gel electrophoresis). The presented approach provided reliable real-time quantitative information of the PCR amplification of the targeted gene. With the integrated optical system, the reaction dynamics at any location inside the micro reaction chamber can easily be monitored.  相似文献   

9.
Progress in genetic engineering has led to the introduction of genetically modified organisms (GMOs) whose genomes have been altered by the integration of a novel sequence conferring a new trait. To allow consumers an informed choice, many countries require food products to be labeled if the GMO content exceeds a certain threshold. Consequently, the development of analytical methods for GMO screening and quantification is of great interest. Exponential amplification by the polymerase chain reaction (PCR) remains a central step in molecular methods of GMO detection and quantification. In order to meet the challenge posed by the continuously increasing number of GMOs, various multiplex assays have been developed for the simultaneous amplification and/or detection of several GMOs. Classical agarose gel electrophoresis is being replaced by capillary electrophoresis (CE) systems, including CE chips, for the rapid and automatable separation of amplified fragments. Microtiter well-based hybridization assays allow high-throughput analysis of many samples in a single plate. Microarrays have been introduced in GMO screening as a technique for the simultaneous multianalyte detection of amplified sequences. Various types of biosensors, including surface plasmon resonance sensors, quartz crystal microbalance piezoelectric sensors, thin-film optical sensors, dry-reagent dipstick-type sensors and electrochemical sensors were introduced in GMO screening because they offer simplicity and lower cost. GMO quantification is performed by real-time PCR (rt-QPCR) and competitive PCR. New endogenous reference genes have been validated. rt-QPCR is the most widely used approach. Multiplexing is another trend in this field. Strategies for high-throughput multiplex competitive quantitative PCR have been reported.  相似文献   

10.
PCR is an indispensable technique used in DNA analysis. However, with the traditional methods, the time spent on amplification and the subsequent analysis of PCR products is generally long. Therefore, it is essential to improve these two steps so that the whole procedure can be made faster. In the present work, with lambda-DNA as the control template, the amplification of 300-bp fragment could be completed within 37 s with capillary reaction chambers of LightCycler, and the following analysis of PCR products could be completed within 120 s with microchip electrophoresis as the detector. Since the high detection sensitivity of microchip electrophoresis, PCR products with template concentration as low as 5 fg/microL could be detected only after 435 s of amplification. In addition, based on additional optimized conditions simulated by CoventorWare, PCR microchips with distinct structure of the reaction chambers have been designed and successfully applied to the amplification of 300-bp fragment. By comparison, those chambers with ellipse and racket shapes were found to offer very high amplification efficiency. All of these results demonstrate the promise of integrating PCR and electrophoresis on microchip for developing easy-carrying instruments for the fast in situ detection of DNA.  相似文献   

11.
The number of commercially available genetically modified organisms (GMOs) and therefore the diversity of possible target sequences for molecular detection techniques are constantly increasing. As a result, GMO laboratories and the food production industry currently are forced to apply many different methods to reliably test raw material and complex processed food products. Screening methods have become more and more relevant to minimize the analytical effort and to make a preselection for further analysis (e.g., specific identification or quantification of the GMO). A multiplex real-time PCR kit was developed to detect the 35S promoter of the cauliflower mosaic virus, the terminator of the nopaline synthase gene of Agrobacterium tumefaciens, the 35S promoter from the figwort mosaic virus, and the bar gene of the soil bacterium Streptomyces hygroscopicus as the most widely used sequences in GMOs. The kit contains a second assay for the detection of plant-derived DNA to control the quality of the often processed and refined sample material. Additionally, the plant-specific assay comprises a homologous internal amplification control for inhibition control. The determined limits of detection for the five assays were 10 target copies/reaction. No amplification products were observed with DNAs of 26 bacterial species, 25 yeasts, 13 molds, and 41 not genetically modified plants. The specificity of the assays was further demonstrated to be 100% by the specific amplification of DNA derived from reference material from 22 genetically modified crops. The applicability of the kit in routine laboratory use was verified by testing of 50 spiked and unspiked food products. The herein described kit represents a simple and sensitive GMO screening method for the reliable detection of multiple GMO-specific target sequences in a multiplex real-time PCR reaction.  相似文献   

12.
Current screening and event-specific polymerase chain reaction (PCR) assays for the detection and identification of genetically modified organisms (GMOs) in samples of unknown composition or for the detection of non-regulated GMOs have limitations, and alternative approaches are required. A transgenic DNA fingerprinting methodology using restriction enzyme digestion, adaptor ligation, and nested PCR was developed where individual GMOs are distinguished by the characteristic fingerprint pattern of the fragments generated. The inter-laboratory reproducibility of the amplified fragment sizes using different capillary electrophoresis platforms was compared, and reproducible patterns were obtained with an average difference in fragment size of 2.4 bp. DNA insert fingerprints for 12 different maize events, including two maize hybrids and one soy event, were generated that reflected the composition of the transgenic DNA constructs. Once produced, the fingerprint profiles were added to a database which can be readily exchanged and shared between laboratories. This approach should facilitate the process of GMO identification and characterization.  相似文献   

