首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
In this study, dynamics of nanoparticles penetrating and accumulating in biotissue (healthy skin) was investigated in vivo by the noninvasive method of optical coherence tomography (OCT). Gold nanoshells and titanium dioxide nanoparticles were studied. The processes of the nanoparticles penetration and accumulation in biotissue are accompanied by the changes in optical properties of skin which affect the OCT images. The continuous OCT monitoring of the process of the nanoparticles penetration into skin showed that these changes appeared in 30 min after application of nanoparticles on the surface; the time of accumulation of maximal nanoparticles concentration in skin was observed in period of 1.5–3 h after application. Numerical processing of the OCT signal exhibited the increase in contrast between upper and lower parts of dermis and contrast decay of the hair follicle border during 60–150 min. The transmission electron microscopy technique confirmed accumulation of the both types of nanoparticles in biotissue. The novelty of this study is presentation of OCT ability to in vivo monitor dynamics of nanoparticles penetration and their re-distribution within living tissues.  相似文献   

2.
The study of flow dynamics in complex geometry vessels is highly important in various biomedical applications where the knowledge of the mechanic interactions between the moving fluid and the housing media plays a key role for the determination of the parameters of interest, including the effect of blood flow on the possible rupture of atherosclerotic plaques. Doppler Optical Coherence Tomography (DOCT), as a functional extension of Optical Coherence Tomography (OCT), is an optic, non-contact, noninvasive technique able to achieve detailed analysis of the flow/vessel interactions. It allows simultaneous high resolution imaging (∼10 μm typical) of the morphology and composition of the vessel and determination of the flow velocity distribution along the measured cross-section. We applied DOCT system to image high-resolution one-dimensional and multi-dimensional velocity distribution profiles of Newtonian and non-Newtonian fluids flowing in vessels with complex geometry, including Y-shaped and T-shaped vessels, vessels with aneurism, bifurcated vessels with deployed stent and scaffolds. The phantoms were built to mimic typical shapes of human blood vessels, enabling preliminary analysis of the interaction between flow dynamics and the (complex) geometry of the vessels and also to map the related velocity profiles at several inlet volume flow rates. Feasibility studies for quantitative observation of the turbulence of flows arising within the complex geometry vessels are discussed. In addition, DOCT technique was also applied for monitoring cerebral mouse blood flow in vivo. Two-dimensional DOCT images of complex flow velocity profiles in blood vessel phantoms and in vivo sub-cranial mouse blood flow velocities distributions are presented.  相似文献   

3.
The purpose of study is to quantify and compare diffusion of propylene glycol, glucose, glycerol in the human skin in vivo noninvasively. Optical coherence tomography (OCT) was utilized in the functional imaging of optical cleaning agents for monitoring and quantifying the permeability coefficients (PCs) of them. Our experiments showed that the permeability coefficient of 40% propylene glycol from different subjects was averaged and found to be (2.52 ± 0.02) × 10−6 cm/s, the permeability coefficient of 40% glucose was (1.94 ± 0.05) × 10−6 cm/s, and the permeability coefficient of 40% glycerol was (1.82 ± 0.04) × 10−6 cm/s. The results indicated that the diffusion of propylene glycol solutions was faster than that of glucose solution, and the diffusion of glucose solutions was faster than that of glycerol solutions. The dependence of the permeability on the different hyperosmotic analytes could potentially be used in various basic science and clinical fields, such as optical clearing of tissues and cells as well as in clinical pharmacology.  相似文献   

4.
Zhao SY  Yu X  Qiu HX  Huang NY  Wang TS  Xue P  Gu Y 《光谱学与光谱分析》2010,30(12):3347-3350
光学相干层析术(optical coherence tomography,简称OCT)具有非侵入性,高分辨及高速成像的优点,特别适合于生物医学领域。但由于大部分生物组织具高散射系数,通常仅能对表层组织下数毫米深度内进行成像。穿透深度不足限制了OCT在皮肤科等领域应用。作为常见多发病的鲜红斑痣具有病变组织浅,血管增生明显等特点,所以OCT非常适于鲜红斑痣的检测。通过选择皮肤穿透性好的中心波长为1310nm超辐射二极管,合理优化样品臂和参考臂光强比例及偏振控制,实现了对鲜红斑痣在体成像研究,采集了清晰的OCT图像,得到其关键特征参数,如表皮层厚度,血管直径等,对鲜红斑痣的诊断及制定合理治疗方案具有重要意义。  相似文献   

