首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The development of a surface plasmon resonance (SPR) affinity biosensor based on DNA hybridisation is described. This biosensor has been applied to genetically modified organisms (GMOs) detection. Single stranded DNA (ssDNA) probes were immobilised on the sensor chip of an SPR device and the hybridisation between the immobilised probe and the complementary sequence (target) was monitored. The probe sequences were internal to the sequence of 35S promoter and NOS terminator which are inserted sequences in the genome of GMO regulating the transgene expression. The system has been optimised using synthetic oligonucleotides, then applied to real samples analysis. Samples, containing the transgenic target sequences, were amplified by polymerase chain reaction (PCR) and then detected with the SPR biosensor.  相似文献   

2.
Three different biosensors for detection of Genetically Modified Organisms (GMOs) are presented. The sensing principle is based on the affinity interaction between nucleic acids: the probe is immobilised on the sensor surface and the target analyte is free in solution. The immobilised probes are specific for most inserted sequences in GMOs: the promoter P35S and the terminator TNOS. Electrochemical methods with screen-printed electrodes, piezoelectric and optical (SPR) transduction principles were applied.  相似文献   

3.
Three different biosensors for detection of Genetically Modified Organisms (GMOs) are presented. The sensing principle is based on the affinity interaction between nucleic acids: the probe is immobilised on the sensor surface and the target analyte is free in solution. The immobilised probes are specific for most inserted sequences in GMOs: the promoter P35S and the terminator TNOS. Electrochemical methods with screen-printed electrodes, piezoelectric and optical (SPR) transduction principles were applied.  相似文献   

4.
Current screening and event-specific polymerase chain reaction (PCR) assays for the detection and identification of genetically modified organisms (GMOs) in samples of unknown composition or for the detection of non-regulated GMOs have limitations, and alternative approaches are required. A transgenic DNA fingerprinting methodology using restriction enzyme digestion, adaptor ligation, and nested PCR was developed where individual GMOs are distinguished by the characteristic fingerprint pattern of the fragments generated. The inter-laboratory reproducibility of the amplified fragment sizes using different capillary electrophoresis platforms was compared, and reproducible patterns were obtained with an average difference in fragment size of 2.4 bp. DNA insert fingerprints for 12 different maize events, including two maize hybrids and one soy event, were generated that reflected the composition of the transgenic DNA constructs. Once produced, the fingerprint profiles were added to a database which can be readily exchanged and shared between laboratories. This approach should facilitate the process of GMO identification and characterization.  相似文献   

5.
This tutorial review will address the issue of DNA determination in food by using Peptide Nucleic Acid (PNA) probes with different technological platforms, with a particular emphasis on the applications devoted to food authentication. After an introduction aimed at describing PNAs structure, binding properties and their use as genetic probes, the review will then focus specifically on the use of PNAs in the field of food analysis. In particular, the following issues will be considered: detection of genetically modified organisms (GMOs), of hidden allergens, of microbial pathogens and determination of ingredient authenticity. Finally, the future perspectives for the use of PNAs in food analysis will be briefly discussed according to the most recent developments.  相似文献   

6.
Despite the controversies surrounding genetically modified organisms (GMOs), the production of GM crops is increasing, especially in developing countries. Thanks to new technologies involving genetic engineering and unprecedented access to genomic resources, the next decade will certainly see exponential growth in GMO production. Indeed, EU regulations based on the precautionary principle require any food containing more than 0.9% GM content to be labeled as such. The implementation of these regulations necessitates sampling protocols, the availability of certified reference materials and analytical methodologies that allow the accurate determination of the content of GMOs. In order to qualify for the validation process, a method should fulfil some criteria, defined as “acceptance criteria” by the European Network of GMO Laboratories (ENGL). Several methods have recently been developed for GMO detection and quantitation, mostly based on polymerase chain reaction (PCR) technology. PCR (including its different formats, e.g., double competitive PCR and real-time PCR) remains the technique of choice, thanks to its ability to detect even small amounts of transgenes in raw materials and processed foods. Other approaches relying on DNA detection are based on quartz crystal microbalance piezoelectric biosensors, dry reagent dipstick-type sensors and surface plasmon resonance sensors. The application of visible/near-infrared (vis/NIR) spectroscopy or mass spectrometry combined with chemometrics techniques has also been envisaged as a powerful GMO detection tool. Furthermore, in order to cope with the multiplicity of GMOs released onto the market, the new challenge is the development of routine detection systems for the simultaneous detection of numerous GMOs, including unknown GMOs.  相似文献   

