首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 937 毫秒
1.
根据反相液相色谱保留模型和Martin方程, 采用热力学方法导出了一组包括各种色谱参数(如柱温、流动相中有机改性剂浓度以及溶质、溶剂和键合相表面烷基配体中的碳数)的线性保留方程。利用这组方程能够解释反相液相色谱中各种线性保留规律和实验现象, 并预测和实验验证了多种文献未报道的线性规律。  相似文献   

2.
填充柱超临界流体色谱系统中的溶剂效应   总被引:2,自引:0,他引:2  
陆峰  刘荔荔  吴玉田 《色谱》2000,18(2):155-157
 考察了填充柱超临界流体色谱法 (SFC)中的样品溶剂及连续进样等因素对化合物保留行为变化的影响规律。以超临界 CO2 或含低体积分数甲醇的 CO2 为流动相时 ,氨基柱上组分的保留时间随着样品溶剂的极性增大而增大 ,而溶剂对 C1 8柱上组分的保留时间影响不大 ;在 C1 8柱上 ,溶剂对连续进样的后续效应不强 ;而在氨基柱上 ,甲醇溶液的后续效应比丙酮、氯仿溶液的后续效应强。当甲醇的体积分数大于 1 .0 %时 ,溶剂的效应明显减弱。这种变化规律对填充柱 SFC的合理进样并获得重现性良好的色谱数据具有实际意义。  相似文献   

3.
Electrostatic ion chromatography, also known as zwitterionic ion chromatography, has been predominantly used for the analysis of anions. Consequently, separation mechanisms proposed for this technique have been based on anion retention data obtained using a sulfobetaine-type surfactant-coated column. A comprehensive cation retention data set has been obtained on a C18 column coated with the zwitterionic surfactant N-tetradecylphosphocholine (which has the negatively and positively charged functional groups reversed in comparison to the sulfobetaine surfactants), with mobile phases being varied systematically in the concentration and species of both the mobile-phase anion and cation. A retention mechanism based on both an ion exclusion effect and a direct (chaotropic) interaction with the inner negative charge on the zwitterion is proposed for the retention of cations. Despite the relatively low chaotropic nature of cations compared with anions, the retention data shows that cations are retained in this system predominantly due to a chaotropic interaction with the inner charge, analogous to anions in a system where the C18 column is coated with a sulfobetaine-type surfactant. The retention of an analyte cation, and the effect of the mobile-phase anion and cation, can be predicted by the relative positions of these species on the Hofmeister (chaotropic) series.  相似文献   

4.
5.
Regarding hydrophilic interaction chromatography and normal phase liquid chromatography, RPLC is another choice used to separate polar compounds with the improvement of polar-modified C18 stationary phase. In this study, a method using conventional C18 column coupled with polar-copolymerized C18 column was successfully developed for the separation and purification of polar compounds from Radix isatidis, which is one of the most commonly used traditional Chinese medicines (TCMs). An XTerra MS C18 column was used to fractionate the extract of R. isatidis and a homemade polar-copolymerized C18 column was utilized for the final purification due to its good separation selectivity and high resolution for polar compounds. The established purification system demonstrated good orthogonality for the polar compounds. As a result, ten compounds were purified and three of them were identified as 3-methyl-5-vinyloxazolidin-2-one (compound A), 5-hydroxymethyl-2-furaldehyde (compound B) and 3-methylfuran-2-carboxylic acid (compound G) based on the MS, IR and extensive NMR data, respectively. It was demonstrated to be a feasible and powerful technique for the purification of polar compounds under RPLC mode and more chemical information of TCMs will be obtained to interpret the efficiency of TCMs.  相似文献   

6.
A fast, sensitive high-performance liquid chromatographic method has been developed for the separation and quantitation of biliary bile pigments; this utilizes a C18 reversed-phase column with two solvents, a buffer and an organic solvent, which were changed in a linear gradient from a polar to a less polar combination. Nine glycosidic conjugates of bilirubin as well as unconjugated bilirubin and a suitable internal standard, unconjugated mesobilirubin IX alpha, were all separated to baseline by gradient elution; the species eluted in a polar to less polar fashion. Increasing the molarity of the solvent decreased the binding of non-glucuronide pigments to the column, with a decrease in their retention times, whereas for bilirubin monoglucuronide they increased. Decrease in pH, similarly, preferentially increased bilirubin monoglucuronide retention times.  相似文献   