13.
The amplification of target DNA by the polymerase chain reaction (PCR) produces copies which may contain errors. Two sources of errors are associated with the PCR process: (1) editing errors that occur during DNA polymerase-catalyzed enzymatic copying and (2) errors due to DNA thermal damage. In this study a quantitative model of error frequencies is proposed and the role of reaction conditions is investigated. The errors which are ascribed to the polymerase depend on the efficiency of its editing function as well as the reaction conditions; specifically the temperature and the dNTP pool composition. Thermally induced errors stem mostly from three sources: A+G depurination, oxidative damage of guanine to 8-oxoG and cytosine deamination to uracil. The post-PCR modifications of sequences are primarily due to exposure of nucleic acids to elevated temperatures, especially if the DNA is in a single-stranded form. The proposed quantitative model predicts the accumulation of errors over the course of a PCR cycle. Thermal damage contributes significantly to the total errors; therefore consideration must be given to thermal management of the PCR process.  相似文献   

14.
NAIMA as a solution for future GMO diagnostics challenges   总被引:1,自引:0,他引:1  
In the field of genetically modified organism (GMO) diagnostics, real-time PCR has been the method of choice for target detection and quantification in most laboratories. Despite its numerous advantages, however, the lack of a true multiplexing option may render real-time PCR less practical in the face of future GMO detection challenges such as the multiplicity and increasing complexity of new transgenic events, as well as the repeated occurrence of unauthorized GMOs on the market. In this context, we recently reported the development of a novel multiplex quantitative DNA-based target amplification method, named NASBA implemented microarray analysis (NAIMA), which is suitable for sensitive, specific and quantitative detection of GMOs on a microarray. In this article, the performance of NAIMA is compared with that of real-time PCR, the focus being their performances in view of the upcoming challenge to detect/quantify an increasing number of possible GMOs at a sustainable cost and affordable staff effort. Finally, we present our conclusions concerning the applicability of NAIMA for future use in GMO diagnostics.  相似文献   

15.
We report a novel, high-throughput genotyping method by single nucleotide polymorphism (SNP) analysis using bidirectional allele-specific amplification with polymerase chain reaction (PCR) in a single-step/single-tube format. Blood coagulation factor V G1691A (also referred to as Leiden) mutation was chosen as a model system for SNP detection, as this is one of the most common inherited risk factors of thrombosis, effecting 2-5% of the human population. The rationale of our method is the production of allele-specific PCR fragments, different in size, which was achieved by bidirectional amplification, starting from the position of the mutation. Thus, both homozygosity and heterozygosity were readily identified from a single reaction by simply determining the sizes of the resulting PCR products. The advantage of our assay, compared to other single-tube systems, is that this method did not require the use of pre-PCR labeled (fluorophore) primers or probes. Preferential production of the allele-specific products was achieved by a hot-start, time release PCR system. Specificity was increased by introducing a mismatch in the 3'-antepenultimate position of the allele-specific primers. This method made possible the large-scale screening for the factor V Leiden mutation using single-tube PCR followed by automated ultrathin-layer agarose gel electrophoresis, with real-time detection of the "in migratio" ethidium-bromide-labeled fragments.  相似文献   

16.
A review is presented demonstrating that biospecific interaction analysis, using surface plasmon resonance (SPR) and biosensor technologies is a simple, rapid, and automatable approach to detect genetically modified organisms (GMOs). Using SPR, we were able to monitor in real-time the hybridization between oligonucleotide or polymerase chain reaction (PCR)-generated probes and target single-stranded PCR products obtained by using as substrates DNA isolated from normal or transgenic soybean and maize. This procedure allows a one-step, nonradioactive detection of GMOs. PCR-generated probes are far more efficient in detecting GMOs than are oligodeoxyribonucleotide probes. This is expected to be a very important parameter, because information on low percentage of GMOs is of great value. Determination of the ability of SPR-based analysis to quantify GMOs should be considered a major research field for future studies, especially for the analyses of food supplies.  相似文献   

17.
As part of a standardization project, an interlaboratory trial including 15 laboratories from 13 European countries was conducted to evaluate the performance of a noproprietary polymerase chain reaction (PCR)-based method for the detection of Salmonella on artificially contaminated chicken rinse and pig swab samples. The 3 levels were 1-10, 10-100, and 100-1000 colony-forming units (CFU)/100 mL. Sample preparations, including inoculation and pre-enrichment in buffered peptone water (BPW), were performed centrally in a German laboratory; the pre-PCR sample preparation (by a resin-based method) and PCR assay (gel electrophoresis detection) were performed by the receiving laboratories. Aliquots of BPW enrichment cultures were sent to the participants, who analyzed them using a thermal lysis procedure followed by a validated Salmonella-specific PCR assay. The results were reported as negative or positive. Outlier results caused, for example, by gross departures from the experimental protocol, were omitted from the analysis. For both the chicken rinse and the pig swab samples, the diagnostic sensitivity was 100%, with 100% accordance (repeatability) and concordance (reproducibility). The diagnostic specificity was 80.1% (with 85.7% accordance and 67.5% concordance) for chicken rinse, and 91.7% (with 100% accordance and 83.3% concordance) for pig swab. Thus, the interlaboratory variation due to personnel, reagents, thermal cyclers, etc., did not affect the performance of the method, which will be proposed as part of a developing international PCR standard.  相似文献   

