首页 | 本学科首页   官方微博 | 高级检索  
     检索      

毛细管电泳多脉冲溶出安培检测方法的研究
引用本文:夏之宁,Bo SVENSMARK,肖尚友,孙冠芸,杨玉书.毛细管电泳多脉冲溶出安培检测方法的研究[J].色谱,2000,18(5):379-382.
作者姓名:夏之宁  Bo SVENSMARK  肖尚友  孙冠芸  杨玉书
作者单位:1. 重庆大学环境与化学化工学院,重庆,400044;哥本哈根大学化学院,丹麦,哥本哈根,DK-2100Φ
2. 哥本哈根大学化学院,丹麦,哥本哈根,DK-2100Φ
3. 重庆大学环境与化学化工学院,重庆,400044
基金项目:国家自然科学基金!资助项目 (编号 :2 97750 35),丹麦自然科学研究理事会资助项目! (940 0 2 34),教育部优秀青年教师基金
摘    要: 摘要:将用于电化学检测的三电极与驱动电泳分离的电化学系统的接地电极在毛细管出口处的外面作适当的布置,可最大程度地减少高压电场对安培检测的干扰。多阶脉冲溶出安培检测方式提高了电流检测灵敏度,并可在一定程度上通过不同的溶出电位鉴别分离组分。将该方法应用于铜、锌、铅、铊、镉等离子的毛细管电泳分离,得到了较满意的结果。

关 键 词:毛细管电泳  多脉冲溶出  安培检测  重金属  微电极
修稿时间:1999-11-04

The Application of Multi-Pulse Stripping Amperometric Detection to Capillary Electrophoresis
XIA Zhi-ning,Bo SVENSMARK,XIAO Shang-you,SUN Guan-yun,YANG Yu-shu.The Application of Multi-Pulse Stripping Amperometric Detection to Capillary Electrophoresis[J].Chinese Journal of Chromatography,2000,18(5):379-382.
Authors:XIA Zhi-ning  Bo SVENSMARK  XIAO Shang-you  SUN Guan-yun  YANG Yu-shu
Institution:Institute of Environment and Chemistry and Chemical Engineering, Chongqing University, Chongqing 400044, China. zhanxia@cta.cq.cn
Abstract:There are some drawbacks in amperometric detection in capillary electrophoresis since there is influence of high voltage from electrophoretic instrument. Three electrodes of electrochemical detection system and electrochemical system of capillary electrophoresis are separately placed in capillary outlet buffer reservoir, which can lead to a reduction in the influence of high voltage in the great degree. A carbon fiber with diameter of 7 microns is used as working electrode, and placed just at the separation capillary outlet. The multi-pulse stripping amperometric detection has 1.1 s deposition step and several stripping steps with 0.02 s, which can increase the detection amperometric current and identify the species of each separated component in some classes by different pulse stripping potentials. This detection technique was applied in the separation of Cu, Zn, Pb, Tl and Cd of 25 mg/L by the capillary electrophoresis, and separation efficiency is over 60 thousands theoretical plates. The limit of the multi-pulse stripping amperometry detection was 0.10 microgram/L for cadmium by using water plug field amplified injection.
Keywords:capillary electrophoresis  multi  pulse stripping  amperometric detection  heavy metals  microelectrode  
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号