7.
8.
通过十八烷基胺的氨基与二醛微晶纤维素的醛基共价键合,制备了基于二醛微晶纤维素(DMCC)官能化C18的新型反相/亲水色谱固定相(C18-DMCC/SiO2),该色谱固定相被用于反相色谱(RPLC)和亲水相互作用色谱(HILIC)模式。C18-DMCC/SiO2色谱柱展现了良好的疏水选择性和芳香选择性,在反相色谱模式下可分离烷基苯和多环芳烃(PAHs)。苯胺类、酚类和糖苷类等极性化合物被用于评估该色谱柱在反相色谱模式下的极性选择性,商品C18柱作对照柱,色谱评价结果令人满意。核酸碱基被用于评估C18-DMCC/SiO2色谱柱的亲水色谱性能。通过考察有机溶剂含量对分析物保留的影响,发现该新型色谱固定相具有反相/亲水色谱的典型特征。  相似文献   

9.
刘小兰  高薇  梁超  乔俊琴  王康  练鸿振 《色谱》2021,39(11):1230-1238
反相液相色谱(RPLC)是测定正辛醇/水分配系数(log P)的有效方法,但由于缺少同类型模型化合物,RPLC在测定强离解化合物的log P时遇到挑战。该文在硅胶基质C18色谱柱上,采用离子抑制反相液相色谱(IS-RPLC)和离子对反相液相色谱(IP-RPLC)分别对中性化合物、酚酸、羧酸、磺酸及部分两性化合物的保留行为进行了系统研究。在IS-RPLC模式下,利用中性化合物、弱离解的酚酸和苯羧酸作为模型化合物,建立了表观正辛醇/水分配系数(log D)与纯水相保留因子对数值(log kw)的定量结构-保留行为关系(QSRR)模型,测定了19种离解化合物的log D值,作为后续IP-RPLC的模型化合物及验证化合物。在IP-RPLC模式下,将中性、弱离解和强离解化合物作为混合模型组,以溶质静电荷ne、氢键酸碱性参数AB为桥梁,建立了线性良好的log D-log kw-IP模型,采用3种不同类型的离解化合物进行了外部验证实验,预测值误差低于10%,证实了模型的可靠性。在此基础上,预测了8种强离解化合物的log D7.0值(pH 7.0条件下的log D值)。研究表明,利用结构相关参数沟通不同类型的模型化合物,是实现IP-RPLC测定强离解化合物log D值的一种行之有效的方法。与聚乙烯醇基质色谱柱相比,通用型的硅胶基质色谱柱上尽管存在着更多的次级作用,但可以为强离解化合物log D的测定提供更灵活的选择。  相似文献   

10.
Two new perfluoroalkyl-modified stationary phases were prepared and compared with two commercially available perfluorinated stationary phases (Fluophase RP and Fluophase Pentafluorophenyl) and a C18-RP column with respect to retention times of an array of perfluoroalkyl-tagged and untagged molecules. A few highly lipophilic compounds were also included in the study. They showed high retention times on C18-RP columns, but not on perfluorinated support materials. Perfluoroalkyl-tagged compounds revealed a weak interaction with the pentafluorophenyl-modified support. The interaction between perfluoroalkyl-tagged compounds and perfluoroalkyl-modified stationary phases was strong, and dependent on the chain length of the perfluoro tags. Surprisingly, there was only a small difference between the retention times of perfluorinated compounds on C18-RP and C6F13-modified support. Fluorous-fluorous interactions became prevalent only with C8F17-tagged compounds on C8F17 functionalized silica gel. Compounds with two perfluoro tags showed a drastic increase in retention time, which might be due to a cooperative effect. These results demonstrate the uniqueness of fluorous-fluorous interactions based on linear perfluoroalkyl chains and open up possibilities for the design of new perfluoro tags for purifications and noncovalent attachments of catalysts or biomolecules on perfluorinated solid supports.  相似文献   

11.
A systematic investigation was undertaken into the relative separation performance of five reversed-phase chromatography columns including some commercially new hybrid packed columns for a series of polycarboxylic acids and polyphenol compounds. Information theory (IT) and factor analysis (FA), together with a basic evaluation of retention information (band shape, retention factor and elution order) were used to compare four columns to a conventional C18 column. The results revealed very little difference in retention behaviour between the Phenomenex Aqua C18 column, the Waters XTerra RP C18 column, and the conventional Phenomenex Luna C18 column. However, there were notable differences in the retention processes between the Phenomenex Synergi polar-RP column, which is an ether-linked phenyl base with polar endcapping, and the Luna C18 column. The most significant differences were observed between the Luna C18 column and a Phenomenex Luna Cyano column. However, the limited degree of retention of the polycarboxylic acids and polyphenol compounds on the Luna Cyano column permits only limited use for the separation of these types of compounds. Overall, the Phenomenex Synergi polar-RP column exhibited the best performance for the separation of the test solutes compared to that of the conventional C18 column, with IT yielding an Informational Similarity of 0.99 and FA a moderate correlation coefficient of 0.70. The Phenomenex Synergi polar-RP column gave the best peak shape and offered substantial selectivity differences thereby providing a good alternative over the conventional C18 column for separating polycarboxylic acids and polyphenols.  相似文献   