7.
Primers and probes were developed for the element-specific detection of cry1A.105 and cry2Ab2 genes, based on their DNA sequence as present in GM maize MON89034. Cry genes are present in many genetically modified (GM) plants and they are important targets for developing GMO element-specific detection methods. Element-specific methods can be of use to screen for the presence of GMOs in food and feed supply chains. Moreover, a combination of GMO elements may indicate the potential presence of unapproved GMOs (UGMs). Primer-probe combinations were evaluated in terms of specificity, efficiency and limit of detection. Except for specificity, the complete experiment was performed in 9 PCR runs, on 9 different days and by testing 8 DNA concentrations. The results showed a high specificity and efficiency for cry1A.105 and cry2Ab2 detection. The limit of detection was between 0.05 and 0.01 ng DNA per PCR reaction for both assays. These data confirm the applicability of these new primer-probe combinations for element detection that can contribute to the screening for GM and UGM crops in food and feed samples.  相似文献   

8.
See what you eat—broad GMO screening with microarrays   总被引:1,自引:0,他引:1  
Despite the controversy of whether genetically modified organisms (GMOs) are beneficial or harmful for humans, animals, and/or ecosystems, the number of cultivated GMOs is increasing every year. Many countries and federations have implemented safety and surveillance systems for GMOs. Potent testing technologies need to be developed and implemented to monitor the increasing number of GMOs. First, these GMO tests need to be comprehensive, i.e., should detect all, or at least the most important, GMOs on the market. This type of GMO screening requires a high degree of parallel tests or multiplexing. To date, DNA microarrays have the highest number of multiplexing capabilities when nucleic acids are analyzed. This trend article focuses on the evolution of DNA microarrays for GMO testing. Over the last 7 years, combinations of multiplex PCR detection and microarray detection have been developed to qualitatively assess the presence of GMOs. One example is the commercially available DualChip® GMO (Eppendorf, Germany; http://www.eppendorf-biochip.com), which is the only GMO screening system successfully validated in a multicenter study. With use of innovative amplification techniques, promising steps have recently been taken to make GMO detection with microarrays quantitative.
Figure
EU-validated GMO screening microarray  相似文献   

9.
GMO quantification: valuable experience and insights for the future   总被引:1,自引:0,他引:1  
Cultivation and marketing of genetically modified organisms (GMOs) have been unevenly adopted worldwide. To facilitate international trade and to provide information to consumers, labelling requirements have been set up in many countries. Quantitative real-time polymerase chain reaction (qPCR) is currently the method of choice for detection, identification and quantification of GMOs. This has been critically assessed and the requirements for the method performance have been set. Nevertheless, there are challenges that should still be highlighted, such as measuring the quantity and quality of DNA, and determining the qPCR efficiency, possible sequence mismatches, characteristics of taxon-specific genes and appropriate units of measurement, as these remain potential sources of measurement uncertainty. To overcome these problems and to cope with the continuous increase in the number and variety of GMOs, new approaches are needed. Statistical strategies of quantification have already been proposed and expanded with the development of digital PCR. The first attempts have been made to use new generation sequencing also for quantitative purposes, although accurate quantification of the contents of GMOs using this technology is still a challenge for the future, and especially for mixed samples. New approaches are needed also for the quantification of stacks, and for potential quantification of organisms produced by new plant breeding techniques.  相似文献   

10.
Progress in genetic engineering has led to the introduction of genetically modified organisms (GMOs) whose genomes have been altered by the integration of a novel sequence conferring a new trait. To allow consumers an informed choice, many countries require food products to be labeled if the GMO content exceeds a certain threshold. Consequently, the development of analytical methods for GMO screening and quantification is of great interest. Exponential amplification by the polymerase chain reaction (PCR) remains a central step in molecular methods of GMO detection and quantification. In order to meet the challenge posed by the continuously increasing number of GMOs, various multiplex assays have been developed for the simultaneous amplification and/or detection of several GMOs. Classical agarose gel electrophoresis is being replaced by capillary electrophoresis (CE) systems, including CE chips, for the rapid and automatable separation of amplified fragments. Microtiter well-based hybridization assays allow high-throughput analysis of many samples in a single plate. Microarrays have been introduced in GMO screening as a technique for the simultaneous multianalyte detection of amplified sequences. Various types of biosensors, including surface plasmon resonance sensors, quartz crystal microbalance piezoelectric sensors, thin-film optical sensors, dry-reagent dipstick-type sensors and electrochemical sensors were introduced in GMO screening because they offer simplicity and lower cost. GMO quantification is performed by real-time PCR (rt-QPCR) and competitive PCR. New endogenous reference genes have been validated. rt-QPCR is the most widely used approach. Multiplexing is another trend in this field. Strategies for high-throughput multiplex competitive quantitative PCR have been reported.  相似文献   

