首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于胆红素荧光增强效应的锌离子探针特性研究
引用本文:郑名,曹思敏,刘阳依,曹潇丹,陈壮,闫姝君,李昊阳,陈缙泉,徐建华.基于胆红素荧光增强效应的锌离子探针特性研究[J].光谱学与光谱分析,2020(3):813-816.
作者姓名:郑名  曹思敏  刘阳依  曹潇丹  陈壮  闫姝君  李昊阳  陈缙泉  徐建华
作者单位:华东师范大学精密光谱科学与技术国家重点实验室
基金项目:国家自然科学基金委面上项目基金(11674101,21873030)资助
摘    要:锌离子Zn^2+对胆红素BR有着显著的荧光增强效应,基于该荧光特性,利用紫外可见光吸收和稳态荧光光谱技术提出了一种BR作为荧光探针用于Zn^2+浓度检测的新方法,特别是首次采用在波长663和600nm处的稳态荧光强度比值方法系统地研究了其与锌离子浓度在0~90μmol·L^-1范围内变化的关系,与常用的单波长荧光强度探测方法比较,有效地避免了探针浓度变化及激发光强度变化等非目标因素的影响。实验研究结果发现BR荧光探针对Zn^2+的识别行为在0~20μmol·L^-1范围内,探针BR的荧光强度比值I663 nm/I600 nm与Zn^2+的浓度之间具备线性增长关系,尤其是0~10μmol·L^-1有非常好的线性关系,线性相关系数r=0.999 87,同时Zn^2+检测限为0.1μmol·L^-1。在20~90μmol·L^-1范围内,荧光强度比值I663 nm/I600 nm趋于饱和。研究发现对实时检测人体内的Zn^2+具有很好的应用前景。

关 键 词:胆红素  锌离子探针  荧光光谱技术

Study on Characteristics of Zinc Ion Probe Based on Fluorescence Enhancement of Bilirubin
ZHENG Ming,CAO Si-min,LIU Yang-yi,CAO Xiao-dan,CHEN Zhuang,YAN Shu-jun,LI Hao-yang,CHEN Jin-quan,XU Jian-hua.Study on Characteristics of Zinc Ion Probe Based on Fluorescence Enhancement of Bilirubin[J].Spectroscopy and Spectral Analysis,2020(3):813-816.
Authors:ZHENG Ming  CAO Si-min  LIU Yang-yi  CAO Xiao-dan  CHEN Zhuang  YAN Shu-jun  LI Hao-yang  CHEN Jin-quan  XU Jian-hua
Institution:(State Key Laboratory of Precision Spectroscopy,East China Normal University,Shanghai 200062,China)
Abstract:Based on the fluorescence enhancement effect of Zn^2+ on bilirubin(BR), this work proposes a new method for the detection of Zn^2+ concentration, and a systematically investigation of BR as a Zn^2+ probe by using ultraviolet-visible light absorption and steady-state fluorescence spectroscopy has been conducted. Compared with the general single-wavelength fluorescence intensity method, this new detection method eliminates the impacts of the non-target effects of factors such as concentration variation of BR and the excitation light intensity, etc., and achieves a more accurate measurement capability in Zn^2+ detection. Especially, for the first time we adopt the BR fluorescence intensities ratio at the emission wavelengths 663 and 600 nm, and investigate the dependence between this ratio and the Zn^2+ concentration in the range from 0 to 90 μmol·L^-1. The recognition behavior of BR probe to Zn^2+ indicates that the BR fluorescence intensity ratio I663 nm/I600 nm increases linearly with the Zn^2+ concentration in the range of 0~20 μmol·L^-1. In particular, in the range 0~10 μmol·L^-1 of Zn^2+ concentration, the linear correlation coefficient r is 0.999 87, which demonstrates the linear dependence, and the detection limit is 0.1 μmol·L^-1. In the Zn^2+ concentration range from 20 to 90 μmol·L^-1, the probe BR fluorescence intensity ratio is saturated. Accordingly, there is a positive prospect of BR fluorescence in the real-time human body Zn^2+ detection.
Keywords:Bilirubin  Zinc probe  Fluorescence spectroscopy
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号