12.
The organic solvent content and the pH in the mobile phase are the usual main factors in reversed-phase liquid chromatographic separations, owing to their strong effects on retention and/or selectivity. Temperature is often neglected. However, even in cases where the impact of this factor on selectivity is minor, the reduction in analysis time is still an interesting reason to consider it. In addition, ionisable compounds may exhibit selectivity changes, owing to the interaction of organic solvent and/or temperature with pH. The separation of ionisable compounds (nine diuretics: bendroflumethiazide, benzthiazide, bumetanide, chlorthalidone, furosemide, piretanide, probenecid, trichloromethiazide and xipamide, and two beta-blockers: oxprenolol and propranolol) exhibiting different acid-base behaviour was studied. The compounds were tested in a Zorbax SB C18 column under a wide range of conditions: 25-45% (v/v) acetonitrile, pH 3-7 and 20-50 degrees C. Models considering two factors (organic solvent/pH and temperature/pH), and three factors (organic solvent/temperature/pH) were developed from a previously reported equation, which considers the polarity contributions of solute, stationary and mobile phases. This allowed a comprehensive method to predict the retention of the 11 compounds, the modification of their acid-base behaviour (i.e. determination of protonation constants and shifts of the retention versus pH curves), and the selectivity changes within the studied factor ranges.  相似文献   

13.
A sensitive and simple liquid chromatography-tandem mass spectrometry method for the determination of midazolam and 1'-hydroxymidazolam in human plasma has been developed and validated with a dynamic range of 0.1-250 ng/mL. The analysis was based on semi-automated liquid-liquid extraction followed by evaporation of the extraction solvent, reconstitution and chromatography on a reversed-phase C(18) column. The mobile phase consists of 5 mm ammonium acetate and methanol and runs in gradient at a flow rate of 0.25 mL/min with column temperature of approximately 20 degrees C. The entire column effluent was transferred into the LC-MS/MS interface operated in positive electrospray ionization mode. The chromatographic run time was 4.3 min per injection, with retention times for midazolam, 1'-hydroxymidazolaml and the internal standard, triazolam, of 2.5, 2.3 and 2.1 min, respectively. The intra-day and inter-day precision (RSD %) and accuracy (bias %) of the quality control samples were <15.0% and within +/-13%, respectively. The current method has been applied to a clinical drug-drug interaction study in human.  相似文献   

14.
选用CAPCELL PAK C18色谱柱为分离柱,柱温为30℃,进样体积为10.0μL,并用不同比例的(A)甲醇、(B)四氢呋喃和(C)0.008 2mol·L^-1高氯酸溶液的混合液作为流动相,按程序梯度洗脱模式对市售防晒产品中所用的15种防晒剂的标准品进行色谱分离,并在波长311nm处进行紫外检测。实样分析时,称取样品0.25g,用甲醇、四氢呋喃、水和高氯酸(体积比为250∶450∶300∶0.2)的混合液(以下简称混合溶剂)15 mL超声提取30 min,用混合溶剂定容至25.0mL,离心10min,分取上清液1.0mL,加入混合溶剂定容至10.0mL,经0.45μm滤膜过滤,取滤液按仪器工作条件进行高效液相色谱分析。结果表明:所测定的15种防晒剂在一定的质量浓度范围内与其对应的峰面积呈线性关系。选定其中的二苯酮-3为参照物,并根据其余14种化合物的质量浓度和峰面积计算了各化合物的相对校正因子和相对保留时间等参数,确定了用一测多评法(QAMS)测定防晒产品中15种防晒剂的条件。还对色谱柱的型号、色谱仪器的型号以及柱温、进样量等对相对校正因子和保留时间可能产生影响的因素进行了系统试验。证明了在选定的色谱柱型号的前提下,用QAMS方法可实现防晒产品中15种防晒剂含量的同时测定。应用QAMS方法测定了6个批次防晒产品中的防晒剂含量,所得结果与用标准曲线法计算的结果基本一致,表明QAMS方法在降低检测成本和节省检测时间方面效果显著。  相似文献   

15.
Effects of solvent composition and ligand variation on the retention of organometallic compounds have been studied using an amino, an octadecylsilica (ODS) and a beta-cyclodextrin (beta-CD) bonded phase column in either a normal-phase or a reversed-phase mode. The retention behavior for the organometallic compounds with the amino column can be rationalized using the displacement model. The "apparent" molecular areas are greater for compounds capable of strong hydrogen bonding. The retention in the ODS column roughly follows an argument based on the expected solubility behavior while mixed retention mechanisms are involved for the solubility behavior while mixed retention mechanisms are involved for the beta-CD column, i.e. both inclusion process and solubility or solvophobic interactions are possibly operative.  相似文献   