5.
Spatial distribution of superficial blood vessels in human skin in vivo has been observed by using the double correlation Optical Coherence Tomography (OCT). To remove background noise, reduce the artifacts associated with patient motions and to increase the overall quality of the experimental OCT images an adaptive Wiener filtering technique has been employed. Fourier domain correlation has been subsequently applied to enhance spatial resolution of images of vascular network in human skin in vivo. Image processing has been performed on Graphics Processing Units (GPUs) utilizing Compute Unified Device Architecture (CUDA) framework in the frequency‐domain. This approach allows carrying out image processing in parallel significantly speeding up the computations. The presented results show that the double correlation method permits obtaining 2D/3D OCT images of subcutaneous microcirculation vascular network and its spatial distribution within the human skin with higher spatial resolution compare to the other OCT correlation‐based techniques developed earlier.  相似文献   

6.
We have proposed a tested in tissue phantoms and in vivo a novel sensor based on optical coherence tomography (OCT) for noninvasive and continuous monitoring of blood glucose concentration. OCT images were obtained from pig and rabbit skin before and after glucose administration. Slopes of OCT signals decreased substantially (~40% in tissues in vivo) and linearly with the increase of blood glucose concentration from 4 to 30 mM, typical for normal and diabetic subjects. Phantom studies demonstrated 1% accuracy of scattering-coefficient measurement. Our theoretical and experimental studies suggest that glucose concentration can potentially be measured noninvasively with high sensitivity and accuracy with OCT systems.  相似文献   

7.
Xu C  Ye J  Marks DL  Boppart SA 《Optics letters》2004,29(14):1647-1649
Optical coherence tomography (OCT) images of biological tissues often have low contrast. Spectroscopic optical coherence tomography (SOCT) methods have been developed to enhance contrast but remain limited because most tissues are not spectrally active in the frequency bands of laser sources commonly used in OCT. Near-infrared (NIR) dyes with absorption spectra features within the OCT source spectrum can be used for enhancing contrast in this situation. We introduce and demonstrate the use of NIR dyes as contrast agents for SOCT. Contrast-enhanced images are compared with fluorescence microscopy, demonstrating a link between SOCT and fluorescence imaging.  相似文献   

8.
Laser-induced fluorescence measurements of velocity within a Hall discharge   总被引:1,自引:0,他引:1  
The results of a study of laser-induced fluorescence velocimetry of neutral and singly ionized xenon in the plume and interior portions of the acceleration channel of a Hall thruster plasma discharge operating at powers ranging from 250 to 725 W are described. Axial ion and neutral velocity profiles for four discharge voltage conditions (100 V, 160 V, 200 V, 250 V) are measured as are radial ion velocity profiles in the near-field plume. Ion velocity measurements of axial velocity both inside and outside the thruster as well as radial velocity measurements outside the thruster are performed using laser-induced fluorescence with nonresonant signal detection on the xenon ion 5d[4]7/2–6p[3]5/2 excitation transition while monitoring the signal from the 6s[2]3/2–6p[3]5/2transition. Neutral axial velocity measurements are similarly performed in the interior of the Hall thruster using the 6s[3/2]0 2–6p[3/2]2transition with resonance fluorescence collection. Optical access to the interior of the Hall thruster is provided by a 1-mm-wide axial slot in the insulator outer wall. While the majority of the ion velocity measurements used partially saturated fluorescence to improve the signal-to-noise ratio, one radial trace of the ion transition was taken in the linear fluorescence region and yields a xenon ion translational temperature between 400 and 800 K at a location 13 mm into the plume. Received: 27 September 2000 / Revised version: 2 March 2001 / Published online: 9 May 2001  相似文献   

