首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   53篇
  免费   2篇
化学   50篇
物理学   5篇
  2015年   6篇
  2014年   9篇
  2013年   8篇
  2012年   7篇
  2011年   8篇
  2010年   7篇
  2009年   2篇
  2008年   2篇
  2007年   2篇
  2006年   1篇
  2005年   1篇
  1997年   1篇
  1981年   1篇
排序方式: 共有55条查询结果,搜索用时 31 毫秒
1.
This is the part II of a tutorial review intending to give an overview of the state of the art of method validation in liquid chromatography mass spectrometry (LC–MS) and discuss specific issues that arise with MS (and MS–MS) detection in LC (as opposed to the “conventional” detectors). The Part II starts with briefly introducing the main quantitation methods and then addresses the performance related to quantification: linearity of signal, sensitivity, precision, trueness, accuracy, stability and measurement uncertainty. The last section is devoted to practical considerations in validation. With every performance characteristic its essence and terminology are addressed, the current status of treating it is reviewed and recommendations are given, how to handle it, specifically in the case of LC–MS methods.  相似文献   
2.
This is the part I of a tutorial review intending to give an overview of the state of the art of method validation in liquid chromatography mass spectrometry (LC–MS) and discuss specific issues that arise with MS (and MS/MS) detection in LC (as opposed to the “conventional” detectors). The Part I briefly introduces the principles of operation of LC–MS (emphasizing the aspects important from the validation point of view, in particular the ionization process and ionization suppression/enhancement); reviews the main validation guideline documents and discusses in detail the following performance parameters: selectivity/specificity/identity, ruggedness/robustness, limit of detection, limit of quantification, decision limit and detection capability. With every method performance characteristic its essence and terminology are addressed, the current status of treating it is reviewed and recommendations are given, how to determine it, specifically in the case of LC–MS methods.  相似文献   
3.
A chiral ligand exchange capillary electrophoresis (CLE-CE) method using Zn(II) as the central ion and l-4-hydroxyproline as the chiral ligand coordinating with γ-cyclodextrin (γ-CD) was developed for the enantioseparation of amino acids (AAs) and dipeptides. The effects of various separation parameters, including the pH of the running buffer, the ratio of Zn(II) to l-4-hydroxyproline, the concentration of complexes and cyclodextrins (CDs) were systematically investigated. After optimization, it has been found that eight pairs of labeled AAs and six pairs of labeled dipeptides could be baseline-separated with a running electrolyte of 100.0 mM boric acid, 5.0 mM ammonium acetate, 3.0 mM Zn(II), 6.0 mM l-hydroxyproline and 4.0 mM γ-CD at pH 8.2. The quantitation of AAs and dipeptides was conducted and good linearity (r2 ≥ 0.997) and favorable repeatability (RSD ≤ 3.6%) were obtained. Furthermore, the proposed method was applied in determining the enantiomeric purity of AAs and dipeptides. Meanwhile, the possible enantiorecognition mechanism based on the synergistic effect of chiral metal complexes and γ-CD was explored and discussed briefly.  相似文献   
4.
In most diseases, the clinical need for serum/plasma markers has never been so crucial, not only for diagnosis, but also for the selection of the most efficient therapies, as well as exclusion of ineffective or toxic treatment. Due to the high sample complexity, prefractionation is essential for exploring the deep proteome and finding specific markers.In this study, three different sample preparation methods (i.e., highly abundant protein precipitation, restricted access materials (RAM) combined with IMAC chromatography and peptide ligand affinity beads) were investigated in order to select the best fractionation step for further differential proteomic experiments focusing on the LMW proteome (MW inferior to 40,000 Da). Indeed, the aim was not to cover the entire plasma/serum proteome, but to enrich potentially interesting tissue leakage proteins. These three methods were evaluated on their reproducibility, on the SELDI-TOF-MS peptide/protein peaks generated after fractionation and on the information supplied.The studied methods appeared to give complementary information and presented good reproducibility (below 20%). Peptide ligand affinity beads were found to provide efficient depletion of HMW proteins and peak enrichment in protein/peptide profiles.  相似文献   
5.
