首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基质固相分散-高效液相色谱法测定鲫鱼肌肉中残留的辛硫磷
引用本文:刘茜,刘晓宇,邱朝坤,王小宝,任红敏.基质固相分散-高效液相色谱法测定鲫鱼肌肉中残留的辛硫磷[J].色谱,2009,27(4):476-479.
作者姓名:刘茜  刘晓宇  邱朝坤  王小宝  任红敏
作者单位:College of Food Science and Technology, Huazhong Agricultural University, Wuhan 430070, China
基金项目:湖北省自然科学基金资助项目 
摘    要:建立了鲫鱼肌肉中残留的辛硫磷的基质固相分散-高效液相色谱-二极管阵列检测(MSPD-HPLC-DAD)的分析方法。通过优化样品处理条件,确定选取0.50 g鲫鱼肌肉样品与1.5 g弗罗里硅土、0.5 g无水硫酸钠混合研磨,并采用丙酮-正己烷溶液(体积比为40:60)为洗脱剂,洗脱剂用量为25 mL。优选的最佳色谱条件为:ODS色谱柱(250 mm×4.6 mm,5 μm),流动相为甲醇-水(体积比为50:50),流速0.6 mL/min,检测波长270 nm,进样量为20 μL。在上述条件下,辛硫磷质量浓度在0.01~10 mg/L范围内与响应信号呈良好的线性关系(r20.9994),检出限为3.3 μg/kg;相对标准偏差为1.1%~6.3%(n7);3个添加水平(0.05,0.1,1 mg/kg)下得到的回收率为88%~112%。该方法操作简单,耗时少,精密度高,符合农残分析的要求。

关 键 词:残留  高效液相色谱  基质固相分散  鲫鱼  农药  辛硫磷  
收稿时间:2009-2-10
修稿时间:2009-4-10

Application of matrix solid-phase dispersion for the determination of phoxim in crucian carp samples by high performance liquid chromatography
LIU Qian,LIU Xiaoyu,QIU Chaokun,WANG Xiaobao,REN Hongmin.Application of matrix solid-phase dispersion for the determination of phoxim in crucian carp samples by high performance liquid chromatography[J].Chinese Journal of Chromatography,2009,27(4):476-479.
Authors:LIU Qian  LIU Xiaoyu  QIU Chaokun  WANG Xiaobao  REN Hongmin
Institution:College of Food Science and Technology, Huazhong Agricultural University, Wuhan 430070, China
Abstract:An analytical method was developed for the determination of phoxim residue in the muscle of crucian carp, which involved matrix solid-phase dispersion (MSPD) followed by high performance liquid chromatography (HPLC) with diode array detector. Under optimal conditions, 0.5 g tissue sample was dispersed with 1.5 g Florisil and 0.5 g anhydrous sodium sulphate, transferred to a cartridge. The cartridge was eluted with 25 mL acetone-hexane (40:60, v/v). The phoxim was separated on an ODS column (250 mm×4.6 mm, 5 μm) with methanol-water (50:50, v/v) as the mobile phase at the flow rate of 0.6 mL/min, then detected by a diode array detector at 270 nm. The injection volume was 20 μL. The linear range of the method was 0.01~10 mg/L and the detection limit was 3.3 μg/kg. The average recoveries spiked at the levels of 0.05, 0.1, 1 mg/kg ranged from 88% to 112% with the relative standard deviations (RSDs) of 1.1% ~6.3%. The method is quick, simple and can meet the requirement of the analysis of pesticide residues.
Keywords:matrix solid-phase dispersion (MSPD)  high performance liquid chromatography (HPLC)  phoxim  pesticide  residue  crucian carp
本文献已被 万方数据 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号