1.
A rotating phantom for the study of flow effects in MR imaging   总被引:2,自引:0,他引:2  
A common type of phantom used for the study of flow effects in MR imaging is the tube phantom, where a liquid passes through a set of tubes placed in the main magnetic field of an MR scanner. Among the disadvantages with this type of phantom are that a distribution of velocities is present in each tube, and that quantifications of flow effects using tube phantoms may be very time-consuming. In this work, we describe the design and the properties of a rotating wheel flow phantom used for quantification of the effects of flow through the imaging plane as well as in the imaging plane. The proposed phantom is constructed as a rotating gel-filled wheel, surrounded by static volumes filled with the same gel, and the evaluation of the information from rotating and static parts is made with a specially designed computer program. The phantom can be used as a plug flow phantom covering simultaneously an interchangeable velocity interval, which at present has the range −52 mm/s, +52 mm/s. It is shown that the phantom gives adequate information on the dependence of pixel content on first-order motion in MR modulus and phase images. Among the fields of application are rapid calibration of MR imaging units for flow determination using phase information, as well as testing of pulse sequence characteristics and verification of theoretical predictions concerning the flow dependence in MR images.  相似文献   

2.
Flow-sensitive experiments (FAIR) have been performed on a tube-flow phantom in order to validate quantitative perfusion measurements on humans. A straight-forward correspondence between perfusion and bulk-flow is found. It is shown that the flow phantom model only holds when the slice profiles of the involved RF pulses are taken into account. A small flow-independent off-set may be present in the data. The off-set is explained by the model. Based on the correspondence between the phantom and the in vivo models, it is shown that the lowest flow values that could be measured in the phantom correspond to perfusion values lower than the cortical perfusion in the brain. Thus, the experimental accuracy and the computational methods for quantitative perfusion measurements in vivo can be validated by a tube-flow phantom.  相似文献   

3.
《Magnetic resonance imaging》1998,16(9):1043-1048
We used a cranial phantom to investigate how intracranial mechanical factors [brain compliance and the resistance to the flow of cerebrospinal fluid (CSF)] affect the way in which CSF pulsations are driven by pulsatile transcranial blood flow. Dynamic phase-contrast magnetic resonance imaging (MRI) was used to measure the transfer function between vascular pulsations and pulsatile response of the CSF below the foramen magnum of the phantom. We found that the coupling between the high frequency components of cervical CSF flow and transcranial blood flow was decreased when the phantom was modified to simulate increased brain compliance and increased resistance to CSF flow.  相似文献   

4.
Blood oxygenation and flow are both important parameters in a living body. In this Letter, we introduce a simple configuration to simultaneously measure blood flow and oxygenation using an off-the-shelf spectrometer. With the integration time of 10 ms, flow phantom measurements, a liquid blood phantom test, and an arm cuff occlusion paradigm were performed to validate the feasibility of the system. We expect this proof-of-concept study would be widely adopted by other researchers for acquiring both blood flow and oxygenation changes due to its straightforward configuration and the possibility of multimodal measurement.  相似文献   

5.
超声动态向量血流成像的产品化实现   总被引:1,自引:1,他引:0  
传统超声彩色多普勒成像测量的是血流沿超声传播方向上的速度分量,故无法得到垂直于超声传播方向的血流。向量血流成像是一种更加先进的超声血流成像技术。它不受角度限制,可以直接计算出血流速度的大小和方向。本文总结了现有多种超声向量血流成像技术的特点和发展情况,并从产品化实现的角度分析了各项技术的优缺点。从超声系统发射接收、血流成像、向量速度方向合成、显示等几个方面详述了迈瑞超声向量血流成像技术产品化实现过程中遇到的主要问题及解决方案。实验采用了中科院声学所研制的超声多普勒仿血流体模,通过向量血流成像和脉冲多普勒成像分别测量体模的仿血流速度。将向量血流成像直接计算出来的速度值与脉冲多普勒经过角度校正得到的速度进行对比。在不同条件下,经过多次测量,二者的平均相对误差均在10%以内。  相似文献   

6.
In this Letter,we examine the phantom energy accretion onto a Kehagias-Sfetsos black hole in Horava-Lifshitz gravity.To discuss the accretion process onto the black hole,the equations of phantom flow near the black hole have been derived.It is found that mass of the black hole decreases because of phantom accretion.We discuss the conditions for critical accretion.Graphically,it has been found that the critical accretion phenomena is possible for different values of parameters.The results for the Schwarzschild black hole can be recovered in the limiting case.  相似文献   

7.

