首页 | 本学科首页   官方微博 | 高级检索  
     检索      

微波溶样-AAS法测定麻黄素浸膏粉中的12种元素
引用本文:易新萍,陈冬芸,刘建平,刘清旺.微波溶样-AAS法测定麻黄素浸膏粉中的12种元素[J].光谱学与光谱分析,2003,23(1):81-83.
作者姓名:易新萍  陈冬芸  刘建平  刘清旺
作者单位:1. 新疆大学分析测试中心,新疆,乌鲁木齐,830046
2. 新疆维吾尔自治区药品检验所,新疆,乌鲁木齐,830000
3. 新疆大学化学与化工学院,新疆,乌鲁木齐,830046
基金项目:新疆大学校基金资助项目
摘    要:微波溶样技术具有方便快捷、节约试剂、污染少、样品溶解完全等特点。本文采用HNO3 H2O2 微波溶样 ,利用原子吸收分光光度法 ,通过对麻黄素浸膏粉中Fe,Ca ,Mg,Zn ,Mn,Cu ,Na ,K ,Ni,Cd ,Pb ,Cr元素的测定 ,进行了微波消化条件的选择及消化结果精密度实验 ,并利用国家标准物质茶树叶GBW0 850 1验证了方法的准确度 ,测定值与标准值基本吻合。实验结果表明 ,该方法获得了满意的精密度、准确度。

关 键 词:原子吸收法  微波溶样  麻黄素浸膏粉  微量元素
文章编号:1000-0593(2003)01-0081-03
修稿时间:2001年12月27

Determination of Twelve Elements in Ephedrine Extraction by Microwave Digestion-AAS
YI Xin-ping,CHEN Dong-yun,LIU Jian-ping and LIU Qing-wang . Physical and Chemical Test Center,Xinjiang University,Urumqi ,China . Xinjiang Institute of Medicine Test,Urumqi ,China . College of Chemistry and Chemical Engineering,Xinjiang University,Urumqi ,China.Determination of Twelve Elements in Ephedrine Extraction by Microwave Digestion-AAS[J].Spectroscopy and Spectral Analysis,2003,23(1):81-83.
Authors:YI Xin-ping  CHEN Dong-yun  LIU Jian-ping and LIU Qing-wang Physical and Chemical Test Center  Xinjiang University  Urumqi  China Xinjiang Institute of Medicine Test  Urumqi  China College of Chemistry and Chemical Engineering  Xinjiang University  Urumqi  China
Institution:Physical and Chemical Test Center, Xinjiang University, Urumqi 830046, China.
Abstract:The sample digested by microwave are of some merits: simple, rapid, saving agents, nonpollution and being easyly digested. Microwave-digested sample with HNO 3-H 2O 2 and AAS method were established for the determination of Fe, Ca, Mg, Zn, Mn, Cu, Na, K, Ni, Cd, Pb and Cr in ephedrine extraction. In this paper, the selection of digestion conditions, including pressure, power, acids and time of digestion was evaluated. According to standard sample GBW08501 Tea-leaves, we checked the method accuracy and precision. The accuracy values are in the range of 91.1%-105%. The RSDs of flame atomic spectrometry and graphite furnace atomic spectrometry are in the range of 0.2%-2.3% and less than 7%, respectively. The results are very consistent with the the reference values. It proved that the method has satisfactory precision and accuracy. The proposed method is simple, rapid, of nonpollution and safe. It was has been applied to the determination of trace elements in ephedrine extraction and provided useful data for production in factory.
Keywords:AAS  Microwave  digestion  Ephedrine extraction  Trace element
本文献已被 CNKI 维普 万方数据 等数据库收录!