首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Simple test system for single molecule recognition force microscopy
Authors:Christian K Riener  Andreas Ebner  Alex A Gall  Yuri L Lyubchenko  Hermann J Gruber
Institution:a Institute of Biophysics, J. Kepler University, Altenberger Street 69, A-4040 Linz, Austria
b Institute of Chemistry, J. Kepler University, Altenberger Street 69, A-4040 Linz, Austria
c Koronis Pharmaceuticals Inc., Suite 110, 12277 134th Court NE, Redmond, WA 98052, USA
d Department of Microbiology, Arizona State University, Tempe, AZ, USA
Abstract:We have established an easy-to-use test system for detecting receptor-ligand interactions on the single molecule level using atomic force microscopy (AFM). For this, avidin-biotin, probably the best characterized receptor-ligand pair, was chosen. AFM sensors were prepared containing tethered biotin molecules at sufficiently low surface concentrations appropriate for single molecule studies. A biotin tether, consisting of a 6 nm poly(ethylene glycol) (PEG) chain and a functional succinimide group at the other end, was newly synthesized and covalently coupled to amine-functionalized AFM tips. In particular, PEG800 diamine was glutarylated, the mono-adduct NH2-PEG-COOH was isolated by ion exchange chromatography and reacted with biotin succinimidylester to give biotin-PEG-COOH which was then activated as N-hydroxysuccinimide (NHS) ester to give the biotin-PEG-NHS conjugate which was coupled to the aminofunctionalized AFM tip. The motional freedom provided by PEG allows for free rotation of the biotin molecule on the AFM sensor and for specific binding to avidin which had been adsorbed to mica surfaces via electrostatic interactions. Specific avidin-biotin recognition events were discriminated from nonspecific tip-mica adhesion by their typical unbinding force (∼40 pN at 1.4 nN/s loading rate), unbinding length (<13 nm), the characteristic nonlinear force-distance relation of the PEG linker, and by specific block with excess of free d-biotin. The convenience of the test system allowed to evaluate, and compare, different methods and conditions of tip aminofunctionalization with respect to specific binding and nonspecific adhesion. It is concluded that this system is well suited as calibration or start-up kit for single molecule recognition force microscopy.
Keywords:AFM  atomic force microscope (or microscopy)  APS  3-aminopropyltriethoxysilatrane  APTES  3-aminopropyl-triethoxysilane  biotin-NHS  succinimidyl ester of biotin  biotin-PEG-COOH and biotin-PEG-NHS  see Fig  2  HOOC-PEG-COOH  N  N&prime  -bis-glutaryl derivative of NH2-PEG-NH2  DACA  p-dimethylaminocinnamaldehyde  DIEA  N  N-diisopropyl-N-ethylamine  DMF  N  N-dimethylformamide  DMSO  dimethylsulfoxide  ESI-MS  electrospray mass spectrum (or spectrometry)  glu  glutaryl residue  MRFM  molecular recognition force microscopy  NH2-PEG-NH2O  O&prime  -bis(2-aminopropyl)poly(ethylene glycol) 800  NH2-PEG-COOH  N-glutaryl derivative of NH2-PEG-NH2  NHS  N-hydroxysuccinimide  NMR  nuclear magnetic resonance  PEG  poly(ethylene glycol)  RT  room temperature  SDT  single dye tracing  SMRFM  single molecule recognition force microscopy  Su  succinimidyl residue  TEA  N  N  N-triethylamine  TSTU  N  N  N&prime    N&prime  -tetramethyl (succinimido) uronium tetrafluoroborate  X-PEG-NH2  impurity of NH2-PEG-NH2 with one inert terminus  X-PEG-X  PEG with two inert end groups
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号