首页 | 本学科首页   官方微博 | 高级检索  
     检索      

高效阴离子交换色谱-脉冲安培检测法测定烤烟中的水溶性葡萄糖、果糖和蔗糖
引用本文:王荔,陈巧珍,宋国新,沈轶,刘百战.高效阴离子交换色谱-脉冲安培检测法测定烤烟中的水溶性葡萄糖、果糖和蔗糖[J].色谱,2006,24(2):201-204.
作者姓名:王荔  陈巧珍  宋国新  沈轶  刘百战
作者单位:1.Center of Analysis & Measurement, Fudan University, Shanghai 200433, China;2.Shanghai Tobacco (Group) Corporation, Shanghai 200082, China
基金项目:复旦大学校科研和教改项目
摘    要:用高效阴离子交换色谱-脉冲安培检测法(HPAEC-PAD)测定了烤烟中的水溶性葡萄糖、果糖和蔗糖。采用水浸取及膜过滤法处理烤烟样品,以Dionex CarboPac PA-1阴离子交换柱为色谱柱,0.2 mol/L NaOH水溶液为淋洗液进行分离测定。葡萄糖、果糖和蔗糖的含量与其峰面积的线性关系良好,回收率均在97%以上。方法简便易行,灵敏度高,重现性良好,可以实现对烟草中单糖的快速分离和测定。

关 键 词:高效阴离子交换色谱  果糖  烤烟  脉冲安培检测法  葡萄糖  蔗糖  
文章编号:1000-8713(2006)02-0201-04
收稿时间:2005-05-23
修稿时间:2005年5月23日

Determination of Water-Soluble Glucose, Fructose and Sucrose in Flue-Cured Tobacco by High Performance Anion Exchange Chromatography Coupled with Pulsed Amperometric Detection
WANG Li,CHEN Qiaozhen,SONG Guoxin,SHEN Yi,LIU Baizhan.Determination of Water-Soluble Glucose, Fructose and Sucrose in Flue-Cured Tobacco by High Performance Anion Exchange Chromatography Coupled with Pulsed Amperometric Detection[J].Chinese Journal of Chromatography,2006,24(2):201-204.
Authors:WANG Li  CHEN Qiaozhen  SONG Guoxin  SHEN Yi  LIU Baizhan
Institution:1.Center of Analysis & Measurement, Fudan University, Shanghai 200433, China;2.Shanghai Tobacco (Group) Corporation, Shanghai 200082, China
Abstract:The quantitative determination of water-soluble sugars such as glucose, fructose and sucrose in flue-cured tobacco by high performance anion exchange chromatography coupled with pulsed amperometric detection (HPAEC-PAD) was developed. The method was used to determine flue-cured tobacco samples containing large amounts of carbohydrates after pretreatment by water-leaching and membrane filtration. The separation was performed on a Dionex CarboPac PA-1 anion exchange column with 0.2 mol/L NaOH solution as the eluent at a flow rate of 1.0 mL/min. The injection volume was 20 microL. Good linearities were obtained for glucose, fructose and sucrose within the range of 0.5-100 mg/L (r2 > 0.997). The detection limits (S/N = 3) were 0.1 mg/L, 0.1 mg/L and 0.2 mg/L, and the average recoveries were 97.3%, 101.4% and 98.9% with good reproducibility for glucose, fructose and sucrose, respectively.
Keywords:high performance anion exchange chromatography(HPAEC)  pulsed amperometric detection(PAD)  glucose  fructose  sucrose  flue-cured tobacco
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号