首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   15篇
  免费   0篇
  国内免费   1篇
化学   15篇
物理学   1篇
  2015年   1篇
  2014年   1篇
  2013年   1篇
  2012年   3篇
  2009年   3篇
  2008年   1篇
  2007年   1篇
  2005年   1篇
  2004年   1篇
  1997年   1篇
  1992年   1篇
  1990年   1篇
排序方式: 共有16条查询结果,搜索用时 375 毫秒
1.
微波等离子体光谱法测定碲的研究   总被引:2,自引:0,他引:2  
微波等离子体原子发射光谱法(MIPAES)测定碲,前人已作过一些工作。本文利用我们建立的微量进样系统与MIPAES联用,对碲的测定进行了研究。实验中发现,加入适量的SnCl_2可降低检出限约一个数量级,Te_(214.3nm)的检出限为5 ng/mL,同时还研究了碱金属卤化物对碲的测定的影响。  相似文献   
2.
Hou X  Roos P 《Analytica chimica acta》2008,608(2):105-139
The radiometric methods, alpha (α)-, beta (β)-, gamma (γ)-spectrometry, and mass spectrometric methods, inductively coupled plasma mass spectrometry, accelerator mass spectrometry, thermal ionization mass spectrometry, resonance ionization mass spectrometry, secondary ion mass spectrometry, and glow discharge mass spectrometry are reviewed for the determination of radionuclides. These methods are critically compared for the determination of long-lived radionuclides important for radiation protection, decommissioning of nuclear facilities, repository of nuclear waste, tracer application in the environmental and biological researches, these radionuclides include 3H, 14C, 36Cl, 41Ca, 59,63Ni, 89,90Sr, 99Tc, 129I, 135,137Cs, 210Pb, 226,228Ra, 237Np, 241Am, and isotopes of thorium, uranium and plutonium. The application of on-line methods (flow injection/sequential injection) for separation of radionuclides and automated determination of radionuclides is also discussed.  相似文献   
3.
氟化电热蒸发/ICP—AES直接测定SiO2中痕量Fe   总被引:1,自引:0,他引:1  
对氟化电热蒸发(FETV)/ICP-AES技术中元素的氟化蒸发行为,基体效应和粒度效应进行了考察,确定了杂质(Fe)与基体(Si)分离的最佳实验条件,本法用于SiO2中痕量Fe的直接测定,有灵敏,简便,试样消耗少和不需化学处理等优点。  相似文献   
4.
We review recent progress in preconcentration strategies associated to vapor generation techniques coupled to atomic spectrometric (VGT-AS) for specific chemical species detection. This discussion focuses on the central role of different preconcentration approaches, both before and after VG process. The former was based on the classical solid phase and liquid–liquid extraction procedures which, aided by automation and miniaturization strategies, have strengthened the role of VGT-AS in several research fields including environmental, clinical, and others. We then examine some of the new vapor trapping strategies (atom-trapping, hydride trapping, cryotrapping) that entail improvements in selectivity through interference elimination, but also they allow reaching ultra-low detection limits for a large number of chemical species generated in conventional VG systems, including complete separation of several species of the same element. This review covers more than 100 bibliographic references from 2009 up to date, found in SCOPUS database and in individual searches in specific journals. We finally conclude by giving some outlook on future directions of this field.  相似文献   
5.
Spectral interference is one of the main causes of erroneous results in Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). This paper describes some cases of spectral interferences with conventional nebulization ICP-OES and the potential of solving them utilizing electrothermal vaporization for volatility-based separation. The cases studied were, the well-known spectral overlap between the As and Cd lines at 228.8 nm that are only 10 pm apart, and the interference of Fe on the main emission lines of As, Cd and Pb. The spectral interferences were studied by monitoring the typical signals of solutions that contain the analytes and the potential interferent, by studying the spectra and calculating Background Equivalent Concentration (BEC)-values. A three step temperature program was developed to be used for direct analysis of solid soil samples by Electrothermal Vaporization (ETV)-ICP-OES: step 1 (760 °C, 40 s), step 2 (1620 °C, 20 s) and a cleaning step (2250 °C, 10 s) where Cd vaporizes in step 1, As, Pb and part of Fe in step 2 and the major part of Fe in the cleaning step. Because As and Cd were time-separated using this program, their prominent lines at 228.8 nm, could be used for determination of each element by ETV-ICP-OES, in spite of the serious wavelength overlap. Selective vaporization was also shown to reduce or eliminate the Fe background emission on As, Cd and Pb lines. To confirm the applicability of the method, a solid soil certified reference materials was analyzed directly without any sample treatment. Good or reasonable accuracy was obtained for the three elements.  相似文献   
6.
