首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Abstract

Retention volume of proteins increased or decreased with increasing phosphate buffer or neutral electrolyte concentrations in the mobile phase. This variation suppressed or accelerated by changing pH values in the mobile phase. The behavior of proteins can be interpreted by knowing isoelectric points (pI) of proteins and pKa value of the residual silanol groups on the surface of diol-bonded porous glasses. Positively charged surface of proteins below pH 8.0 (cytochrome c, lysozyme) retarded the elution by the ion-adsorption effects and negatively charged proteins around pH 7.0 (egg albumin, bovin serum albumin) eluted earlier than expected by the ion-exclusion effects. These effects suppressed by increasing phosphate buffer and neutral electrolyte concentrations in the mobile phase. Size-exclusion separation was attained in the mobile phase over 0.1 M phosphates and 0.1 M NaCl concentrations at pH 7.0. Mcllvaine buffer and Gomori buffer showed opposite action to proteins for retention comparing with Soerensen phosphate buffer. Potassium thiocyanate showed the different action for retention of proteins comparing with other neutral electrolytes and acted like sodium dodecyl sulphonate.  相似文献   

2.
A high-performance liquid chromatography (HPLC)/electrospray ionization mass spectrometry method for measuring drug-membrane interactions was developed using immobilized artificial membrane (IAM) fast-screening mini-columns. The HPLC mobile phase consisted of phosphate-buffered saline (i.e., 5.0 mM phosphate buffer at pH 7.4, 1.35 mM KCl, and 68.5 mM NaCl) and acetonitrile. This method facilitated the measurement of IAM retention time of over ten compounds in one experiment, significantly reducing analysis time compared with the earlier IAM-HPLC method. The particular electrospray source used demonstrated the ability to tolerate the high salt-containing nonvolatile buffer used for retention time measurement.  相似文献   

3.
The use of a C12 stationary phase with embedded polar group has been investigated for the separation of seven tetracyclines. The influence of pH, organic modifier, buffer, and temperature on the peak shape and analyte separation was discussed. It appears that all the chromatographic conditions had a great effect on both the resolution and peak shape whereas the elution order was not affected. The baseline separation with symmetrical peaks of the seven tetracyclines can be obtained with a mobile phase containing either 5 mM phosphate buffer pH 2.5/ACN (84:16 v/v) or 5 mM perchlorate buffer pH 2.5/ACN (75:25 v/v) at a temperature not exceeding 20 degrees C. This study reveals that the retention mechanism is ion-pairing.  相似文献   

4.
The separation of several insect oostatic peptides (IOPs) was achieved by using CEC with a strong-cation-exchange (SCX) stationary phase in the fused-silica capillary column of 75 microm id. The effect of organic modifier, ionic strength, buffer pH, applied voltage, and temperature on peptides' resolution was evaluated. Baseline separation of the studied IOPs was achieved using a mobile phase containing 100 mM pH 2.3 sodium phosphate buffer/water/ACN (10:20:70 v/v/v). In order to reduce the analysis time, experiments were performed in the short side mode where the stationary phase was packed for 7 cm only. The selection of the experimental parameters strongly influenced the retention time, resolution, and retention factor. An acidic pH was selected in order to positively charge the analyzed peptides, the pI's of which are about 3 in water buffer solutions. A good selectivity and resolution was achieved at pH <2.8; at higher pH the three parameters decreased due to reduced or even zero charge of peptides. The increase in the ionic strength of the buffer present in the mobile phase caused a decrease in retention factor for all the studied compounds due to the decreased interaction between analytes and stationary phase. Raising the ACN concentration in the mobile phase in the range 40-80% v/v caused an increase in both retention factor, retention time, and resolution due to the hydrophilic interactions of IOPs with free silanols and sulfonic groups of the stationary phase.  相似文献   

5.
Chromatographic methods have been developed for the separation of the three novel biocompatible iron chelators pyridoxal isonicotinoyl hydrazone (PIH), salicylaldehyde isonicotinoyl hydrazone (SIH), and pyridoxal 2-chlorobenzoyl hydrazone (o-108) from their synthetic precursors and iron chelates. The chromatographic analyses were achieved using analytical columns packed with 5 microm Nucleosil 120-5 C18. For the evaluation of all chelators in the presence of the synthetic precursors, EDTA was added to the mobile phase at a concentration of 2 mM. The best separation of PIH and its synthetic precursors was achieved using a mixture of phosphate buffer (0.01 M NaH2PO4, 5 mM 1-heptanesulfonic acid sodium salt; pH 3.0) and methanol (55:45, v/v). For separation of SIH and its synthetic precursors, the mobile phase was composed of 0.01 M phosphate buffer (pH 6.0) and methanol (60:40, v/v). o-108 was analyzed employing a mixture of 0.01 M phosphate buffer (pH 7.0), methanol, and acetonitrile (60:20:20, v/v/v). These mobile phases were slightly modified to separate each chelator from its iron chelate. Furthermore, a RP-TLC method has also been developed for fast separation of all compounds. The chromatographic methods described herein could be applied in the evaluation of purity and stability of these drug candidates.  相似文献   

