首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Direct observation of uncoated spectrin with atomic force microscope
作者姓名:张平城  白春礼  成英俊  方晔  冯立明  潘华珍
作者单位:Scanning Tunneling Microscopy Laboratory,Institute of Chemistry,Chinese Academy of Sciences,Beijing 100080,China,Scanning Tunneling Microscopy Laboratory,Institute of Chemistry,Chinese Academy of Sciences,Beijing 100080,China,Scanning Tunneling Microscopy Laboratory,Institute of Chemistry,Chinese Academy of Sciences,Beijing 100080,China,Scanning Tunneling Microscopy Laboratory,Institute of Chemistry,Chinese Academy of Sciences,Beijing 100080,China,Institute of Basic Sciences,Chinese Academy of Medical Sciences,Beijing 100005,China,Institute of Basic Sciences,Chinese Academy of Medical Sciences,Beijing 100005,China
基金项目:Project supported by the National Natural Science Foundation of China
摘    要:Spectrin molecules extracted from human blood ceil membrane have been examined by atomic force microscopy (AFM) without using shadowing or staining procedures. A drop of the solution containing spectrin molecules was deposited on the freshly deaved mica substrate. After about 1 min, the residual solution was removed with a piece of filter paper. Afterwards the sample was imaged with a home-made atomic force microscope (AFM) in air in a constant force mode. The obtained AFM images revealed that the spectrin molecules prepared from the above procedures exhibit several kinds of structures as follows: (i) the compact rod-like spectrin heterodimers with a length of around 100 nm; (ii) bent or curved linear tetramers with a length of around 200 nm; (iii) somewhat curved spectrin hexamers, octomers or decamers with lengths of about 300, 400, or 500 nm; and (iv) high oligomers with a length above 1 000 nm.


Direct observation of uncoated spectrin with atomic force microscope
ZHANG Pingcheng BAI Chunli CHENG YingjunFANG Ye.Direct observation of uncoated spectrin with atomic force microscope[J].Science in China(Chemistry),1996(4).
Authors:ZHANG Pingcheng BAI Chunli CHENG YingjunFANG Ye
Abstract:Spectrin molecules extracted from human blood ceil membrane have been examined by atomic force microscopy (AFM) without using shadowing or staining procedures. A drop of the solution containing spectrin molecules was deposited on the freshly deaved mica substrate. After about 1 min, the residual solution was removed with a piece of filter paper. Afterwards the sample was imaged with a home-made atomic force microscope (AFM) in air in a constant force mode. The obtained AFM images revealed that the spectrin molecules prepared from the above procedures exhibit several kinds of structures as follows: (i) the compact rod-like spectrin heterodimers with a length of around 100 nm; (ii) bent or curved linear tetramers with a length of around 200 nm; (iii) somewhat curved spectrin hexamers, octomers or decamers with lengths of about 300, 400, or 500 nm; and (iv) high oligomers with a length above 1 000 nm.
Keywords:atomic force microscopy (AFM)  spectrin  red blood cell  structure  
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号