首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   13篇
  免费   1篇
化学   8篇
力学   1篇
数学   2篇
物理学   3篇
  2022年   1篇
  2019年   1篇
  2017年   1篇
  2016年   1篇
  2012年   1篇
  2011年   4篇
  2007年   2篇
  2005年   1篇
  1995年   1篇
  1986年   1篇
排序方式: 共有14条查询结果,搜索用时 15 毫秒
1.
After solid organ transplantation, tacrolimus is given to prevent rejection. Therapeutic drug monitoring is used to reach target concentrations of tacrolimus in whole blood. Because the site of action of tacrolimus is the lymphocyte, and tacrolimus binds ~80% to erythrocytes, the intracellular tacrolimus concentration in lymphocytes is possibly more relevant. For this purpose, we aimed to develop, improve and validate a UPLC–MS/MS method to measure tacrolimus concentrations in isolated peripheral blood mononuclear cells (PBMCs). PBMCs were isolated using a Ficoll separation technique, followed by a washing step using red blood cell lysis. A cell suspension of 50 μL containing 1 million PBMCs was used in combination with MagSiMUS‐TDMPREP. To each sample we added 30 μL lysis buffer, 20 μL reconstitution buffer containing 13C2H4‐tacrolimus as internal standard, 40 μL MagSiMUS‐TDMPREP Type I Particle Mix and 175 μL Organic Precipitation Reagent VI for methanol‐based protein precipitation. A 10 μL aliquot of the supernatant was injected into the UPLC–MS/MS system. The method was validated, resulting in high sensitivity and specificity. The method was linear (r2 = 0.997) over the range 5.0–1250 pg/1 × 106 PBMCs. The inaccuracy was <5% and the imprecision was <15%. The washing steps following Ficoll isolation could be performed at either room temperature or on ice, with no effect of the temperature on the results. A method for the analysis of tacrolimus concentrations in PBMCs was developed and successfully validated. Further research will be performed to investigate the correlation between concentrations in PBMCs and clinical outcome.  相似文献   
2.
The antipsychotics risperidone, aripiprazole and pipamperone are frequently prescribed for the treatment in children with autism. The aim of this study was to validate an ultra‐high performance liquid chromatography–mass spectrometry method for the quantification of these antipsychotics in plasma. An ultra‐high performance liquid chromatography–mass spectrometry assay was developed for the determination of the drugs and metabolites. Gradient elution was performed on a reversed‐phase column with a mobile phase consisting of ammonium acetate, formic acid in methanol or in Milli‐Q ultrapure water at a flow rate of 0.5 mL/min. The method was validated according to the US Food and Drug Administration guidelines. The analytes were found to be stable enough after reconstitution and injection of only 5 μL improved the accuracy and precision in combination with the internal standard. Calibration curves of all five analytes were linear. All analytes were stable for at least 72 h in the autosampler and the high quality control of 9‐OH‐risperidone was stable for 48 h. The method allows quantification of all analytes. The advantage of this method is the combination of a minimal injection volume, a short run‐time, an easy sample preparation method and the ability to quantify all analytes in one run. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   
3.
In this paper it is argued that all multivariate estimation methods, such as OLS regression, simultaneous linear equations systems and, more widely, what are known as LISREL methods, have merit as geometric approximation methods, even if the observations are not drawn from a multivariate normal parent distribution and consequently cannot be viewed as ML estimators. It is shown that for large samples the asymptotical distribution of any estimator, being a totally differentiable covariance function, may be assessed by the δ method. Finally, we stress that the design of the sample and a priori knowledge about the parent distribution may be incorporated to obtain more specific results. It turns out that some fairly traditional assumptions, such as assuming some variables to be non-random, fixed over repeated samples, or the existence of a parent normal distribution, may have dramatic effects on the assessment of standard deviations and confidence bounds, if such assumptions are not realistic. The method elaborated by us does not make use of such assumptions.  相似文献   
4.