6.
An automated high-performance liquid chromatographic (HPLC) method has been developed for measurement of 5-S-cysteinyl-DOPA in urine (DOPA = 3,4-dihydroxyphenylalanine). The urinary sample was injected into an HPLC boronate column. With a mobile phase of 0.1 M phosphate buffer containing 0.2 mM disodium ethylenediaminetetraacetate (Na2EDTA) (pH 6.0) mixed with methanol (9:1), 5-S-cysteinyl-DOPA was adsorbed while most other compounds were washed away. By column switching, the column flow was reversed and 5-S-cysteinyl-DOPA was desorbed by a mobile phase of 0.1 M formic acid and 0.2 mM Na2EDTA at pH 3.0 and chromatographed on a reversed-phase column. The precision, as estimated from repeated analysis of an urinary sample and from duplicate analysis of a number of samples, ranged from 1.4 to 5.2% (coefficient of variation), and the analytical recovery was 93 +/- 4.1%. The method is suitable for use in the clinical laboratory.  相似文献   

7.
The HPLC separation of arsenite, arsenate, methylarsonic acid and dimethylarsinic acid has been studied in the past but not in a systematic manner. The dependence of the retention times of these arsenic compounds on the pH of the mobile phase, on the concentration and the chemical composition of buffer solutions (phosphate, acetate, potassium hydrogen phthalate) and on the presence of sodium sulfate or nickel sulfate in the mobile phase was investigated using a Hamilton PRP-X100 anion-exchange column. With a flame atomic absorption detector and arsenic concentrations of at least 10 mg dm?3 all investigated mobile phases will separate the four arsenic compounds at appropriate pH values in the range 4–8. The shortest analysis time (?3 min) was achieved with a 0.006 mol dm?3 potassium hydrogen phthalate mobile phase at pH 4, the longest (?10 min) with 0.006 mol dm?3 sodium sulfate at pH 5.9 at a flow rate of 1.5 cm3 min?1. With a graphite furnace atomic absorption detector at the required, much lower, flow rate of ?0.2 cm3 min?1 acceptable separations were achievable only with the pH 6 phosphate buffer (0.03 mol dm?3) and the nickel sulfate solution (0.005 mol dm?3) as the mobile phase. To become detectable approximately 100 ng arsenic from each arsenic compound (100 μl injection) must be chromatographed with the phosphate buffer, and approximately 10 ng with the nickel sulfate solution.  相似文献   

8.
For the quantification of azasetron in rat plasma samples, a column-switching HPLC method was developed and validated. Following dilution of plasma samples with mobile phase A (17?mM potassium phosphate buffer (pH 3.0)) and simple protein precipitation by addition of perchloric acid (60%), the mixture was directly injected onto the pre-column. After endogenous plasma substances were eluted to waste, the analyte was transferred to the trap column by switching the system. Then, the analyte was back-flushed to the analytical column for separation with mobile phase B (a 22:78 v/v mixture of acetonitrile and 17?mM potassium phosphate buffer (pH 3.0)) and detected at 250?nm using a photodiode array detector. A linear standard curve was obtained in the concentration range of 10-800?ng/mL with the correlation coefficient (r) of 0.9998. The intra- and inter-day precision and accuracy values for azasetron were in the ranges of 0.3-12.9% and 89.7-101.4%, respectively. The method was valid in terms of specificity, precision, and accuracy. In addition, this efficient analytical method was successfully applied to determine plasma concentrations of azasetron following oral administration of azasetron at a dose of 4.0?mg/kg to rats.  相似文献   