Introduction

To clarify the mechanism underlying apparent diffusion coefficient (ADC) changes in regional intracranial tissue during the cardiac cycle, we investigated relationships among ADC changes, volume loading, and intracranial pressure using a hemodialyzer phantom in magnetic resonance imaging (MRI).

Materials and Methods

The hemodialyzer phantom consisted of hollow fibers (HF), the external space of HFs (ES), and a gateway of dialysis solution, filled with syrup solution and air. The high-volume and low-volume loadings were periodically applied to HFs by a to-and-fro flow pump, and syrup solution was permitted to enter or leave HFs during the volume loading cycles. ADC maps at each volume loading phase were obtained using ECG-triggered single-shot diffusion echo-planar imaging. Dynamic phase contrast MRI was also used to measure volume loading to the phantom. We compared the ADC changes, volume loading, and intracranial pressure in the phantom during the cardiac cycle.

Results

ADC changes synchronized significantly with absolute volumetric flow rate change. The maximum ADC change was higher in high-volume loading cycles than in low-volume loading cycles. Results showed that the water molecules in ES fluctuated according to the force transferred from HF to ES. ADC changes were dependent upon the volumetric flow rate during the cardiac cycle.

Conclusions

Our original phantom allowed us to clarify the mechanism underlying water fluctuations in intracranial tissues. Measurement of maximum changes in ADC is an effective method to define the transfer characteristics of the arterial pulsatile force in regional intracranial tissue.  相似文献   

8.
We propose an approach for absolute velocity measurement where the use of a beam displacer provides two orthogonal linearly polarized beams to probe the sample simultaneously at two different incidence angles. The approach helps remove the cross talk image and facilitates single detector-based Fourier domain Doppler velocity measurement. The system has been characterized by quantifying absolute flow velocity in a flow phantom.  相似文献   

9.
Color Doppler optical coherence tomography (CDOCT) is a noninvasive optical imaging technique for micrometer-scale physiological flow mapping simultaneously with morphological optical coherence tomography imaging. We have developed a novel CDOCT signal-processing strategy capable of imaging physiological flow rates at 8 frames/s. Our new strategy features hardware-implemented digital autocorrelation across subsequent scans, permitting us to measure 300-Hz-8-kHz Doppler shifts upon signals of 0.6-MHz bandwidth. The performance of the CDOCT system was demonstrated in a flow phantom and in vivo in Xenopus laevis.  相似文献   

10.
In this paper, a method of three-dimensional (3D) vessel localization is presented to allow the identification of a vessel of interest, the selection of a vessel segment, and the determination of a slice orientation to improve the accuracy of phase-contrast magnetic resonance (PCMR) angiography. A marching-cube surface-rendering algorithm was used to reconstruct the 3D vasculature. Surface-rendering was obtained using an iso-surface value determined from a maximum intensity projection (MIP) image. This 3D vasculature was used to find a vessel of interest, select a vessel segment, and to determine the slice orientation perpendicular to the vessel axis. Volumetric flow rate (VFR) was obtained in a phantom model and in vivo using 3D localization with double oblique cine PCMR scanning. PCMR flow measurements in the phantom showed 5. 2% maximum error and a standard deviation of 9 mL/min during steady flow, 7.9% maximum error and a standard deviation of 13 mL/min during pulsatile flow compared with measurements using an ultrasonic transit-time flowmeter. PCMR VFR measurement error increased with misalignment at 10, 20, and 30 degrees oblique to the perpendicular slice in vitro and in vivo. The 3D localization technique allowed precise localization of the vessel of interest and optimal placement of the slice orientation for minimum error in flow measurements.  相似文献   

