首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   50篇
  免费   15篇
化学   63篇
物理学   2篇
  2024年   1篇
  2023年   1篇
  2022年   1篇
  2021年   3篇
  2020年   6篇
  2019年   7篇
  2018年   8篇
  2017年   4篇
  2016年   3篇
  2015年   9篇
  2014年   2篇
  2013年   1篇
  2012年   6篇
  2011年   2篇
  2010年   1篇
  2009年   4篇
  2008年   1篇
  2007年   1篇
  2005年   2篇
  2004年   1篇
  2003年   1篇
排序方式: 共有65条查询结果,搜索用时 96 毫秒
1.
Catechin is found in several natural sources, as Eugenia dysenterica and Syzygium cumini extracts. Its antioxidant and UV‐protective properties suggest a potential use in cosmetic and dermatological formulations. A simple analytical method capable of giving support to experiments performed along the development of topical formulations containing this natural substance (i.e. drug assay, skin permeation and stability studies), however, is still needed. Thus, this work aimed to develop and validate a selective HPLC method for catechin determination during the development of topical formulations. Separation was achieved using an RP‐C18 column (300 × 3.9 mm; 10 μm), with a mobile phase of methanol–phosphoric acid 0.01 m (15: 85, v/v), a flow rate of 0.8 mL/min, temperature set at 40°C and UV detection at 230 nm. The method was linear in a range from 0.5 to 10.0 μg/mL (r = 0.9998), precise with an overall variation coefficient of 5.5% and accurate with catechin recovery from the skin layers >85%. Additionally, the method was sensitive (limit of detection, 0.109 μg/mL; limit of quantification, 0.342 μg/mL) and selective against plant extracts, skin matrices and formulation interferents, as well as catechin degradation products. It was also robust regarding both methodology parameters and analytical stability.  相似文献   
2.
A specific and robust LC–MS/MS method was developed and validated for the quantitative determination of GDC‐3280 in human plasma and urine. The nonspecific binding associated with urine samples was overcome by the addition of CHAPS. The sample volume was 25 μL for either matrix, and supported liquid extraction was employed for analyte extraction. d6‐GDC‐3280 was used as the internal standard. Linear standard curves (R2 > 0.9956) were established from 5.00 to 5000 ng/mL in both matrices with quantitation extended to 50,000 ng/mL through dilution. In plasma matrix, the precision (RSD) ranged from 1.5 to 9.9% (intra‐run) and from 2.4 to 7.2% (inter‐run); the accuracy (RE) ranged from 96.1 to 107% (intra‐run) and from 96.7 to 104% (inter‐run). Similarly, in urine the precision was 1.5–6.2% (intra‐run) and 1.9–6.1% (inter‐run); the accuracy was 83.1–99.3% (intra‐run) and 87.1–98.3% (inter‐run). Good recovery (>94%) and negligible matrix effect were achieved in both matrices. Long‐term matrix stability was established for at least 703 days in plasma and 477 days in urine. Bench‐top stability of 25 h and five freeze–thaw cycles were also confirmed in both matrices. The method was successfully implemented in GDC‐3280's first‐in‐human trial for assessing its pharmacokinetic profiles.  相似文献   
3.
Quantitation of drugs used for the treatment of chronic lymphocytic leukemia in various biological matrices during both pre-clinical and clinical developments is very important, often in routine therapeutic drug monitoring. The first developed methods for quantitation were traditionally done on LC in combination with either UV or fluorescence detection. However, the emergence of LC with mass spectrometry in tandem in early 1990s has revolutionized the quantitation as it has provided better sensitivity and selectivity within a shorter run time; therefore it has become the choice of method for the analysis of various drugs. In this article, an overview of various bioanalytical methods (HPLC or LC–MS/MS) for the quantification of drugs for the treatment of chronic lymphocytic leukemia, along with applicability of these methods, is given.  相似文献   
4.
Benznidazole (BNZ) and nifurtimox are the only drugs available for treating Chagas disease. In this work, we validated a bioanalytical method for the quantification of BNZ in plasma aimed at improving sensitivity and time of analysis compared with the assays already published. Furthermore, we demonstrated the application of the method in a preclinical pharmacokinetic study after administration of a single oral dose of BNZ in Wistar rats. A Waters® Acquity UHPLC system equipped with a UV–vis detector was employed. The method was established using an Acquity® UHPLC HSS SB C18 protected by an Acquity® UHPLC HSS SB C18 VanGuard guard column and detection at 324 nm. The mobile phase consisted of ultrapure water–acetonitrile (65:35), and elution was isocratic. The mobile phase flow rate was 0.55 mL/min, the volume of injection was 1 μL, and the run time was just 2 min. The samples were kept at 25°C until injection and the column at 45°C for the chromatographic separation. The sample preparation was performed by a rapid protein precipitation with acetonitrile. The linear concentration range was 0.15–20 µg/mL. The pharmacokinetic parameters of BNZ in rats were determined and the method was considered sensitive, fast and suitable for application in pharmacokinetic studies. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   
5.
Ondansetron, a widely used antiemetic agent, is a P‐glycoprotein (P‐gp) substrate and therefore expression of P‐gp at the blood–brain barrier limits its distribution to the central nervous system (CNS), which was observed to be reversed by coadministration with P‐gp inhibitors. Tariquidar is a potent and selective third‐generation P‐gp inhibitor, and coadministration with ondansetron has shown improved ondansetron distribution to the CNS. There is currently no reported bioanalytical method for simultaneously quantifying ondansetron with a third‐generation P‐gp inhibitor. Therefore, we aimed to develop and validate a method for ondansetron and tariquidar in rat and human plasma samples. A full validation was performed for both ondansetron and tariquidar, and sample stability was tested under various storage conditions. To demonstrate its utility, the method was applied to a preclinical pharmacokinetic study following coadministration of ondansetron and tariquidar in rats. The presented method will be valuable in pharmacokinetic studies of ondansetron and tariquidar in which simultaneous determination may be required. In addition, this is the first report of a bioanalytical method validated for quantification of tariquidar in plasma samples.  相似文献   
6.