16.
Cao X  Pei H  Huo L  Hu G  Ito Y 《Journal of separation science》2011,34(19):2611-2617
An improved type-J counter-current chromatography (CCC) planet centrifuge with two spiral tube columns (volume 2×15 mL, β value 0.3-0.7, tubing 0.8 mm id) was developed and evaluated for its retention ability of four typical different solvent systems including heptane-methanol (1:1, v/v) (A), hexane-ethyl acetate-methanol-water (1:1:1:1, v/v) (B), n-butanol-acetic acid-water (4:1:5, v/v) (C), PEG1000-K(2)HPO(4)-water (12.5:12.5:75, w/w) (D) under eight different operation modes. The results indicated that the spiral tube column could significantly increase the retention of four typical solvent systems compared with a traditional multilayer coil column with similar parameters (volume 35 mL, β value 0.3-0.7, tubing 0.8 mm id). The retention of stationary phase (S(f)) for the less polar system (A) and moderately polar solvent system (B) can be increased by about 10%, and for the polar system (C) and aqueous two-phase system (ATPS) (D) by 30-40%. The preliminary applications of this spiral tube column to the separation of small molecular compounds such as moderately polar theaflavins, polar anthocyanins and dipeptides were successful. Acceptable resolution can be obtained between cytochrome c and myoglobin, lysozyme and myoglobin when it was applied on protein separation; however, it still needs to be improved with regard to its column efficiency.  相似文献   

17.
化合物色谱保留参数与其三维结构关系的研究   总被引:2,自引:0,他引:2  
张燕玲  郭亦然  王耘  乔延江 《色谱》2005,23(3):223-228
利用比较分子场分析(CoMFA)方法,建立了烷基取代苯、氯代苯、多环芳烃和二硝基取代芳烃等4类结构相近的化合物在甲醇/水体系中反相C18柱上的保留参数a,c值与其三维结构之间关系的定量模型。前3类化合物所得到的3个模型的交叉验证相关系数q2均大于0.5,其中针对烷基取代苯、氯代苯所建立的两个模型的非交叉验证相关系数r2大于0.995,表明模型具有较好的预测能力。该研究结果对进一步开展化合物液相色谱保留参数与其三维结构关系的研究提供了思路和方法。  相似文献   

18.
Achievement of the highest separation efficiency and quick delivery of results are key requirements in liquid chromatography for enhancing productivity and reducing analysis cost, especially in the pharmaceutical industry. This work concerns two of the most popular current solutions to get fast separations: the use of a silica-based monolithic column (Chromolith Performance RP-18e) and a small-particle packed column (1.8-μm Zorbax Eclipse XDB-C18, which needs dedicated instruments allowing higher backpressures). Both columns succeeded in the full separation of phenols and β-adrenolytic drugs, which are compounds that interact with residual silanols, giving rise to wider peaks. The results were compared with those obtained with a special column designed to avoid silanol interaction, containing 5 μm particles (XTerra MS C18). Chromolith gave the shortest times at the expense of higher solvent consumption at the high flow rates needed. In contrast to other studies, comprehensive conclusions on the chromatographic performance, in terms of selectivity, peak shape, resolution, and analysis time, are derived from the inspection of the whole experimental domain using retention and peak shape modelling. In the literature, column comparison is usually carried out based on the performance for selected mobile phases (very often a single one), which offers deceiving results.  相似文献   

19.
A comparison of the adsorption isotherms of caffeine, theophylline and theobromine and the competitive adsorption of the three compounds on a C 18 column were investigated. The experimental parameters of the equilibrium isotherms were estimated by linear and nonlinear regression analyses. The linear equation as a function of the adsorption concentration of the single compound in its solution and the competitive adsorption of a single compound in a mixed solution were then determined. The adsorption equilibrium data were then correlated to the linear, Langmuir, Freundlich, Langmuir-Freundlich and stoichiometric displacement theory for adsorption(SDT-A) isotherm models. The mixed compounds of the three compounds were competitively adsorbed on the C 18 particles. The expression of stoichiometric displacement theory for adsorption was found to be more suitable for adsorption of methylxanthines on a C 18 column.  相似文献   

20.
常东亮  哈成勇 《色谱》1999,17(6):576-577
 摘要:研究了单萜/顺酐加成物及其酯化衍生物在OV-17和SE-30柱上的某些色谱性能和定量分析的线性相应关系。结果表明,这两种化合物在涂渍量为5%~10%的OV-17和SE-30柱上均能正常出峰;在峰形对称性和出峰时间上,OV-17柱具有优势。260℃以后,色谱峰面积与汽化温度无关。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号