11.
Phase contrast techniques in combination with k-space segmented CINE imaging are widely used for the quantitative assessment of blood flow or tissue motion. The temporal resolution of the corresponding pulse sequences plays an important role concerning the potential of the method to fully detect time resolved flow or motion patterns. A further improvement of temporal or spatial resolution in phase contrast CINE MRI can be achieved by the application of view sharing. Based on simulations with point-spread-functions resulting from different cyclic flow or motion patterns an analysis of view sharing techniques in combination with phase contrast MRI is presented. Velocity mapping properties and the role of different k-space regions concerning the resulting values in the phase images and thus encoded velocities were investigated. It could be shown that the velocity induced phase shifts in phase contrast techniques are mainly encoded in the central sections of k-space which makes view sharing also suitable for velocity mapping. As a result the use of appropriate sampling and data acquisition schemes permits the assessment of flow or motion patterns with significantly improved temporal resolution without loss of functional information. In addition phantom measurements with an oscillation phantom were performed in order to validate the simulation results and to demonstrate the potential of view sharing techniques to accelerate phase contrast imaging and improve the detection of the underlying flow or motion dynamics.  相似文献   

12.
黄孝龙  李宁  翁春生  康杨 《中国物理 B》2022,31(1):14703-014703
Instantaneous and precise velocity sensing is a critical part of research on detonation mechanism and flow evolution.This paper presents a novel multi-projection tunable diode laser absorption spectroscopy solution,to provide a real-time and reliable measurement of velocity distribution in detonation exhaust flow with obvious nonuniformity.Relations are established between overlapped spectrums along probing beams and Gauss velocity distribution phantom according to the frequency shifts and tiny variations in components of light-of-sight absorbance profiles at low frequencies analyzed by the fast Fourier transform.With simulated optical measurement using H2O feature at 7185.6 cm-1 carried out on a phantom generated using a simulation of two-phase detonation by a two-fluid model,this method demonstrates a satisfying performance on recovery of velocity distribution profiles in supersonic flow even with a noise equivalent absorbance up to 2×10-3.This method is applied to the analysis of rapidly decreasing velocity during a complete working cycle in the external flow field of an air-gasoline detonation tube operating at 25 Hz,and results show the velocity in the core flow field would be much larger than the arithmetic average from traditional tunable diode laser doppler velocimetry.This proposed velocity distribution sensor would reconstruct nonuniform velocity distribution of high-speed flow in low cost and simple operations,which broadens the possibility for applications in research on the formation and propagation of external flow filed of detonation tube.  相似文献   

13.
Luo Z  Wang Z  Yuan Z  Du C  Pan Y 《Optics letters》2008,33(10):1156-1158
A dual-imaging modality is demonstrated for high-resolution quantitative imaging of local cerebral blood flow in the rat cortex by combining simultaneous spectral-domain Doppler optical coherence tomography (SDOCT) and full-field laser speckle contrast imaging (LSCI). Preliminary studies in tissue flow phantom and cocaine-induced cerebral blood flow changes indicated that by correlating coregistered cortical arterial blood flow, the relative measurement of flow changes by LSCI could be accurately calibrated by the absolute flow imaging provided by SDOCT (least square fit, r(2) approximately 0.96). Quantitative LSCI of cerebral blood flow is crucial to the quantitative analyses of the spatiotemporal hemodynamics of functional brain activations and thus improved understanding of neural process.  相似文献   

14.
An optical Doppler tomography (ODT) system that permits imaging of fluid flow velocity in highly scattering media is described. ODT combines Doppler velocimetry with the high spatial resolution of low-coherence optical interferometry to measure fluid flow velocity at discrete spatial locations. Tomographic imaging of particle flow velocity within a circular conduit submerged 1 mm below the surface in a highly scattering phantom of Intralipid is demonstrated.  相似文献   