9.
We describe a novel optical system for bidirectional color Doppler imaging of flow in biological tissues with micrometer-scale resolution and demonstrate its use for in vivo imaging of blood flow in an animal model. Our technique, color Doppler optical coherence tomography (CDOCT), performs spatially localized optical Doppler velocimetry by use of scanning low-coherence interferometry. CDOCT is an extension of optical coherence tomography (OCT), employing coherent signal-acquisition electronics and joint time-frequency analysis algorithms to perform flow imaging simultaneous with conventional OCT imaging. Cross-sectional maps of blood flow velocity with <50-microm spatial resolution and <0.6-mm/s velocity precision were obtained through intact skin in living hamster subdermal tissue. This technology has several potential medical applications.  相似文献   

10.
We have developed a novel phase-resolved optical coherence tomography (OCT) and optical Doppler tomography (ODT) system that uses phase information derived from a Hilbert transformation to image blood flow in human skin with fast scanning speed and high velocity sensitivity. Using the phase change between sequential scans to construct flow-velocity imaging, this technique decouples spatial resolution and velocity sensitivity in flow images and increases imaging speed by more than 2 orders of magnitude without compromising spatial resolution or velocity sensitivity. The minimum flow velocity that can be detected with an axial-line scanning speed of 400 Hz and an average phase change over eight sequential scans is as low as 10 microm/s, while a spatial resolution of 10 microm is maintained. Using this technique, we present what are to our knowledge the first phase-resolved OCT/ODT images of blood flow in human skin.  相似文献   

11.
Solvent effects on 2,3-bis(chloromethyl)-1,4-anthraquinone (DCMAQ) and the molecular recognition of DCMAQ in calix[8]arene were investigated using optical absorption and fluorescence emission techniques. Optical absorption spectra show n→π* band in 350–500 nm region. It also indicates that the dipole–dipole interaction and solvent reorganization energies are responsible for the observed features in different solvents. The observed quantum yield of DCMAQ in different solvents is due to the formation of intermolecular hydrogen bond and reorientation of solvent molecule in the excited state of DCMAQ. Excited state dipole moment of DCMAQ is calculated by solvatochromic data and it shows a higher excited state dipole moment than ground state dipole moment. Optical absorption and fluorescence studies of DCMAQ in calix[8]arene elucidate the evidence for the formation of complex between DCMAQ and calix[8]arene. The inclusion ratios and inclusion constant of the host–guest complexes are also determined.  相似文献   

12.
A Dynamic Programming based Optical Flow technique has been applied to the Particle Image Velocimetry (PIV) problem. It has been used for the extraction of dense velocity fields in a planar section of a fluid flow illuminated by a thin laser light sheet. Two (in-plane) components of the velocity vectors can be recovered using a single camera and all three components can be recovered using two or three cameras. Quantitative performance tests have been carried out on calibrated synthetic image sequences from the PIV Standard Project of the Visualization Society of Japan (VSJ). Results are presented for the 2D flow based sequences (STD01 to STD08 Standard Images) and the 3D flow based sequences (STD301, STD302, STD331 and STD337 Standard Images). The RMS error is within the 2–3% range and within the 4–8% range for recovery of the two-component and the three-component velocity vectors respectively.  相似文献   

13.
We demonstrated in vivo cross-sectional imaging of human fingers by non-mechanical scanning optical coherence tomography (OCT), using a diffracted light as the reference beam and a linear illumination beam at a center wavelength of 1.3 μm for deeper penetration into biological tissues. By applying the three-step phase-shifting method, our system can measure OCT images at 10 frames/s with a sensitivity of 90 dB for a 2.45 × 4.80 mm (axial × lateral) measurement range using an InGaAs digital camera (320 × 256 pixels).  相似文献   

14.
Optical coherence tomography (OCT) is a noninvasive technique that provides micrometer-scale imaging of tissue. As most biological tissues are considered turbid, it causes attenuation of the OCT signal and limits the depth penetration. Although a few algorithms had been developed to compensate the attenuation, almost all of them need to extract the scattering parameters before doing the compensation procedure. Because the real biological samples are anisotropic and multilayer-like structure, it is not time-efficient to model and solve these scattering parameters. This paper introduces a new method to compensate the OCT signal attenuation in depth. By analyzing the input signal, a compensation function is adaptively derived for each A-scan line, which can be used effectively to compensate the energy loss in the large sections and enhance the details in the deep, dark-like areas. Three bio-samples, a piece of onion, a Poecilia Wingei fish and a piece of rabbit abdominal aorta, were used to test our method. OCT images obtained by a swept-source OCT system were processed by the proposed method. Results show the visualization of structures in OCT images has been evidently improved, especially in deep region.  相似文献   