We present a method to accurately measure the electrophoretic mobility of spherical colloids at high volume fractions in real space using confocal laser scanning microscopy (CLSM) and particle tracking. We show that for polymethylmethacrylate (PMMA) particles in a low-polar, density- and refractive-index-matched mixture of cyclohexylbromide and cis-decahydronaphthalene, the electrophoretic mobility decreases nonlinearly with increasing volume fraction. From the electrophoretic mobilities, we calculate the ζ-potential and the particle charge with and without correcting for volume fraction effects. For both cases, we find a decreasing particle charge as a function of volume fraction. This is in accordance with the fact that the charges originate from chemical equilibria that represent so-called weak association and/or dissociation reactions. Finally, as our methodology also provides data on particle self-diffusion in the presence of an electric field, we also analyze the diffusion at different volume fractions and identify a nonlinear decreasing trend for increasing volume fraction.  相似文献   
5.
在航空航天领域,为了加速系统设计及测试进度,通常需要进行半实物实时仿真,即控制器用实物,受控对象采用数学模型。本文开发出了基于Matlab/Simulink的两相传热模块,并用其搭建了某机械泵驱动两相回路的实时动态模型。通过与实验的对比,验证了模型的可靠性,表明该模型满足实时要求,可以在下一步用于半实物仿真。  相似文献   
6.
We present experiments on pattern formation in a Brownian system of oppositely charged colloids driven by an ac electric field. Using confocal laser scanning microscopy we observe complete segregation of the two particle species into bands perpendicular to a field of sufficient strength when the frequency is in a well-defined range. Because of its Brownian nature the system spontaneously returns to the equilibrium mixture after the field is turned off. We show that band formation is linked to the time scale associated with collisions between particles moving in opposite directions.  相似文献   
7.
The neuraminidase inhibitor oseltamivir (Tamiflu®) is currently the first-line therapy for patients with influenza virus infection. Common analysis of the prodrug and its active metabolite oseltamivircarboxylate is determined via extraction from plasma. Compared with these assays, dried blood spot (DBS) analysis provides several advantages, including a minimum sample volume required for the measurement of drugs in whole blood. Samples can easily be obtained via a simple, non-invasive finger or heel prick. Mainly, these characteristics make DBS an ideal tool for pediatrics and to measure multiple time points such as those needed in therapeutic drug monitoring or pharmacokinetic studies. Additionally, DBS sample preparation, stability, and storage are usually most convenient. In the present work, we developed and fully validated a DBS assay for the simultaneous determination of oseltamivir and oseltamivircarboxylate concentrations in human whole blood. We demonstrate the simplicity of DBS sample preparation, and a fast, accurate and reproducible analysis using ultra high-performance liquid chromatography coupled to a triple quadrupole mass spectrometer. A thorough validation on the basis of the most recent FDA guidelines for bioanalytical method validation showed that the method is selective, precise, and accurate (≤15% RSD), and sensitive over the relevant clinical range of 5–1,500 ng/mL for oseltamivir and 20–1,500 ng/mL for the oseltamivircarboxylate metabolite. As a proof of concept, oseltamivir and oseltamivircarboxylate levels were determined in DBS obtained from healthy volunteers who received a single oral dose of Tamiflu®.  相似文献   
8.
van Elteren JT  Budic B 《Talanta》2005,66(4):925-930
In an earlier paper (Anal. Chim. Acta 514 (2004) 137) we claimed that the maximal extractability of a metal from soil or sediment for a user-defined extractant, i.e. the chemical availability in that particular extractant, may be biased as a result of inadequate volume to mass (V/m) ratios. Correcting for that artifact using an implementation of the simple linear isotherm model gave good results although we cautioned the general applicability. In this paper we will theoretically derive the limitations of that approach based on the more general assumption that sorption processes are described by a Langmuir isotherm.NIST reference material 8704 was extracted with 1 mol l−1 NaOAc (adjusted to pH 5) to experimentally verify the applicability of the Langmuir isotherm approach and illustrate the deviations obtained for some metals using the linear isotherm approach. Of the seven metals measured (Cr, Co, Ni, Cu, Zn, Cd, and Ba) only for Cr and Cu severe discrepancies between both approaches were found, which could be traced back to non-linear isotherm behaviour. Moreover, the Langmuir isotherm approach showed that the above mentioned extractability artifact is even more serious than earlier assumed applying the linear isotherm approach.  相似文献   
9.
