首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
In this paper we present the design of a modified hexagonal photonic crystal fiber (PCF) having high birefringence and a near-zero flattened dispersion. Using the finite-difference method (FDM), it is shown that the proposed multiple Gedoped core hexagonal PCF exhibits a high birefringence of order 10−3 and a nearly zero flattened dispersion in the optical coherence tomography (OCT) waveband. In addition, the proposed PCF has a confinement loss of less than 10−8 dB/m at 1.06 μm. PCFs with such properties are considered suitable for both endoscopic OCT and other experimental setups employing 1.06 μm lasers.  相似文献   

2.
In this paper, we propose a highly nonlinear dispersion flattened hexagonal photonic crystal fiber (HNDF-HPCF) with nonlinear coefficients as large as 57.5W−1 km−1 at 1.31 μm wavelength for dental optical coherence tomography (OCT) applications. This HNDF-HPCF offers not only large nonlinear coefficient but also very flat dispersion slope and very low confinement losses. Using these characteristics of our proposed PCF, it is shown through simulations by using finite difference method with an anisotropic perfectly matched boundary layer that this PCF offers the efficient supercontinuum (SC) generation for dental OCT applications at 1.31 μm wavelength using a picosecond pulse easily produced by commercially available less expensive laser sources. Coherent length of light source using SC is found 10 μm and the spatial resolutions in the depth direction for dental applications of OCT are found about 6.1 μm for enamel and 6.5 μm for dentin.  相似文献   

3.
A lensed patch cord probe has been made with a ball lens packaged in a metal cylinder. By simply placing a ball lens directly in front of a fiber patch cord, a compact and potentially disposable sampling probe for optical coherence tomography (OCT) could be implemented. To achieve a sufficiently long working distance and a good transverse resolution simultaneously, the proper ball lens diameter and the distance between the ball lens and the fiber patch cord were investigated. Experimentally, a working distance of up to 5.2 mm, 3 dB bandwidth of 2 mm, and transverse resolution of 16 μm were achieved. With the patch cord probe, a common path swept source OCT system was implemented and used to demonstrate the feasibility as the dedicated probe for dentistry.  相似文献   

4.
Spectral response of acoustically induced microbending through thin optical fiber is discussed from mode-coupling of core and cladding modes. The thin fiber is analyzed in three-layered structure (core-cladding-air) to gain insights into acousto-optic modulation. We explained the dependence of core and/or cladding diameters on acoustic source parameters from numerical calculations. According to the calculations, we successfully fabricated all-optical tunable filter using this thin fiber that yields an efficient mode-coupling at flexural wave frequencies less than 1MHz. To increase the acousto-optic effect, we used a specially designed thin optical fiber (80 μm of cladding diameter) in the section where flexural wave is produced, and spliced both ends of the thin fiber to the tapered 125 μm fibers. The frequency and voltage tuning of fabricated filter is also confirmed by changing the driven frequency and applied voltage of the PZT, respectively. This result suggests a possibility of fiber-optic device application as all-optical tunable filter at 1.55 μm.  相似文献   

5.
Ullah  H.  Davoudi  B.  Mariampillai  A.  Hussain  G.  Ikram  M.  Vitkin  I. A. 《Laser Physics》2012,22(4):797-804
The increase of glucose levels in blood changes the viscosity of flowing fluids and shape of the erythrocytes. Both of these can affect the details of light scattering as can be quantified via decorrelation times measured by optical coherence tomography (OCT). The relative contributions of these competing effects have been studied by examining the motion dynamics of deformable asymmetrical (red blood cells, RBCs with ∼7 μm diameter and ∼2 μm thickness) and non deformable symmetrical (polystyrene microspheres, PSM with 1.4 μm diameter) flowing scattering particles. The fluid flow under the action of gravity was modulated by changing the glucose concentrations. Quantitative analysis of the OCT’s M-mode autocorrelation functions enabled the derivations of the translational diffusion coefficients. These systematic studies are aimed at eventual tissue imaging scenarios with speckle-variance OCT to obtain local glucose concentrations maps.  相似文献   