18.
Aptamers are DNA oligonucleotides capable of binding different classes of targets with high affinity and selectivity. They are particularly attractive as affinity probes in multiplexed quantitative analysis of proteins. Aptamers are typically selected from large libraries of random DNA sequences in a general approach termed systematic evolution of ligands by exponential enrichment (SELEX). SELEX involves repetitive rounds of two processes: (i) partitioning of aptamers from non-aptamers by an affinity method and (ii) amplification of aptamers by the polymerase chain reaction (PCR). New partitioning methods, which are characterized by exceptionally high efficiency of partitioning, have been recently introduced. For the overall SELEX procedure to be efficient, the high efficiency of new partitioning methods has to be matched by high efficiency of PCR. Here we present the first detailed study of PCR amplification of random DNA libraries used in aptamer selection. With capillary electrophoresis as an analytical tool, we found fundamental differences between PCR amplification of homogeneous DNA templates and that of large libraries of random DNA sequences. Product formation for a homogeneous DNA template proceeds until primers are exhausted. For a random DNA library as a template, product accumulation stops when PCR primers are still in excess of the products. The products then rapidly convert to by-products and virtually disappear after only 5 additional cycles of PCR. The yield of the products decreases with the increasing length of DNA molecules in the library. We also proved that the initial number of DNA molecules in PCR mixture has no effect on the by-products formation. While the increase of the Taq DNA polymerase concentration in PCR mixture selectively increases the yield of PCR products. Our findings suggest that standard procedures of PCR amplification of homogeneous DNA samples cannot be transferred to PCR amplification of random DNA libraries: to ensure efficient SELEX, PCR has to be optimized for the amplification of random DNA libraries.  相似文献   

19.
See what you eat—broad GMO screening with microarrays   总被引:1,自引:0,他引:1  
Despite the controversy of whether genetically modified organisms (GMOs) are beneficial or harmful for humans, animals, and/or ecosystems, the number of cultivated GMOs is increasing every year. Many countries and federations have implemented safety and surveillance systems for GMOs. Potent testing technologies need to be developed and implemented to monitor the increasing number of GMOs. First, these GMO tests need to be comprehensive, i.e., should detect all, or at least the most important, GMOs on the market. This type of GMO screening requires a high degree of parallel tests or multiplexing. To date, DNA microarrays have the highest number of multiplexing capabilities when nucleic acids are analyzed. This trend article focuses on the evolution of DNA microarrays for GMO testing. Over the last 7 years, combinations of multiplex PCR detection and microarray detection have been developed to qualitatively assess the presence of GMOs. One example is the commercially available DualChip® GMO (Eppendorf, Germany; http://www.eppendorf-biochip.com), which is the only GMO screening system successfully validated in a multicenter study. With use of innovative amplification techniques, promising steps have recently been taken to make GMO detection with microarrays quantitative.
Figure
EU-validated GMO screening microarray  相似文献   

20.
Miniaturized isothermal nucleic acid amplification, a review   总被引:1,自引:0,他引:1  
Asiello PJ  Baeumner AJ 《Lab on a chip》2011,11(8):1420-1430
Micro-Total Analysis Systems (μTAS) for use in on-site rapid detection of DNA or RNA are increasingly being developed. Here, amplification of the target sequence is key to increasing sensitivity, enabling single-cell and few-copy nucleic acid detection. The several advantages to miniaturizing amplification reactions and coupling them with sample preparation and detection on the same chip are well known and include fewer manual steps, preventing contamination, and significantly reducing the volume of expensive reagents. To-date, the majority of miniaturized systems for nucleic acid analysis have used the polymerase chain reaction (PCR) for amplification and those systems are covered in previous reviews. This review provides a thorough overview of miniaturized analysis systems using alternatives to PCR, specifically isothermal amplification reactions. With no need for thermal cycling, isothermal microsystems can be designed to be simple and low-energy consuming and therefore may outperform PCR in portable, battery-operated detection systems in the future. The main isothermal methods as miniaturized systems reviewed here include nucleic acid sequence-based amplification (NASBA), loop-mediated isothermal amplification (LAMP), helicase-dependent amplification (HDA), rolling circle amplification (RCA), and strand displacement amplification (SDA). Also, important design criteria for the miniaturized devices are discussed. Finally, the potential of miniaturization of some new isothermal methods such as the exponential amplification reaction (EXPAR), isothermal and chimeric primer-initiated amplification of nucleic acids (ICANs), signal-mediated amplification of RNA technology (SMART) and others is presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号