11.
The use of genetically modified organisms (GMOs) as food and in food products is becoming more and more widespread. Polymerase chain reaction (PCR) technology is extensively used for the detection of GMOs in food products in order to verify compliance with labeling requirements. In this paper, we present a novel close-loop ferrofluid-driven PCR microchip for rapid amplification of GMOs. The microchip was fabricated in polymethyl methacrylate by CO2 laser ablation and was integrated with three temperature zones. PCR solution was contained in a circular closed microchannel and was driven by magnetic force generated by an external magnet through a small oil-based ferrofluid plug. Successful amplification of genetically modified soya and maize were achieved in less than 13 min. This PCR microchip combines advantages of cycling flexibility and quick temperature transitions associated with two existing microchip PCR techniques, and it provides a cost saving and less time-consuming way to conduct preliminary screening of GMOs. Figure Schematic of the circular ferrofluid-driven PCR microchip  相似文献   

12.
An immobilisation procedure based on the direct coupling of thiolated probes (Probe-C6-SH) to bare gold sensor surfaces has been compared with a reference immobilisation method, based on the coupling of biotinylated probes onto a streptavidin-coated dextran-modified surface. The instrumentations used were a quartz crystal microbalance (QCM) and the optical instruments Biacore X and Spreeta based on surface plasmon resonance (SPR). The performances of the DNA-based sensors resulting from direct coupling of thiolated DNA probes onto electrodes of quartz crystals or gold SPR-chips have been studied in terms of the main analytical parameters, i.e. selectivity, sensitivity, reproducibility, etc. In particular, the two immobilisation approaches have been applied to the analysis of oligonucleotides, DNA amplified by polymerase chain reaction (PCR) and genomic DNA enzymatically digested.  相似文献   

13.
《Analytical letters》2012,45(15):3093-3125
ABSTRACT

There is an increasing need for analytical methods for the detection of genetically modified organisms (GMOs) detection in food due to the growth of use of GMOs, or their derivatives, in the food industry. This paper aims to briefly introduce the reader to GMOs, to describe the state of the art in detection methods for GMOs, and to provide the reader with the associated terminology, mainly borrowed from molecular biology. The main characteristics of GMO are illustrated and future developments using the biosensor approach for detection are presented.  相似文献   

14.
NAIMA as a solution for future GMO diagnostics challenges   总被引:1,自引:0,他引:1  
In the field of genetically modified organism (GMO) diagnostics, real-time PCR has been the method of choice for target detection and quantification in most laboratories. Despite its numerous advantages, however, the lack of a true multiplexing option may render real-time PCR less practical in the face of future GMO detection challenges such as the multiplicity and increasing complexity of new transgenic events, as well as the repeated occurrence of unauthorized GMOs on the market. In this context, we recently reported the development of a novel multiplex quantitative DNA-based target amplification method, named NASBA implemented microarray analysis (NAIMA), which is suitable for sensitive, specific and quantitative detection of GMOs on a microarray. In this article, the performance of NAIMA is compared with that of real-time PCR, the focus being their performances in view of the upcoming challenge to detect/quantify an increasing number of possible GMOs at a sustainable cost and affordable staff effort. Finally, we present our conclusions concerning the applicability of NAIMA for future use in GMO diagnostics.  相似文献   

15.
Competent laboratories monitor genetically modified organisms (GMOs) and products derived thereof in the food and feed chain in the framework of labeling and traceability legislation. In addition, screening is performed to detect the unauthorized presence of GMOs including asynchronously authorized GMOs or GMOs that are not officially registered for commercialization (unknown GMOs). Currently, unauthorized or unknown events are detected by screening blind samples for commonly used transgenic elements, such as p35S or t-nos. If (1) positive detection of such screening elements shows the presence of transgenic material and (2) all known GMOs are tested by event-specific methods but are not detected, then the presence of an unknown GMO is inferred. However, such evidence is indirect because it is based on negative observations and inconclusive because the procedure does not identify the causative event per se. In addition, detection of unknown events is hampered in products that also contain known authorized events. Here, we outline alternative approaches for analytical detection and GMO identification and develop new methods to complement the existing routine screening procedure. We developed a fluorescent anchor-polymerase chain reaction (PCR) method for the identification of the sequences flanking the p35S and t-nos screening elements. Thus, anchor-PCR fingerprinting allows the detection of unique discriminative signals per event. In addition, we established a collection of in silico calculated fingerprints of known events to support interpretation of experimentally generated anchor-PCR GM fingerprints of blind samples. Here, we first describe the molecular characterization of a novel GMO, which expresses recombinant human intrinsic factor in Arabidopsis thaliana. Next, we purposefully treated the novel GMO as a blind sample to simulate how the new methods lead to the molecular identification of a novel unknown event without prior knowledge of its transgene sequence. The results demonstrate that the new methods complement routine screening procedures by providing direct conclusive evidence and may also be useful to resolve masking of unknown events by known events.  相似文献   