6.
We design a multi-layer cladding large-core planar waveguide that supports a single guided mode. The waveguide works on the principle of higher-order mode discrimination. The cladding of the waveguide is formed by alternate low- and high- index regions, which helps leaking out of higher-order modes while retaining the fundamental mode over the entire length of the waveguide. The structure is analyzed by the transfer-matrix method and the leakage losses of the modes have been calculated. We show that a waveguide formed in silica with numerical aperture 0.24 and core width 10 μm can be designed to exhibit single-mode operation at 1550-nm wavelength. Such a structure should find applications in high-power planar waveguide lasers and amplifiers.  相似文献   

7.
Xi J  Chen Y  Zhang Y  Murari K  Li MJ  Li X 《Optics letters》2012,37(3):362-364
We report an all-fiber-optic scanning, multimodal endomicroscope capable of simultaneous optical coherence tomography (OCT) and two-photon fluorescence (TPF) imaging. Both imaging modalities share the same miniature fiber-optic scanning endomicroscope, which consists of a double-clad fiber with a core operating in single mode at both the OCT (1310 nm) and two-photon excitation (1550 nm) wavelengths, a piezoelectric two-dimensional fiber-optic beam scanner, and a miniature aspherical compound lens suitable for simultaneous acquisition of en face OCT and TPF images. A fiber-optic wavelength division multiplexer was employed in the integrated platform to combine the low coherence OCT light source and the femtosecond two-photon excitation laser into the same optical path. Preliminary imaging results of cell cultures and mouse tissue ex vivo demonstrate the feasibility of simultaneous real-time OCT and TPF imaging in a scanning endomicroscopy setting for the first time.  相似文献   

8.
In this paper, we report the design of a highly nonlinear dispersion flattened high-index-core square photonic crystal fiber (PCF) for applications in optical coherence tomography (OCT). The finite-difference method with an anisotropic perfectly matched boundary layer is used as a numerical simulation tool. A set of optimized design parameters numerically resulted in a nonlinear coefficient of 79.9W−1 km−1 and a dispersion of −0:186 ps/(nm·km) at a wavelength of approximately 1.06 μm. Owing to its high nonlinear coefficient and flattened dispersion, the PCF is expected to be suitable for broadband supercontinuum generation, which is considered very important in OCT medical applications.  相似文献   

9.
严雪过  沈毅  潘聪  李鹏  丁志华 《物理学报》2016,65(2):24201-024201
本文报道了一种基于拉锥结构的全光纤型内窥光学相干层析成像探针. 基于大纤芯多模光纤的低光束发散特性, 使用大纤芯多模光纤代替透镜作为成像元件, 并在单模光纤与大纤芯多模光纤之间引入过渡拉锥段以减少插入损耗. 首先利用光学仿真软件(Rsoft)确定探针的最佳结构, 然后通过拉锥、切割以及熔接工艺实现探针制作, 并对探针的出射光束特性与插入损耗进行测量, 最后将该探针与扫频光学相干层析成像主系统联机, 对人体指尖皮肤及鸡气管壁组织进行成像. 该探针直径为250 μm, 不锈钢保护管外径为325 μm, 硬端长度1 cm, 插入损耗约为0.3 dB, 空气中有效成像范围达800 μm. 该探针为内窥光学相干层析成像技术在心血管疾病的应用提供了高紧凑度、高传输效率与高灵活性的选择.  相似文献   

10.
A needle-fiber optical coherence tomography (OCT) system designed for guiding epidural anesthesia to a target is presented. In the preliminary experiment, a desired target in tofu as a strong scattering medium can be monitored over a sufficient range of several millimeters within a short measuring time. The axial resolution is 21 μm. In order to investigate the ranging performance, the relation between background noise levels and focus-scattering properties in a confocal optical system is numerically studied by use of Monte Carlo technique. Numerical results indicate that an appropriate focal length of the lens attached to the fiber should be used to separate the OCT signal from strong noise in strongly scattered medium.  相似文献   