9.
In this study, the separation of biologically active peptides on two zirconia-based phases, polybutadiene (PBD)-ZrO2 and polystyrene (PS)-ZrO2, and a silica-based phase C18 was compared. Basic differences in interactions on both types of phases led to quite different selectivity. The retention characteristics were investigated in detail using a variety of organic modifiers, buffers, and temperatures. These parameters affected retention, separation efficiency, resolution and symmetry of peaks. Separation systems consisting of Discovery PBD-Zr column and mobile phase composed of a mixture of acetonitrile and phosphate buffer, pH 2.0 (45:55, v/v) at 70 degrees C and Discovery PS-Zr with acetonitrile and phosphate buffer, pH 3.5 in the same (v/v) ratio at 40 degrees C were suitable for a good resolution of enkephalin related peptides. Mobile phase composed of acetonitrile and phosphate buffer, pH 5.0 (22:78, v/v) was appropriate for separation of enkephalins on Supelcosil C18 stationary phase.  相似文献   

10.
Retention factor, column efficiency and asymmetry factor were recorded for nine basic compounds on a number of RP-HPLC columns using phosphate and a variety of (MS-compatible) volatile mobile phase buffers of acid and neutral pH, in order to assess any effects of the buffer on performance. With formic or acetic acid, some phases gave partial or complete solute exclusion effects (reduced or negative k) compared with results using phosphate buffers at low pH. Despite its possible suppression of mass spectrometer sensitivity, trifluoroacetic acid was useful in enhancing retention times of relatively hydrophilic protonated bases, due to ion-pair effects. Peak shape was relatively poor on some pure silica-based ODS phases at pH 7 compared with results at acid pH. At low pH and at pH 7, ammonium and potassium phosphate gave very similar k, but the former may be preferable due to its volatile cation. Improved peak shapes, attributed to superior silanol masking effects, were obtained with ammonium phosphate at pH 7, but not at acid pH. Ammonium acetate gave acceptable peak shape at pH 7, but due to very limited buffer capacity, poor results were obtained for solutes having a pKa close to the mobile phase pH. Due to its instability, ammonium hydrogen carbonate is not a viable alternative buffer at pH 7.  相似文献   

11.
Vlase L  Imre S  Leucuta S 《Talanta》2005,66(3):659-663
A rapid and sensitive high-performance liquid chromatographic method has been developed for the simultaneous determination of the antidepressant fluoxetine and its active metabolite norfluoxetine in human plasma using paroxetine as internal standard. After liquid-liquid extraction, the compounds were separated on a C18 column using as mobile phase acetonitrile and 40 mM potassium dihydrogen phosphate buffer (pH 2.3) in the ratio 31:69 (v/v). The quantification of fluoxetine and norfluoxetine was made by fluorescence detection at Ex/Em 230/312 nm. The assay for each analyte was linear over the ranges 1-39 and 0.9-36 ng/ml, respectively. For both compounds intra- and inter-day accuracy and precision ranged between −7.9-12.4 and 0.7-14.7%, respectively. The method was applied to the analysis of plasma samples obtained from healthy subjects treated with one single oral dose of 40 mg fluoxetine.  相似文献   

12.
In order to separate the potential arsenite metabolites methylarsonous acid and dimethylarsinous acid from arsenite, arsenate, methylarsonic acid and dimethylarsinic acid, the pH‐dependent retention behaviour of all six arsenic compounds was studied on a Hamilton PRP‐X100 anion‐exchange column with 30 mM phosphate buffers (pH 5, 6, 7, 8 and 9) containing 20% (v/v) methanol as mobile phase and employing an inductively coupled plasma atomic emission spectrometer (ICP–AES) as the arsenic‐specific detector. Baseline separation of dimethylarsinic acid, methylarsonous acid, methylarsonic acid, arsenate and dimethylarsinous acid was achieved with a 30 mmol dm−3 phosphate buffer (pH 5)–methanol mixture (80:20, v/v) in 25 min. Arsenite is not baseline‐separated from dimethylarsinic acid under these conditions. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

13.
A procedure based on BIA Separations CIM DEAE anion-exchange chromatography was developed to separate double-stranded (ds) RNA of hypovirus infecting phytopathogenic fungus Cryphonectria parasitica. Using a linear gradient of 25 mM 4-morpholinepropanesulfonic acid (MOPS), pH 7.0 as a binding buffer, and 25 mM MOPS, 1.5 M NaCl, 0.1 mM EDTA, 15% isopropanol (v/v), pH 7.0 as an elution buffer, hypoviral dsRNA was additionally purified from nucleic acid species present in preparations partially purified by standard CF-11 cellulose chromatography. Moreover, crude phenol/chloroform extracts of the fungal tissue were also applied to monolithic supports and CIM DEAE chromatograms revealed clear evidence for hypoviral presence without CF-11 chromatography, nucleic acid precipitation, and electrophoresis.  相似文献   