15.
Wang RK 《Optics letters》2008,33(16):1878-1880
An effective digital frequency modulation approach to achieve directional blood flow imaging within microcirculations in tissue beds in vivo for optical microangiography is presented. The method only requires the system to capture one three-dimensional data set within which the interferograms are modulated by a constant frequency modulation that gives one directional flow information. The result is that the imaging speed is doubled and the computational load is halved. The method is experimentally validated by a flow phantom and is tested for imaging of cerebral vascular blood perfusion in a live mouse with the cranium left intact.  相似文献   

16.
Mohan N  Vakoc B 《Optics letters》2011,36(11):2068-2070
The intensity signal in optical coherence tomography contains information about the translational velocity of scatterers, and can be used to quantify blood flow. We apply principal component analysis to efficiently extract this information. We also study use of nonuniform temporal sampling of the intensity signal to increase the range of quantifiable flow velocities. We demonstrate this technique in simulation, phantom and in vivo blood flow measurements, and highlight its potential to enable three-dimensional wide-field mapping of blood flow using OCT.  相似文献   

17.
Chen SL  Xie Z  Carson PL  Wang X  Guo LJ 《Optics letters》2011,36(20):4017-4019
We recently proposed photoacoustic correlation spectroscopy (PACS) and demonstrated a proof-of-concept experiment. Here we use the technique for in vivo flow speed measurement in capillaries in a chick embryo model. The photoacoustic microscopy system is used to render high spatial resolution and high sensitivity, enabling sufficient signals from single red blood cells. The probe beam size is calibrated by a blood-mimicking phantom. The results indicate the feasibility of using PACS to study flow speeds in capillaries.  相似文献   

18.
Self-referenced Doppler optical coherence tomography   总被引:1,自引:0,他引:1  
Yazdanfar S  Izatt JA 《Optics letters》2002,27(23):2085-2087
Doppler optical coherence tomography (DOCT) allows simultaneous micrometer-scale resolution cross-sectional imaging of tissue structure and blood flow. We demonstrate a fiber-optic polarization-diversity-based differential phase contrast DOCT system as a method to perform self-referenced velocimetry in highly scattering media. Using this strategy, we reduced common-mode interferometer noise to <1 Hz and improved Doppler estimates in a scattering flow phantom by a factor of 5.  相似文献   

19.
Diffusion of spins between physical or virtual, communicating compartments having different states of longitudinal magnetization leads to diffusion-driven longitudinal relaxation. Herein, in two model systems, the effects of diffusion-driven longitudinal relaxation are explored experimentally and analyzed quantitatively. In the first case, longitudinal relaxation in a single slice of a water phantom is monitored spectroscopically as a function of slice thickness. In the second case, mimicking vascular flow/diffusion effects, longitudinal relaxation is monitored in a two-compartment, semi-permeable fiber phantom. In both cases, apparent longitudinal relaxation, though clearly multi-exponential, is well-modeled as bi-exponential.  相似文献   

20.
In atherosclerotic inducement in animal models, the conventionally used balloon injury is invasive, produces excessive vessel injuries at unpredictable locations and is inconvenient in arterioles. Fortunately, cavitation erosion, which plays an important role in therapeutic ultrasound in blood vessels, has the potential to induce atherosclerosis noninvasively at predictable sites. In this study, precise spatial control of cavitation erosion for superficial lesions in a vessel phantom was realised by using an ultrasonic standing wave (USW) with the participation of cavitation nuclei and medium-intensity ultrasound pulses. The superficial vessel erosions were restricted between adjacent pressure nodes, which were 0.87 mm apart in the USW field of 1 MHz. The erosion positions could be shifted along the vessel by nodal modulation under a submillimetre-scale accuracy without moving the ultrasound transducers. Moreover, the cavitation erosion of the proximal or distal wall could be determined by the types of cavitation nuclei and their corresponding cavitation pulses, i.e., phase-change microbubbles with cavitation pulses of 5 MHz and SonoVue microbubbles with cavitation pulses of 1 MHz. Effects of acoustic parameters of the cavitation pulses on the cavitation erosions were investigated. The flow conditions in the experiments were considered and discussed. Compared to only using travelling waves, the proposed method in this paper improves the controllability of the cavitation erosion and reduces the erosion depth, providing a more suitable approach for vessel endothelial injury while avoiding haemorrhage.  相似文献   