11.
We have applied a compact low power rapid scanning Doppler Optical Coherence Tomography system to monitor multi-dimensional velocity profiles within the complex vessels and simultaneous real-time non-invasive imaging of skin tissues morphology in vivo, in the wavelength range of 1.3–1.5 nm. Optical clearing of skin tissues has been utilized to achieve depth of OCT images up to 1.7 mm. Current approach enables applying low-power (0.4–0.5 mW) and low-noise broadband near-infrared light sources and obtaining OCT images with down to 12 μm spatial resolution. Two-dimensional time-domain OCT images of complex flow velocity profiles in blood vessel phantom and in vivo subcutaneous human skin tissues are presented. The effect of optical clearing on in vivo images is demonstrated and discussed.  相似文献   

12.
Tsai  M. -T.  Chang  F. -Y. 《Laser Physics》2012,22(4):791-796
In this study, a swept-source optical coherence tomography (SS-OCT) system with a Fourier domain mode locking (FDML) laser is proposed for a dermatology study. The homemade FDML laser is one kind of frequency-sweeping light source, which can provide output power of >20 mW and an output spectrum of 65 nm in bandwidth centered at 1300 nm, enabling imaging with an axial resolution of 12 μm in the OCT system. To eliminate the forward scans from the laser output and insert the delayed backward scans, a Mach-Zehnder configuration is implemented. Compared with conventional frequency-sweeping light sources, the FDML laser can achieve much higher scan rates, as high as ∼240 kHz, which can provide a three-dimensional imaging rate of 4 volumes/s. Furthermore, the proposed high-speed SS-OCT system can provide three-dimensional (3D) images with reduced motion artifacts. Finally, a high-speed SS-OCT system is used to visualize hair follicles, demonstrating the potential of this technology as a tool for noninvasive diagnosis of alopecia.  相似文献   

13.
A novel kind of single-mode large-mode-area optical fiber is presented in this paper. The proposed fiber core is composed of high-index central rod and the surrounding multilayer rings. The mode characteristics are discussed considering the fiber structure parameters. The calculation results show that the proposed fiber possesses extreme large mode area of 2975 μm2 with single mode operation at the wavelength of 1.08 μm. Even larger mode area of the complex ring core fiber with single mode output can be achieved by coiling the fiber, due to the significant difference of bending loss between the fundamental mode and the higher-order transverse modes. Such fibers are expected to find applications in the field of fiber lasers and amplifiers.  相似文献   

14.
Fiber optic displacement sensors with bundled and fused coupler fiber probes are being investigated. The effects of axial displacements on the detected output voltages are also investigated for fiber bundle probe sensor. The resolutions obtained are 0.9 and 4.0 μm, for the front and back slopes, respectively. A comparison is made with a commercial plastic based multimode fused coupler which gives a better range of 2.0 mm. This is longer than that achieved by the fiber bundle probe which is only 0.4 mm and has a lower resolution of 34 μm for the case of 50:50 coupling ratio.  相似文献   

15.
High near-infrared transparency Tm3+-doped germanate bulk glass and fiber have been fabricated and 2 μm emission properties demonstrated. Energy-transfer processes in the germanate glass and fiber are discussed. The emission spectra are obtained from both bulk glass and fiber with the excitation of a 794 nm laser diode. The results indicate that the line width of the Tm3+:3F43H6 emission spectra measured in fibers is narrower than that of the bulk glass sample and shifts to longer wavelengths with increment of fiber length. The extended overlap integral method is used to calculate the microparameters of energy transfer and critical distance. A model is derived to better understand of the energy-transfer process of thulium ions in the germanate glasses responsible for emission at 2 μm. The study indicates that Tm3+-doped germanate fibers with a large core diameter has proved to be promising infrared optical and high-power level laser materials.  相似文献   