A simple, sensitive, selective and robust HPLC method based on intrinsic fluorescence detection was developed for the quantitation of a dodecapeptide (designated as LR12), inhibitor of Triggering Receptor Expressed on Myeloid cells‐1, in rat whole blood. Sample treatment was optimized using protein precipitation and solid‐phase extraction. Chromatographic separation was carried out in a gradient mode using a core–shell C18 column (150 × 4.6 mm, 3.6 μm) with mobile phases of acetonitrile and water containing trifluoroacetic acid at 1.0 mL/min. The method was validated using methodology described by the US Food and Drug Administration guidelines for bioanalytical methods. Linearity was demonstrated within the 50–500 ng/mL range and the lower limit of quantitation was 50 ng/mL. Finally, a preliminary pharmacokinetic study after intraperitoneal injection of LR12 in rats was conducted to evaluate both LR12 monomer and its corresponding disulfide dimer, the main product of degradation. Beyond the fact that this paper describes the first fully validated method for LR12 analysis in blood samples, the approach followed here to optimize pre‐analytical steps could be beneficial to develop HPLC and/or MS methods for other pharmaceutical peptides.  相似文献   
7.
8.
Garcinia cambogia is one of the most commonly used anti-obesity dietary supplements, and hydroxycitric acid (HCA) is a major constituent in the commercial preparations of Garcinia. High doses of HCA are often consumed without much awareness of its pharmacokinetic and toxicokinetic parameters, and therefore, a complete understanding of its effects is lacking. The first step in understanding these parameters is the availability of a reliable bioanalytical method. Here, we present the first report on a UPLC–MS/MS method for analysis of HCA in rat plasma after a simplified and cost-effective protein precipitation. Chromatographic separation of the analytes in the supernatant was achieved using hydrophilic interaction liquid chromatography, where mass parameters were optimized and a rapid 5-min quantitative assay was developed. The method was highly sensitive, accurate, precise and linear in the concentration range of 10.5–5000 ng/mL (validated according to the United States Food and Drug Administration guidelines). Further, the method was successfully used to describe the pharmacokinetic profile of HCA in rat plasma after the administration of pure HCA and commercial Garcinia preparations.  相似文献   
9.
In the present study, a sensitive and fully validated bioanalytical high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed for the quantitative determination of three newly synthesized carbonic anhydrases inhibitors (CAIs) with potential antitumor activity in human plasma. The analytes and the internal standard (IS) were extracted using 1.5 mL acetonitrile from only 450 µL aliquots of human plasma to achieve the desired protein precipitation. Chromatographic separations were achieved on Phenomenex Kinetex® C18 column (100 × 4.6 mm, 2.6 µm) using a binary gradient elution mode with a run time of less than 6 min. The mobile phase consisted of solvent (A): 0.1% formic acid in 50% methanol and solvent B: 0.1% formic acid in acetonitrile (30:70, v/v), pumped at a flow rate of 0.8 mL/min. Detection was employed using triple quadrupole tandem mass spectrometer (API 3500) equipped with an electrospray ionization (ESI) source in the positive ion mode. Multiple reaction monitoring (MRM) mode was selected for quantitation through monitoring the precursor-to-parent ion transition at m/z 291.9 → 173.0, m/z 396.9 → 225.1, m/z 388.9 → 217.0, and m/z 146.9 → 91.0 for AW-9a, WES-1, WES-2, and Coumarin (IS), respectively. Linearity was computed using the weighted least-squares linear regression method (1/x2) over a concentration range of 1–1000, 2.5–800, and 5–500 ng/mL for AW-9a, WES-1, and WES-2; respectively. The bioanalytical LC-MS/MS method was fully validated as per U.S. Food and Drug Administration (FDA) guidelines with all respect to linearity, accuracy, precision, carry-over, selectivity, dilution integrity, and stability. The proposed LC-MS/MS method was applied successfully for the determination of all investigated drugs in spiked human plasma with no significant matrix effect, which is a crucial cornerstone in further therapeutic drug monitoring of newly developed therapeutic agents.  相似文献   
10.
Renal function can be monitored by estimation of the glomerular filtration rate (GFR), for example, through measurement of the plasma clearance of a marker that is freely filtrated through the kidney without reabsorption. It has been proposed that iohexol is the most accurate marker for GFR determination in cats and dogs. However, there is a need for a validated capillary electrophoretic method that covers the concentration range for a full curve clearance estimate of iohexol. In the final method, the plasma samples were protein precipitated and the supernatant was analyzed in a background electrolyte containing borate buffer (0.06 m , pH 10.0). The method developed was proved to be linear (concentration range 18– 2900 mg/L) and had a good precision (e.g. 2.3–2.9% at 88 mg/L) and accuracy (e.g. 101–105% at 88 mg/L). Finally, the method was compared with a previously published and validated HPLC‐UV method by parallel analysis of clinical plasma samples from dogs and cats administered Omnipaque®. This comparison showed excellent agreement between the two methods and no proportional or systematic error was observed. The proposed method is simple and has a low cost per sample, which makes it applicable for routine analysis. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号