14.
In this paper, we report for the first time an aptamer-based chiral stationary phase (CSP) able to resolve racemates of both target and various related compounds. The enantiomers of tyrosine and analogues (11 enantiomeric pairs) were separated using an immobilized tyrosine-specific L-RNA aptamer as CSP and an aqueous buffer (8 mM Tris-HCl buffer, 25 mM NaCl, 5 mM MgCl2; pH 7.4) as mobile phase, at a column temperature of 10 degrees C. It appeared that the carboxylic and amino groups as well as the aromatic side chain of amino acid controlled the stereospecific recognition. Modifications on the polar groups were strongly detrimental for enantioselectivity while the replacement of the phenolic group by some bicyclic aromatic residues of different polarity, size or shape did not impair the enantioselective interaction. In addition, the effects of the mobile phase composition and column temperature upon the retention and stereoselective properties of the CSP were assessed. Finally, it was found that the immobilized RNA aptamer could be used under hydro-organic mobile phase conditions without alteration of the stationary phase stability.  相似文献   

15.
A method is reported for the ion-interaction, reversed-phase separation of 24 compounds (chiefly monoamines) arising from the metabolism of tyrosine and tryptophan. These compounds were separated as two groups. The first group comprised 3,4-dihydroxyphenylethylene glycol, tyrosine, 3-methoxy-4-hydroxyphenyl glycol, 5-hydroxytryptophan, norepinephrine, 3,4-dihydroxyphenylacetic acid, epinephrine, 5-hydroxyindole-3-acetic acid, homovanillic acid, 5-hydroxytryptophol, dopamine, tryptophan. N-acetylserotonin, N-acetyltryptophan, 5-methoxytryptophan and serotonin. The mobile phase consisted of a 6.8:93.2 (v/v) mixture of acetonitrile and an aqueous solution containing 0.16 M ammonium phosphate, 0.06 M citric acid, 0.15 mM disodium EDTA, 10 mM dibutylamine and 6 mM sodium 1-octanesulphonate at pH 4.50. The second group of compounds comprised 6-hydroxymelatonin, 5-methoxyindole-3-acetic acid, indole-3-acetic acid, 5-methoxytryptamine, tryptamine, 5-methoxytryptophol, melatonin and tryptophol. The mobile phase consisted of a 16:84 (v/v) mixture of acetonitrile and an aqueous solution containing 0.05 M ammonium phosphate, 0.05 M citric acid, 0.15 mM disodium EDTA, 25 mM dibutylamine and 5 mM sodium 1-octanesulphonate at pH 5.30. Detection was by fluorescence measurement (lambda ex = 280 nm, lambda em = 340 nm). The proposed method exhibited linear calibration over the biochemically significant concentration range, with detection limits in the 10-200 pg range. Excellent precision for peak areas and retention times was observed, even over a period of 24 h. The applicability of amperometric detection (at 0.72V) is also demonstrated. The method is applied to the determination of monoamines in individual rat pineals. Low nanogram levels of tyrosine, norepinephrine, 5-hydroxyindole-3-acetic acid, tryptophan, serotonin and 6-hydroxymelatonin, and picogram levels of 5-hydroxytryptophan, 5-hydroxytryptophol, 5-methoxyindole-3-acetic acid, indole 3-acetic acid, 5-methoxytryptophol and melatonin were indicated in most of the samples.  相似文献   

16.
Huang HY  Chiu CW  Huang IY  Yeh JM 《Electrophoresis》2004,25(18-19):3237-3246
Five common food preservatives were analyzed by capillary electrochromatography, utilizing a methacrylate ester-based monolithic capillary as separation column. In order to optimize the separation of these preservatives, the effects of the pore size of the polymeric stationary phase, the pH and composition of the mobile phase on separation were examined. For all analytes, it was found that an increase in pore size caused a reduction in retention time. However, separation performances were greatly improved in monolithic columns with smaller pore sizes. The pH of the mobile phase had little influence on separation resolution, but a dramatic effect on the amount of sample that was needed to be electrokinetically injected into the monolithic column. In addition, the retention behaviors of these analytes were strongly influenced by the level of acetonitrile in the mobile phase. An optimal separation of the five preservatives was obtained within 7.0 min with a pH 3.0 mobile phase composed of phosphate buffer and acetonitrile 35:65 v/v. Finally, preservatives in real commercial products, including cold syrup, lotion, wine, and soy sauces, were successfully determined by the methacrylate ester-based polymeric monolithic column under this optimized condition.  相似文献   