16.
This paper presents results of a collaborative trial study (IUPAC project No. 650/93/97) involving 29 laboratories in 13 countries applying a method for detecting genetically modified organisms (GMOs) in food. The method is based on using the polymerase chain reaction to determine the 35S promotor and the NOS terminator for detection of GMOs. reference materials were produced that were derived from genetically modified soy beans and maize. Correct identification of samples containing 2% GMOs is achievable for both soy beans and maize. For samples containing 0.5% genetically modified soy beans, analysis of the 35S promotor resulted also in a 100% correct classification. However, 3 false-negative results (out of 105 samples analyzed) were reported for analysis of the NOS terminator, which is due to the lower sensitivity of this method. Because of the bigger genomic DNA of maize, the probability of encountering false-negative results for samples containing 0.5% GMOs is greater for maize than for soy beans. For blank samples (0% GMO), only 2 false-positive results for soy beans and one for maize were reported. These results appeared as very weak signals and were most probably due to contamination of laboratory equipment.  相似文献   

17.
 The detection of genetically modified organisms (GMOs) by the polymerase chain reaction (PCR) is a complex multiparameter problem. Therefore, a number of critical issues in respect to quality control need to be considered. For practical purposes, the PCR process itself can be divided into three subprocesses: template isolation and reaction setup (pre-PCR), PCR reaction and detection of amplification products, and data evaluation (post-PCR). Crucial factors for the pre-PCR process are the following: homogeneity of the sample to be analysed, performance of template isolation and purification in terms of yield and purity, standardized process for the estimation of concentrations of genomic DNA and all reagents used in the reaction. For the PCR itself, crucial factors to be controlled are: setup of reactions, batch to batch variations of reagents, temperature-time programs used for the PCR amplification, and the performance of different types of hardware (e.g. different brands of thermocyclers). The crucial factor for the post-PCR process is the detection of the amplification products of the PCR. The tremendous sensitivity of PCR methods requires a careful and consequent separation of the three processes in terms of hardware, laboratory space and sample handling. The avoidance of contamination is one of the most critical factors. The goal of quality assurance measures must be to ensure appropriate results at maximum sensitivity. The complexity of any PCR system used for the detection of GMOs leads to the requirement of a careful validation process for any laboratory using such methods. For qualitative analyses crucial validation parameters are: specificity, selectivity, repeatability, intermediate precision, reproducibility, limit of detection and robustness. Received: 5 October 1998 / Accepted: 22 February 1999  相似文献   

18.
New approaches in GMO detection   总被引:3,自引:0,他引:3  
The steady rate of development and diffusion of genetically modified plants and their increasing diversification of characteristics, genes and genetic control elements poses a challenge in analysis of genetically modified organisms (GMOs). It is expected that in the near future the picture will be even more complex. Traditional approaches, mostly based on the sequential detection of one target at a time, or on a limited multiplexing, allowing only a few targets to be analysed at once, no longer meet the testing requirements. Along with new analytical technologies, new approaches for the detection of GMOs authorized for commercial purposes in various countries have been developed that rely on (1) a smart and accurate strategy for target selection, (2) the use of high-throughput systems or platforms for the detection of multiple targets and (3) algorithms that allow the conversion of analytical results into an indication of the presence of individual GMOs potentially present in an unknown sample. This paper reviews the latest progress made in GMO analysis, taking examples from the most recently developed strategies and tools, and addresses some of the critical aspects related to these approaches.  相似文献   

19.
A typical TaqMan? real-time PCR probe contains a 5'-fluorescent dye and a 3'-quencher. In the course of the amplification, the probe is degraded starting from the 5'-end, thus releasing fluorescent dye. Some fluorophores (including fluorescein) are known to be prone to self-quenching when located near each other. This work is aimed at studying dye-dye and dye-quencher interactions in multiply modified DNA probes. Twenty-one fluorogenic probes containing one and two fluoresceins (FAM), or a FAM-JOE pair, and one or two BHQ1 quenchers were synthesized using non-nucleoside reagents and "click chemistry" post-modification on solid phase and in solution. The probes were tested in real-time PCR using an ~300-bp-long natural DNA fragment as a template. The structural prerequisites for lowering the probe background fluorescence and increasing the end-plateau fluorescence intensity were evaluated and discussed.  相似文献   

20.
A novel surface enzymatic reaction scheme that amplifies the optical response of RNA microarrays to the binding of complementary DNA is developed for the direct detection and analysis of genomic DNA. The enzyme RNase H is shown to selectively and repeatedly destroy RNA from DNA-RNA heteroduplexes on gold surfaces; when used in conjunction with the label-free technique of surface plasmon resonance (SPR) imaging, DNA oligonucleotides can be detected at a concentration of 1 fM. This enzymatically amplified SPR imaging methodology is then utilized to detect and identify the presence of the TSPY gene in human genomic DNA without PCR amplification.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号