首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A comparison of laser ablation inductively coupled plasma mass spectrometry,micro X-ray fluorescence spectroscopy,and laser induced breakdown spectroscopy for the discrimination of automotive glass
Authors:Benjamin E Naes  Sayuri Umpierrez  Scott Ryland  Cleon Barnett  Jose R Almirall
Institution:1. Florida International University, Department of Chemistry and Biochemistry, International Forensic Research Institute, 11200 SW 8th Street, Miami, FL 33199, United States;2. Florida Department of Law Enforcement, Orlando Regional Crime Laboratory, 500 West Robinson Street, Orlando, FL 32801, United States
Abstract:Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), micro X-ray fluorescence spectroscopy (μXRF), and laser induced breakdown spectroscopy (LIBS) are compared in terms of discrimination power for a glass sample set consisting of 41 fragments. Excellent discrimination results (> 99% discrimination) were obtained for each of the methods. In addition, all three analytical methods produced very similar discrimination results in terms of the number of pairs found to be indistinguishable. The small number of indistinguishable pairs that were identified all originated from the same vehicle. The results also show a strong correlation between the data generated from the use of µXRF and LA-ICP-MS, when comparing µXRF strontium intensities to LA-ICP-MS strontium concentrations. A 266 nm laser was utilized for all LIBS analyses, which provided excellent precision (< 10% RSD for all elements and < 10% RSD for all ratios, N = 5). The paper also presents a thorough data analysis review for forensic glass examinations by LIBS and suggests several element ratios that provide accurate discrimination results related to the LIBS system used for this study. Different combinations of 10 ratios were used for discrimination, all of which assisted with eliminating Type I errors (false exclusions) and reducing Type II errors (false inclusions). The results demonstrate that the LIBS experimental setup described, when combined with a comprehensive data analysis protocol, provides comparable discrimination when compared to LA-ICP-MS and μXRF for the application of forensic glass examinations. Given the many advantages that LIBS offers, most notably reduced complexity and reduced cost of the instrumentation, LIBS is a viable alternative to LA-ICP-MS and μXRF for use in the forensic laboratory.
Keywords:LA-ICP-MS  LIBS  XRF  Glass  Forensic
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号