Using methanol/water mixtures (from pure water to pure methanol), with different desorption and solubility parameters, and varying extractant volume to algal mass (V/m) ratios, the extractability of arsenic species from CRM IAEA-140/TM was investigated. A linear sorption isotherm-based model was developed to process the data obtained with variable volume extraction, allowing the unambiguous deduction of the maximal extractable species concentrations under the specific extraction conditions, even for more stable species.The maximal extractable arsenic fraction ranged from 41 to 68% of the total arsenic concentration in CRM IAEA-140/TM, depending on the extractant composition, with pure methanol giving the lowest extraction yield and pure water giving erratic extractability (probably due to bad wettability). The main arsenic species quantified in the methanol/water extracts were arsenosugars, with arsenosugars 1 (glycerol arsenosugar), 3 (sulfonate arsenosugar) and 4 (sulfate arsenosugar) making up ca. 90% of the maximal extractable arsenic. The rest accounts for DMA (dimethylarsinate), arsenosugar 2 (phosphate arsenosugar) and As(V). There is no clear extraction pattern emerging from the data although it may be seen that extraction of more polar species (e.g. arsenosugar 1) is favoured in pure methanol and less polar more ionic species (e.g. arsenosugar 2 and As(V)) in methanol extractants with a higher water percentage.The precise and highly accurate data may be used for quality control purposes under strictly followed extraction conditions since the extraction is operationally defined. Additionally, the variable volume extraction methodology presented may be applied to other elemental species in other matrices using other extractants. Although this approach does not maximise the absolute extractability but only that which is extractant-specific, experimentators are forewarned that in most cases only a fingerprint of the extractant-specific species is produced unless a quantitative extraction of all species is obtained.  相似文献   
10.
A new method has been developed to analyse the mobility of elements within soils employing counter-current flow soil contacting in a fluidised bed (FB) column. This method alleviates the problem of irreproducible peaks suffered by state-of-the-art micro-column techniques as a result of particle compaction. Reproducible extraction profiles are produced through the leaching of soil with a linear gradient of 0.05 mol L−1 ammonium sulphate to 0.11 mol L−1 acetic acid using a high pressure liquid chromatography (HPLC) quaternary pump, and the continuous monitoring of the elements in the leachate with inductively coupled plasma mass spectrometry (ICP-MS). Quantification of the procedure is achieved with an external flow injection (FI) calibration method.Flow rate and FB column length were investigated as critical parameters to the efficiency of the extraction methodology. It was found that an increase in the column length from 10 to 20 cm using a flow rate of 0.15 mL min−1 produced the same increase in extracted elemental concentration as an increase in flow rate from 0.15 to 0.30 mL min−1. In both examples, the increase in the concentration of elements leached from the soil may be ascribed to the increase in the concentration gradient between the solid and liquid.The exhaustive nature of the technique defines the maximum leachable concentration within the operationally defined leaching parameters of the exchangeable phase, providing a more accurate assessment of the risk associated with the elements in the soil for the phase providing the greatest risk to the environment.The multi-elemental high sensitivity nature of the on-line detector provides an accurate determination of the associations present between the elements in the soil, and the identification of multiple phases within the exchangeable phase through the presence of multiple peaks in the extraction profiles. It is possible through the deconvolution of these extraction profiles that the concentration corresponding to the peaks identified can be defined.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号