首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   9篇
  免费   0篇
化学   4篇
力学   1篇
物理学   4篇
  2013年   1篇
  2003年   1篇
  2002年   2篇
  2001年   2篇
  1999年   2篇
  1910年   1篇
排序方式: 共有9条查询结果,搜索用时 15 毫秒
1
1.
2.
3.
EM Forgan  D Charalambous  PG Kealey 《Pramana》2002,58(5-6):899-901
We have used a variety of microscopic techniques to reveal the structure and motion of flux line arrangements, when the flux lines in low T c type II superconductors are caused to move by a transport current. Using small-angle neutron scattering by the flux line lattice (FLL), we are able to demonstrate directly the alignment by motion of the nearest-neighbor FLL direction. This tends to be parallel to the direction of flux line motion, as had been suspected from two-dimensional simulations. We also see the destruction of the ordered FLL by plastic flow and the bending of flux lines. Another technique that our collaboration has employed is the direct measurement of flux line motion, using the ultra-high-resolution spectroscopy of the neutron spin-echo technique to observe the energy change of neutrons diffracted by moving flux lines. The muon spin rotation (μSR) technique gives the distribution of values of magnetic field within the FLL. We have recently succeeded in performing μSR measurements while the FLL is moving. Such measurements give complementary information about the local speed and orientation of the FLL motion. We conclude by discussing the possible application of this technique to thin film superconductors.  相似文献   
4.
The kinetics of oxidation of amino acids (Arg, His, Lys, Phe, Thr and Tyr), a dipeptide (Gly-His), and BSA (bovine serum albumin) by two persistent water soluble free radicals of the hydrazyl type has been studied.The rate decreases in the order Arg>Lys>Tyr>Thr>HisBSAPheGly-His with bothfree radicals. Addition to the reaction mixture of - and -cyclodextrin decreases the oxidation rate, probably due to amino acidencapsulation in the cyclodextrin cavity. -Cyclodextrin protects more efficiently against oxidation than -cyclodextrin.  相似文献   
5.
Es wurde ein Trennverfahren ausgearbeitet, das es gestattet, die Aktivitätsausbeuten für Mono-, Di- und Triphenylantimonprodukte sowie für nicht organisch gebundenes Antimon in neutronenbestrahlten Phenylantimonverbindungen zu bestimmen. Zur Überführung der verschiedenen Produkte mit gleicher Phenylgruppenzahl am Antimon in eine bestimmte chemische Form wir eine Oxydation oder Reduktion durchgeführt. Als Trennmethoden werden Extraktion, Anionenaustausch und Al2O3-Chromatographie benutzt. Ein Trennschema für die Aufarbeitung folgender bestrahlter Verbindungen wird angegeben: PhSbO, (Ph2Sb)2O, Ph3Sb, PhSbO(OH)2, Ph2SbO(OH) und Ph3Sb(OH)2.  相似文献   
6.
Capillary zone electrophoresis was employed to determine cefazolin, a first-generation cephalosporin antibiotic, in plasma and microdialysis samples from patients. To shorten the analysis, the samples were injected from the short end of the capillary, resulting in a separation time of < 3 min. Due to a high ionic strength of the biological matrices it was necessary to optimize the stacking conditions. For microdialysis samples a 1:10 dilution with water before injection was sufficient to obtain good peak shape. For plasma samples a protein removal step was required to obtain clean electropherograms and a good peak shape. Acetonitrile was used as precipitant resulting in an enhanced sample stacking in comparison to water dilution. The disadvantage of using acetonitrile was severe evaporation loss making quantitation impossible. A self-sealing film was used to seal each individual sample vial to suppress evaporation during long-term sequences. The calibration curves for spiked plasma and cefazolin in Ringer's solutions were linear in the range from 2-500 and 2.5-100 microg/mL, respectively. Limits of detection were 1.0 and 2.0 microg/mL in plasma and microdialysis samples, respectively. The assay was successfully applied to plasma and microdialysis samples obtained in vivo from the interstial space fluid of subcutaneous adipose and muscle tissue of patients undergoing cardiac surgery.  相似文献   
7.
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
8.
On the origin of respiratory artifacts in BOLD-EPI of the human brain   总被引:6,自引:0,他引:6  
BOLD-based functional MRI (fMRI) can be used to explicitly measure hemodynamic aspects and functions of human neuro-physiology. As fMRI measures changes in regional cerebral blood flow and volume as well as blood oxygenation, rather than neuronal brain activity directly, other processes that may change the above parameters have to be examined closely to assess sensitivity and specificity of fMRI results. Physiological processes that can cause artifacts include cardiac action, breathing and vasomotion. Although there has been substantial research on physiological artifacts and appropriate compensation methods, controversy still remains on the mechanisms that cause the fMRI signal fluctuations. Respiratory-correlated fluctuations may either be induced by changes of the magnetic field homogeneity due to moving organs, intra-thoracic pressure differences, respiration-dependent vasodilation or oxygenation differences. The aim of this study was to characterize the impact of different breathing patterns by varying respiration frequency and/or tidal volume on EPI time courses of the resting human brain. The amount of respiration-related oscillations during three respiration patterns was quantified, and statistically significant differences were obtained in white matter only: p < 0.03 between 6 vs. 12 ml/kg body weight end tidal volume at a respiration frequency of 15/min, p < 0.03 between 12 vs. 6 ml/kg body weight and 15 vs. 10 respiration cycles/min. There was no significant difference between 15 vs. 10 respiration cycles/min at an end tidal volume of 6 ml/kg body weight (p = 0.917). In addition, the respiration-affected brain regions were very similar with EPI readout in the a-p and l-r direction. Based on our results and published literature we hypothesize that venous oxygenation oscillations due to changing intra-thoracic pressure represent a major factor for respiration-related signal fluctuations and increase significantly with increasing end tidal volume in white matter only.  相似文献   
9.
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号