15.
A blind deconvolution method using the concept of subband filter banks has been proposed. This method makes possible the speedy convergence of solution, due to estimation of supports of the reconstructed images by a deconvolution in the lower layer. We apply the method to blind deconvolution by a simulated annealing algorithm and confirm its usefulness. Presented at 1996 International Topical Meeting on Optical Computing (OC’96), April 21–25, Sendai, Japan.  相似文献   

16.
Optical properties, including luminescence, of scandium-doped α-Al2O3 crystals have been studied in the VUV range. An absorption band associated with the scandium impurity was observed at the fundamental-absorption edge of crystalline corundum. A strong luminescence band peaking at 5.6 eV, which is most effectively excited within the 7.7–8.8-eV interval, was found. The kinetic and polarization characteristics of this luminescence were studied within the temperature range 6–500 K. An excitation model of the impurity complex and the mechanism of its relaxation are discussed. Fiz. Tverd. Tela (St. Petersburg) 40, 653–654 (April 1998)  相似文献   

17.
Lauri  J.  Bykov  A. V.  Priezzhev  A. V.  Myllylä  R. 《Laser Physics》2011,21(4):813-817
Time domain Doppler Optical Coherence Tomography (DOCT) technique was applied to measure flow velocity profiles in highly scattering media. We analyzed the distortions of the measured velocity profiles of the 1% Intralipid solution flow embedded into the scattering medium at different embedding depths. For this purpose a tissue phantom consisting of a plain glass capillary (inner diameter 0.3 mm) embedded into a slab of Intralipid solution mimicking human skin was designed. The measured flow velocity profiles and behavior of distortions caused by multiple scattering are shown.  相似文献   

18.
光学相干层析多普勒成像功能拓展研究   总被引:8,自引:0,他引:8  
光学多普勒成像(Optical Doppler tomography,ODT)是一种结合了光学相干层析成像技术(Opticalcoherence tomography,OCT)和多普勒流速仪的非侵入、非接触的成像技术,能够实现对高散介质组织内部的血管分布和血液流速的探测。阐述了基于数字希尔伯特变换的相位分离多普勒光学相干层析成像技术的工作原理,并且通过对玻璃毛细管和生物芯片微通道管中聚苯乙烯溶液流速的实验测量,准确测量管内微粒缓慢移动时的多普勒频移量,获得了玻璃管内和生物芯片微通道管中流速分布曲线,证实了所提方法的可行性。获取的多普勒图像具有较高的空间分辨力和速度分辨力,在未来的临床应用中有潜在的应用价值。  相似文献   

19.
Saxer CE  de Boer JF  Park BH  Zhao Y  Chen Z  Nelson JS 《Optics letters》2000,25(18):1355-1357
A high-speed single-mode fiber-based polarization-sensitive optical coherence tomography (PS OCT) system was developed. With a polarization modulator, Stokes parameters of reflected flight for four input polarization states are measured as a function of depth. A phase modulator in the reference arm of a Michelson interferometer permits independent control of the axial scan rate and carrier frequency. In vivo PS OCT images of human skin are presented, showing subsurface structures that are not discernible in conventional OCT images. A phase retardation image in tissue is calculated based on the reflected Stokes parameters of the four input polarization states.  相似文献   

20.
光学相干断层扫描成像新技术OCT   总被引:9,自引:0,他引:9  
光学相干层析成像技术(optical coherence tomography,简称OCT)是一种新型成像方法,在生物医学和材料等许多领域有广泛的应用。本文介绍了OCT的基本原理,并给出了用该装置对生物组织样品的成像结果。此外还用计算机图像处理的方法,使得图像分辨率得到了进一步提高。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号