The paper presents a new method based on simultaneous derivatization and air-assisted liquid–liquid microextraction (AALLME) for the extraction and preconcentration of some aliphatic amines prior to gas chromatography-flame ionization detection (GC-FID). Primary aliphatic amines are derivatized and extracted simultaneously by a fast reaction with butylchloroformate (derivatization agent/extraction solvent) under mild conditions. The mixture of butylchloroformate and aqueous sample solution is rapidly sucked into a 10-mL glass syringe and then is injected into a test tube with conical bottom and the procedure is repeated seven times. After centrifuging the resulted cloudy solution, the derivatized analytes in the sedimented phase are determined by GC-FID. The influence of main factors on the efficiency of derivatization/extraction procedure is studied. Under the optimal conditions, the enrichment factors (EFs) for aliphatic amines are obtained in the range of 248–360 and limits of detection (LODs) are between 0.30 and 2.6 μg L−1. The obtained extraction recoveries ranged from 50 to 72% and the relative standard deviation (RSD) was less than 4.8% for intra-day (n = 6) and inter-days (n = 4) precision. The method is successfully applied to determine some aliphatic amines in environmental water samples.  相似文献   
6.
7.
While operational qualification (OQ) is a well-established term within equipment qualification, users of equipment often become unsure when it comes to implementation. The biggest problem is how to select procedures and acceptance criteria. Should these be the vendor's specifications or should the users define their own limits, and, if so, how? Should all instruments of the same type have the same values or should these be optimized for each individual instrument? This article will provide an overall strategy and specific examples for HPLC on how to select procedures and acceptance limits that are based on efficient use of resources, on practicality and on the intended use of the equipment.  相似文献   
8.
Monolithic columns were introduced in the early 1990s and have become increasingly popular as efficient stationary phases for most of the important chromatographic separation modes. Monoliths are functionally distinct from porous particle-based media in their reliance on convective mass transport. This makes resolution and capacity independent of flow rate. Monoliths also lack a void volume. This eliminates eddy dispersion and permits high-resolution separations with extremely short flow paths. The analytical value of these features is the subject of recent reviews. Nowadays, among other types of rigid macroporous monoliths, the polymethacrylate-based materials are the largest and most examined class of these sorbents. In this review, the applications of polymethacrylate-based monolithic columns are summarized for the separation, purification and analysis of low and high molecular mass compounds in the different HPLC formats, including micro- and large-scale HPLC modes.  相似文献   
9.
梁琳  余岳辉  彭亚斌 《中国物理 B》2008,17(7):2627-2632
The power dissipation characteristics of pulsed power switch reversely switched dynistors (RSDs) are investigated in this paper. According to the expressions of voltage on RSD, derived from the plasma bipolar drift model and the RLC circuit equations of RSD main loop, the simulation waveforms of current and voltage on RSD are acquired through iterative calculation by using the fourth order Runge-Kutta method, then the curve of transient power on RSD versus time is obtained. The result shows that the total dissipation on RSD is trivial compared with the pulse discharge energy and the commutation dissipation can be nearly ignored compared with the quasi-static dissipation. These characteristics can make the repetitive frequency of RSD increase largely. The experimental results prove the validity of simulation calculations. The influence factors on power dissipation are discussed. The power dissipation increases with the increase of the peak current and the n-base width and with the decrease of n-base doping concentration. In order to keep a low power dissipation, it is suggested that the n-base width should be smaller than 320μm when doping concentration is 1.0×10^14cm^-3 while the doping concentration should be higher than 5.8×10^13cm^-3 when n-base width is 270μm.  相似文献   
10.
In view of the fact that many substances generally exhibit very little ultraviolet absorbance and the absence of native fluorescence, a new strategy with simple instrumentation and excellent analytical performance combining high performance liquid chromatography (HPLC) with resonance Rayleigh scattering (RRS) was developed. It was validated for the quantification of aminoglycosides (AGs). This fact was also carefully calculated by quantum chemistry. However, the sensitivity was probably limited by the volume of flow-through cell. Therefore, the result calls for a suitable one to ensure optimal RRS signal. Interestingly, when serum or urine samples of analytes were analyzed by this method, they were all well resolved without any interference, which would hold a new perspective to be applied in the determination of substances in biological matrix.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号