16.
A dynamical model of oxide-confined Vertical-Cavity Surface-Emitting Lasers (VCSELs) with two-dimensional photonic crystals (PCs) incorporated within them so called PC-VCSELs is presented and used to optimise designs for high-power single-mode operation. Three PC-VCSEL designs are considered: (I) with holes in the top DBRs, (II) with PC holes situated between their DBRs and (III) with PC holes etched through the entire VCSEL. A simulated design for a PC-VCSEL of type (I) with holes of d = 2 μm diameter, a = 4 μm lattice constant (d/a = 0.5) and 2.2 μm depth was found to improve the single mode behaviour but not enough to establish single mode behaviour for large apertures. The modulation behaviour was not degraded by the PC. Simulations of type (II) and (III) PC-VCSELs, with the same parameters, have shown multimode operation and degraded modulation properties. Simulations of PC-VCSELs of type (III) with holes of d = 0.2 μm diameter and a = 0.4 μm lattice constant (d/a = 0.5) have shown improved modulation properties and enhanced single mode power for small apertures. In simulation, PC-VCSELs incorporating multiple PC-defects have shown order of magnitude increases in the single mode output power. However, the modulation properties of these VCSELs show degradation due to gain saturation and hopping of the optical modes localized within the PC defects.  相似文献   

17.
This paper presents a highly nonlinear octagonal photonic crystal fiber (HN-OPCF) with a Ge-doped core for dental optical coherence tomography (OCT) applications. The simulation results show that a nonlinear coefficient of 56.3W−1 km−1 and the flattened dispersion of less than −1:0 ps/(nm·km) are obtained in 75 nm waveband (1265–1340 nm). Owing to its high nonlinear coefficient and flattened dispersion, the HN-OPCF is expected to be suitable for supercontinuum generation, which is very important in OCT applications. The numerical simulation results demonstrate that the proposed HN-OPCF can generate wideband supercontinuum.  相似文献   

18.
Real-time, ultrahigh-resolution optical coherence tomography (OCT) is demonstrated in the 1.4-1.7-microm wavelength region with a stretched-pulse, passively mode-locked, Er-doped fiber laser and highly nonlinear fiber. The fiber laser generates 100-mW, linearly chirped pulses at a 51-MHz repetition rate. The pulses are compressed and then coupled into a normally dispersive highly nonlinear fiber to generate a low-noise supercontinuum with a 180-nm FWHM bandwidth and 38 mW of output power. This light source is stable, compact, and broadband, permitting high-speed, real-time, high-resolution OCT imaging. In vivo high-speed OCT imaging of human skin with approximately 5.5-microm resolution and 99-dB sensitivity is demonstrated.  相似文献   

19.
We demonstrate ultrahigh-resolution optical coherence tomography (OCT) using continuum generation in an air-silica microstructure fiber as a low-coherence light source. A broadband OCT system was developed and imaging was performed with a bandwidth of 370 nm at a 1.3-mu;m center wavelength. Longitudinal resolutions of 2.5 microm in air and ~2 microm in tissue were achieved. Ultrahigh-resolution imaging in biological tissue in vivo was demonstrated.  相似文献   

20.
The spectral excess attenuation caused by coupling between the guided HE11 mode and radiation modes is calculated with the aid of the formula derived by Marcuse for the radiation loss of a monomode optical fiber with step-index profile and sinusoidally perturbed core radius. The pronounced minima and maxima of the spectral excess attenuation curve converge as the spatial frequency of the perturbation of the core radius increases. Even perturbation amplitudes as small as 0.01 μm may lead to excess attenuations of the order of 10 dB/km if the radiation wavelength does not coincide with an attenuation minimum. The spectral behavior of the excess attenuation can be utilized to design fibers which act as optical filters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号