首页 | 本学科首页   官方微博 | 高级检索  
     检索      

微透析与高效液相色谱在线联用技术校正大鼠皮下阿魏酸线性探针
引用本文:王丹,刘春生,刘艳霞,安卓玲,李鹏飞,刘丽宏,石力夫,胡晋红.微透析与高效液相色谱在线联用技术校正大鼠皮下阿魏酸线性探针[J].分析化学,2012,40(1):164-168.
作者姓名:王丹  刘春生  刘艳霞  安卓玲  李鹏飞  刘丽宏  石力夫  胡晋红
作者单位:1. 第二炮兵总医院,北京,100088
2. 第三军医大学,重庆,400038
3. 第二军医大学长海医院药学部,上海,200433
摘    要:采用微透析与高效液相在线联用技术(MD-HPLC on-line)建立并验证大鼠皮下阿魏酸微透析线性探针体内外校正方法.以磷酸盐缓冲溶液为灌流液,微透析灌注液流速为2 μ L/min,10孔自动进样阀间隔为8 min,在以Hypersil-C18(250 mm×4.6 mm,5μm)为色谱柱,流动相为甲醇-水(含0.5%乙酸)(35∶ 65,V/V),流速1 mL/min,检测波长314 nm的HPLC色谱条件下进行在线检测,阿魏酸在0.1~80 mg/L范围内回归方程线性关系良好,A=159044C-2607 (r=1),阿魏酸日内精密度RSD分别为0.8%,0.3%和0.5%(n=5);日间精密度RSD分别为0.2%,0.3%和0.4%(n=5),重现性与稳定性RSD分别为0.7%和1.1%(n=5).增量法和减量法测定阿魏酸线性探针体内外回收率分别为47.23%±0.94%和20.37%±1.37%,阿魏酸适宜进行微透析实验.应用MD-HPLC on-line对中药当归阿魏酸进行测定,使取样、进样和分析监测同时进行.

关 键 词:高效液相色谱  微透析  在线联用技术  阿魏酸  线性探针

Calibration of Ferulic Acid Linear Probe in Rat Skin by MicrodialysisHigh Performance Liquid Chromatography On-line Technique
WANG Dan , LIU Chun-Sheng , LIU Yan-Xia , AN Zhuo-Ling , LI Peng-Fen , LIU Li-Hong , SHI Li-Fu , HU Jin-Hong.Calibration of Ferulic Acid Linear Probe in Rat Skin by MicrodialysisHigh Performance Liquid Chromatography On-line Technique[J].Chinese Journal of Analytical Chemistry,2012,40(1):164-168.
Authors:WANG Dan  LIU Chun-Sheng  LIU Yan-Xia  AN Zhuo-Ling  LI Peng-Fen  LIU Li-Hong  SHI Li-Fu  HU Jin-Hong
Institution:1(General Hospital of the Second Artillery,Beijing 100088) 2(Second Military Medical University,Shanghai 200433) 3(Third Military Medical University,Chongqing 400038)
Abstract:Microdialysis(MD)-HPLC on-line technique was develop to validate the calibration of ferulic acid linear probe in rat skin,by using phosphate buffer(pH 7.4) as perforates and at perfusion flow rate of 2 μL/min with 8-min intervals.The collective samples were separated by Hypersil-C18 column(250 mm×4.6 mm,5 μm) with mobile phase of methanol-water(0.5% acetic acid)(35:65,V/V) at a flow rate of 1 mL/min and detected at wavelength of 314 nm.The linearity was established for the range of concentrations of 0.1-80 mg/L with a coefficient of determination(r) of 1.The Intra-precision RSDs were 0.8%,0.3%,0.5%(n=5);inter precision RSDs were 0.2%,0.3%,0.4%(n=5),and reproducibility and stability RSD were 0.7%,1.1%(n=5).In vitro and in vivo recovery was calculated by Loss and Gain respectively,and the results were 47.23%±0.94% and 20.37%±1.37%,respectively.We can conclude that microdialysis sampling can be used for the calibration study of ferulic acid.The Chinese angelica ferulic acid was determined by MD-HPLC on-line technique,so that the sampling,injection and analysis can be implemented at the same time.
Keywords:High performance liquid chromatography  Microdialysis  On-line technique  Ferulic acid  Linear probe
本文献已被 CNKI 万方数据 等数据库收录!