等速电泳-高效液相色谱联用分离复杂样品的研究
引用本文:阮源萍,刘文远,胡荣宗,穆纪千,洪少群,张长弓.等速电泳-高效液相色谱联用分离复杂样品的研究[J].色谱,1999,17(1):49-51.
作者姓名:阮源萍  刘文远  胡荣宗  穆纪千  洪少群  张长弓
作者单位:厦门大学化学系国家教委分析科学开放实验室
摘    要:将OCEP-1型等速电泳仪和Waters高效液相色谱仪主要部件联用,配以自制的接口,建立高效液相色谱-等速电泳新联用系统,成功地研究了含蛋白质和一些金属离子的复杂样品的分离分析。

关 键 词:等速电泳  高效液相色谱法  联用方法  

Study on the Combination of Isotachophoresis and High Performance Liquid Chromatography for the Separation of Complex Samples
Ruan Yuanping,Liu Wenyuan,Hu Rongzong,Mu Jiqian,Hong Shaoqun and Zhang Changgong.Study on the Combination of Isotachophoresis and High Performance Liquid Chromatography for the Separation of Complex Samples[J].Chinese Journal of Chromatography,1999,17(1):49-51.
Authors:Ruan Yuanping  Liu Wenyuan  Hu Rongzong  Mu Jiqian  Hong Shaoqun and Zhang Changgong
Institution:Department of Chemistry, Research Laboratory of SEDC of Analytical Science for Material and Life Process, Xiamen University, Xiamen, 361005.
Abstract:A method on the combination of isotachophoresis (ITP) and high performance liquid chromatography (HPLC) for the separation and analysis of the complex samples containing proteins and metals is proposed. The instrumental system consisted of a self-made Model OCEP-1 isotachophoresis analyser, main parts of Waters high performance liquid chromatograph and a self-made Model IHI-1 interface. The interface is simple and convenient to use. The injection volume of the interface was determined accurately with a neutralization titration method. In ITP experiment the leading electrolyte was 2.5 mmol/L HCl containing 30 mmol/L of 18-crown-6; the terminating electrolyte was 5 mmol/L Tris+Cl-(pH 6.0); ITP current, 40 microA; detection of metal ions, potential gradient detector. In HPLC experiment the column was a mu-Bondapak C18, reversed-phase column, 4 mm x 200 mm, 10 microns, 12.5 nm; the mobile phase A, V(isopropanol with 5% volume fraction):V(butanol) = 2:1 containing 2.2 mmol/L HCl (pH 2.63); the mobile phase B, V(isopropanol with 50% volume fraction):V(butanol) = 2:1; low pressure gradient elution, mobile phase B changed from 0 to 70% in 17.5 minutes; flow rate, 1.0 mL/min; detection wavelength 225 nm; temperature, 25 degrees C. The experimental results showed that proteins were interfered in the determination of the metals with ITP method. It also showed that HPLC with the use of C18 column can separate the proteins but not the metal ions. By using this new combination system, a complex sample of the proteins and metal ions was injected to the HPLC, the proteins Lys, BSA and OVA were well separated in HPLC, while NH4+, K+, Na+, and Ca2+ were less retained and eluted first. Then the latter was introduced into the system of the ITP with the aid of the interface for separation. Satisfactory results were obtained.
Keywords:isotachophoresis  high performance liquid chromatography  combination method