首页 | 本学科首页   官方微博 | 高级检索  
     检索      

A boron-lined proportional counter (BLPC) used in a mixed field of reactors
作者姓名:陈国云  魏志勇  辛勇  雷升杰  黄福成  黄三玻  朱立  赵经武  马加一
作者单位:1. Nanjing University of Aeronautics & Astronautics, Nanjing 210016, China;;2. Department of Physics, Nanchang University, Nanchang 330031, China;;3. College of Physics, Nanjing University, Nanjing 210093, China
摘    要:A boron-lined proportional counter (BLPC) with a count rate limit close to the multi-wire proportional counter was manufactured to measure the mixed field around reactors. After measurement with a standard Am-Be neutron source (activity: 100 mCi), the results show that the operating voltage of the BLPC is 800 V, the plateau length is 100 V and the slope is 13.2%/100 V. The width and rise time of the output pulse of the BLPC are 1.26 μs and 370 ns, respectively. When the BLPC works at a count rate of 1.0×105 count/s, the pulse pile-up probability of the BLPC is 3.6%. A clear peak can be seen in the pulse height spectrum of the BLPC. and the performances illustrate that a BLPC working in pulse mode can serve as a source range detector of reactors.

关 键 词:BLPC  mixed  field  count  rate  plateau  curve
收稿时间:2011-4-11
修稿时间:2011-12-2

A boron-lined proportional counter (BLPC) used in a mixed field of reactors
CHEN Guo-Yun,;,WEI Zhi-Yong,;,XIN Yong,LEI Sheng-Jie,HUANG Fu-Cheng,HUANG San-Bo,ZHU Li,ZHAO Jing-Wu,MA Jia-Yi.A boron-lined proportional counter (BLPC) used in a mixed field of reactors[J].High Energy Physics and Nuclear Physics,2012,36(5):434-437.
Authors:CHEN Guo-Yun  ;  WEI Zhi-Yong  ;  XIN Yong  LEI Sheng-Jie  HUANG Fu-Cheng  HUANG San-Bo  ZHU Li  ZHAO Jing-Wu  MA Jia-Yi
Institution:1 Nanjing University of Aeronautics & Astronautics, Nanjing 210016, China 2 Department of Physics, Nanchang University, Nanchang 330031, China 3 College of Physics, Nanjing University, Nanjing 210093, China
Abstract:A boron-lined proportional counter (BLPC) with a count rate limit close to the multi-wire proportional counter was manufactured to measure the mixed field around reactors. After measurement with a standard Am-Be neutron source (activity: 100 mCi), the results show that the operating voltage of the BLPC is 800 V, the plateau length is 100 V and the slope is 13.2%/100 V. The width and rise time of the output pulse of the BLPC are 1.26 μs and 370 ns, respectively. When the BLPC works at a count rate of 1.0 × 10 5 count/s, the pulse pile-up probability of the BLPC is 3.6%. A clear peak can be seen in the pulse height spectrum of the BLPC. and the performances illustrate that a BLPC working in pulse mode can serve as a source range detector of reactors.
Keywords:BLPC  mixed field  count rate  plateau curve
本文献已被 CNKI 等数据库收录!
点击此处可从《中国物理 C》浏览原始摘要信息
点击此处可从《中国物理 C》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号