Examination of Validity of Paraxial Approximation in Second Harmonic Generation Microscopy under Low Numerical Aperture |
| |
Authors: | WANG Xiang-Hui LIN Lie CHANG Sheng-Jiang ZHANG Hao HAO Shu-Juan |
| |
Affiliation: | Institute of Modern Optics, Key Laboratory of Opto-electronic Information Science and Technology (Ministry of Education), Nankai University, Tianjin 300071 |
| |
Abstract: | By using a vectorial approach, the validity of paraxial approximation in second harmonic generation (SHG) microscopy under low numerical aperture (NA) is examined when the sample is a collagen fibril. Due to the larger value of dzzx and tensorial nature of SHG, the component Ez of the focused field may have strong effect on the radiation pattern of SHG. Numerical results indicate that when the value of NA exceeds 0.3, the effect of Ez can not be neglected, which results in the invalidation of paraxial approximation in SHG microscopy despite the fact that SHG microscopy is still under low NA focusing. |
| |
Keywords: | 42 65 Ky 87 64 Mn 87 50 Wf |
本文献已被 维普 等数据库收录! |
| 点击此处可从《中国物理快报》浏览原始摘要信息 |
|
点击此处可从《中国物理快报》下载免费的PDF全文 |
|