排序方式: 共有69条查询结果,搜索用时 296 毫秒
1.
Sunil K. Ghosh 《Helvetica chimica acta》2023,106(11):e202300141
Acrylates are well known electrophilic alkenes having multitude of applications in organic synthesis. They are very good acceptors in Michael addition reactions and are good enophile/dienophile/dipolarophile partners in cycloaddition reactions. Replacing the β-alkyl/aryl groups in acrylates by a silicon group would be interesting. In addition to the conventional reactions displayed by acrylates, β-silylacrylates (β-SAs) can show reactivity specifically related to the silicon group. Many conventional organic reactions such as hydrodimerization, organocatalytic asymmetric Michael additions, inter- and intra-molecular Diels–Alder reactions, and asymmetric 1,3-dipolar cycloadditions have been used to generate the complex chemical entities from β-SAs. Some of the reaction outcomes were vastly influenced by the silicon substituent. This review describes the practical synthesis β-SAs and their use as starting point in complex molecule generation including total synthesis of some natural products/bioactive molecules. 相似文献
2.
David M. Rackham 《光谱学快报》2013,46(8):517-520
Paper 16 in this series1, 2, 3 was concerned with the equilibrium binding constants (K) of the shift reagent Europium tris (2, 2, 6, 6-tetramethylheptane-3, 5-dionate), Eu(thd)3, with primary, secondary and tertiary amines. One nitrogen heterocycle, pyridine, and two of its derivatives (see Table) were included. In the present paper we describe the binding constants for a further 9 nitrogen containing heterocycles and relate these to basicity and steric effects. 相似文献
3.
Liangnian He Yanping Luo Kai Li Guangfu Yang Mingwu Ding Xiaopeng Liu 《Phosphorus, sulfur, and silicon and the related elements》2013,188(11):2675-2678
A convenient one-pot synthesis of fused phosphorus-heterocycles with biological activity via the cyclization reactions of Lawesson's reagent with bifunctional substrates is reported. 相似文献
4.
Susana Meseguer-Lloret Carmen Molins-Legua Pilar Campins-Falco 《International journal of environmental analytical chemistry》2013,93(7):475-489
A selective and sensitive method based on the ammonium derivatisation with o -phthaldialdehyde (OPA) and N -acetyl-cysteine (NAC) has been developed for ammonium determination in real water samples. The proposed procedure has been compared with ammonium reference methods such as Nessler reagent method and ammonium selective electrode. All procedures have been chemometrically tested and compared in terms of the main analytical properties. These procedures have been used to determine ammonium in unknown water samples. The OPA-NAC reagent method does not present any systematic error (proportional or constant), while Nessler reagent presents both of them for some samples assayed. The ammonium selective electrode is free of corrigible systematic errors, however presents amine interference. The OPA-NAC ammonium method is able to achieve a detection limit (LOD) of 0.07 mg/L in the sample, with a linear dynamic range up to 1.4 mg/L of ammonium. 相似文献
5.
原子吸收法间接测定泥炭水解物中的还原糖 总被引:1,自引:0,他引:1
本文研究是在常规分析基础上,提出的原子吸收法间接测定泥炭水解物中还原糖的方法。并探讨了方法中酸性介质、共存元素的影响等问题。本方法与常规方法比较,具有测定速度快,试剂用量少,准确性、重现性高等优点。 相似文献
6.
The determination of inorganic phosphorus in human urine is very important, since it has diagnostic value in some clinical
cases. Here we apply a simple, sensitive and direct method to determine inorganic phosphorus in urine. This new ensemble is
prepared by adding ytterbium chloride and pyrocatechol violet in a 2:1 molar ratio in an aqueous solution of 10 mM 2-[4-(2-hydroxyethyl)-1-piperazinyl]ethanesulfonic
acid buffer at pH 7.0. The addition of the urine sample turned the blue ensemble yellow and altered the UV–vis absorption
spectra. The ensemble exhibits excellent selectivity for inorganic phosphorus over other constituents of urine. We validate
the accuracy of our method by the standard procedure (molybdenum blue assay for phosphate). The detection results are basically
consistent with normal excretion of phosphate. Furthermore, we fabricated a new kind of inorganic phosphorus reagent kit,
which enables us to inspect phosphate concentrations of urine with the naked eye. Fit for all kinds of various clinic uses,
our reagent kit is a hopeful substitute for the molybdenum reagent kit.
相似文献
7.
This study examines the reagent gas pressure and ion source temperature dependence for dimethyl ether chemical ionization (DME CI) mass spectra recorded with an external source ion trap mass spectrometer (ITMS). Information for better controls of the reagent gas pressure in order to obtain fair CI spectra is provided. The origin of M+? ions observed in DME CIMS is discussed in detail. Furthermore, the ion source temperature effect on the DME CI is also investigated. 相似文献
8.
9.
10.
This paper describes an acoustic method for inducing rotating vortex flows in microchannels. An ultrasonic crystal is used to create an acoustic standing wave field in the channel and thus induce a Rayleigh flow transverse to the laminar flow in the channel. Mixing in microchannels is strictly diffusion-limited because of the laminar flow, a transverse flow will greatly enhance mixing of the reactants. This is especially evident in chemical microsystems in which the chemical reaction is performed on a solid phase and only one reactant is actually diffusing. The method has been evaluated on two different systems, a mixing channel with two parallel flows and a porous silicon micro enzyme reactor for protein digestion. In both systems a significant increase of the mixing ratio is detected in a narrow band of frequency for the actuating ultrasound. 相似文献