17.
The electrochemical behaviors of thiazolidine (tetrahydrothiazole) on gold and platinum electrodes were investigated in a Britton-Robinson buffer (pH 2.77-11.61), acetate buffer (pH 4.31), phosphate buffer solutions (pH 2.11 and 6.38) and methanol or acetonitrile containing various supporting electrolytes. Detection was based on a gold wire electrochemical signal obtained with a supporting electrolyte containing 20% methanol-1.0 mM of phosphate buffer (pH 6.87, potassium dihydrogen phosphate and dipotassium hydrogen phosphate) as the mobile phase. Comparison with results obtained with a commercial amperometric detector shows good agreement. Using the chronoamperometric sensor with the current at a constant potential, and measurements with suitable experimental parameters, a linear concentration from 0.05 to 16 mg L-1 was found. The limit of quantification (LOQ) of the method for thiazolidine was found to be 1 ng.  相似文献   

18.
A simple and rapid method based on micro‐liquid chromatography using a synthetic monolithic capillary column was developed for determination of iohexol in human serums, a marker to evaluate the glomerular filtration rate. A hydrophilic methacrylic acid‐ethylene dimethacrylate monolith provided excellent selectivity and efficiency for iohexol with separation time of 3 min using a mobile phase of 40:60 v/v 50 mM phosphate buffer pH 5/methanol. Four serum protein removal, methods using perchloric acid, 50% acetonitrile, 0.1 M zinc sulfate, and centrifuge membrane filter were examined. The method of zinc sulfate was chosen due to its simplicity, compatibility with the mobile phase system, nontoxicity, and low cost. Interday calibration curves were conducted over iohexol concentrations range of 2–500 mg/L (R2 = 0.9997 ± 0.0001) with detection limit of 0.44 mg/L. Intra‐ and interday precisions for peak area and retention time were less than 2.8 and 1.4%, respectively. The method was successfully applied to serum samples with percent recoveries from 102 to 104. The method was applied to monitor released iohexol from healthy subject. Compared with the commercially available reversed‐phase high‐performance liquid chromatography method, the presented method provided simpler chromatogram, faster separation with higher separation efficiency and much lower sample and solvent consumption.  相似文献   

19.
A single enzyme treatment with alpha-amylase, prior to the quantification of added folic acid (FA) in fortified instant fried Asian noodles with analysis performed by capillary zone electrophoresis (CZE) and reversed-phase high performance liquid chromatography (RP-HPLC) with UV detection, is described. The method was validated and optimized for capillary electrophoresis (CE) with separation achieved using a 8 mM phosphate-12 mM borate run buffer with 5% MeOH at pH 9.5. FA was well separated from matrix components with nicotinic acid (NA) employed as an internal standard. In a comparative study, separation of FA was performed using HPLC with a mobile phase consisting of 27% MeOH (v/v) in aqueous potassium phosphate buffer (3.5 mM KH(2)PO(4) and 3.2 mM K(2)HPO(4)), pH 8.5, and containing 5 mM tetrabutylammonium dihydrogen phosphate as an ion-pairing agent. For both methods, excellent results were obtained for various analytical parameters including linearity, accuracy and precision. The limit of detection was calculated to be 2.2 mg/L for CE without sample stacking and 0.10 mg/L with high performance liquid chromatography (HPLC). Sample extraction involved homogenization and enzymatic extraction with alpha-amylase. Results indicated that FA was stable during four main stages of instant fried noodle manufacturing (dough crumbs, cut sheets, steaming and frying).  相似文献   

20.
An isocratic high-performance liquid chromatographic method for separation and determination of phenolphthalein and its metabolite, phenolphthalein-glucuronide, using bromocresol purple as an internal standard is described. The method uses a mobile phase of 50 mM phosphate buffer (pH 7.7)-methanol (52.5:47.5, v/v), a 3-μm reversed-phase C18 column (50 × 4.6-mm i.d.), a flow rate of 1 ml/min, and UV detector wavelength of 230 nm. The most important variables that can affect the retention of these compounds (i.e., organic modifier concentration, buffer concentration, and pH) were systematically studied. Two different retention orders were observed, depending on buffer concentration and pH. The effects on retention of the addition of triethylamine or acetic acid to the mobile phase are also discussed. This method has been developed for future application to the determination of phenolphthalein and phenolphthalein-glucuronide in biological fluids such as plasma, bile, and urine of rats within a study involving a new model for enterohepatic recirculation and pharmacokinetics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号