The members of the committee NMP 264 “Chemical analysis of non-oxidic raw and basic materials” of the German Standards Institute (DIN) have organized two interlaboratory comparisons for multielement determination of trace elements in silicon carbide (SiC) powders via direct solid sampling methods. One of the interlaboratory comparisons was based on the application of inductively coupled plasma optical emission spectrometry with electrothermal vaporization (ETV ICP OES), and the other on the application of optical emission spectrometry with direct current arc (DC arc OES). The interlaboratory comparisons were organized and performed in the framework of the development of two standards related to “the determination of mass fractions of metallic impurities in powders and grain sizes of ceramic raw and basic materials” by both methods. SiC powders were used as typical examples of this category of material. The aim of the interlaboratory comparisons was to determine the repeatability and reproducibility of both analytical methods to be standardized. This was an important contribution to the practical applicability of both draft standards. Eight laboratories participated in the interlaboratory comparison with ETV ICP OES and nine in the interlaboratory comparison with DC arc OES. Ten analytes were investigated by ETV ICP OES and eleven by DC arc OES. Six different SiC powders were used for the calibration. The mass fractions of their relevant trace elements were determined after wet chemical digestion. All participants followed the analytical requirements described in the draft standards. In the calculation process, three of the calibration materials were used successively as analytical samples. This was managed in the following manner: the material that had just been used as the analytical sample was excluded from the calibration, so the five other materials were used to establish the calibration plot. The results from the interlaboratory comparisons were summarized and used to determine the repeatability and the reproducibility (expressed as standard deviations) of both methods. The calculation was carried out according to the related standard. The results are specified and discussed in this paper, as are the optimized analytical conditions determined and used by the authors of this paper. For both methods, the repeatability relative standard deviations were <25%, usually ~10%, and the reproducibility relative standard deviations were <35%, usually ~15%. These results were regarded as satifactory for both methods intended for rapid analysis of materials for which decomposition is difficult and time-consuming. Also described are some results from an interlaboratory comparison used to certify one of the materials that had been previously used for validation in both interlaboratory comparisons. Thirty laboratories (from eight countries) participated in this interlaboratory comparison for certification. As examples, accepted results are shown from laboratories that used ETV ICP OES or DC arc OES and had performed calibrations by using solutions or oxides, respectively. The certified mass fractions of the certified reference materials were also compared with the mass fractions determined in the interlaboratory comparisons performed within the framework of method standardization. Good agreement was found for most of the analytes.  相似文献   
7.
The determination of trace metals in lubricating oils using atomic spectrometric methods is reviewed. The importance of such analyses for technical diagnostics as well as the specific sample characteristics related to the analyte form (metallo-organic and metal particles) is discussed. Problems related to sample pre-treatment for appropriate sample introduction and calibration are addressed as well as the strategies to overcome them. Recent trends aimed at simplifying sample manipulation are presented. The applications and scope of AAS, ICP OES and ICP MS techniques for the determination of trace metals in lubricating oil is individually discussed, as well as some present instrumental trends.  相似文献   
8.
《Analytical letters》2012,45(4):809-822
Abstract

A new method based on cloud point extraction (CPE) separation and electrothermal vaporization inductively coupled plasma optical emission spectrometry (ETV‐ICP‐OES) detection was proposed for the determination of chromium species. Thenoyltrifluoracetone (TTA) was used as both an extractant for CPE of Cr(III) and a chemical modifier for ETV‐ICP‐OES determination. When the system temperature is higher than the cloud point temperature (CPT) of the selected surfactant, Triton X‐114, the complex of Cr(III) with TTA could enter the surfactant‐rich phase, whereas the Cr(VI) remained in aqueous solutions. Thus, an in situ separation of Cr(III) and Cr(VI) could be realized. The concentrated analyte was introduced into ETV‐ICP‐OES for determination of Cr(III) after proper disposal. Cr(VI) is reduced to Cr(III) prior to determining total Cr, and its assay is based on substracting of Cr(III) from total chromium. The main factors affecting cloud point extraction and the vaporization behavior of the analyte were investigated in detail. Under the optimized conditions, the limit of detection (LOD) for Cr(III) was 0.22 µg/L by preconcentration of a 10 mL sample solution, and the relative standard deviation (RSD) was 3.8% (CCr(III)=0.5 µg/mL, n=5). The proposed method was applied to the speciation of chromium in different water samples. In order to verify the accuracy of the method, a certified reference water sample was analyzed, and the results obtained were in good agreement with certified values.  相似文献   
9.
Within the last decade, liquid-phase microextraction (LPME) and micro-solid phase extraction (μSPE) approaches have emerged as substitutes for conventional sample processing procedures for trace metal assays within the framework of green chemistry. This review surveys the progress of the state of the art in simplification and automation of microextraction approaches by harnessing to the various generations of flow injection (FI) as a front end to atomic absorption spectrometry (AAS), atomic fluorescence spectrometry (AFS) or inductively coupled plasma atomic emission spectrometry or mass spectrometry (ICP-AES/MS). It highlights the evolution of flow injection analysis and related techniques as vehicles for appropriate sample presentation to the detector and expedient on-line matrix separation and pre-concentration of trace levels of metals in troublesome matrices. Rather than being comprehensive this review is aimed at outlining the pros and cons via representative examples of recent attempts in automating green sample preparation procedures in an FI or sequential injection (SI) mode capitalizing on single-drop microextraction, dispersive liquid-phase microextraction and advanced sorptive materials including carbon and metal oxide nanoparticles, ion imprinted polymers, superparamagnetic nanomaterials and biological/biomass sorbents. Current challenges in the field are identified and the synergetic combination of flow analysis, nanotechnology and metal-tagged biomolecule detection is envisaged.  相似文献   
10.
ICP—AES的电热蒸发进样技术   总被引:1,自引:0,他引:1  
本文综述了ICP-AES中的电热蒸发进样技术(ETV),内容包括:(1)蒸发器装置及材料;(2)分析性能;(3)干扰;(4)实际样品分析;(5)存在的问题。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号