首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   29篇
  免费   0篇
化学   1篇
力学   1篇
物理学   27篇
  2012年   2篇
  2011年   3篇
  2007年   1篇
  2006年   2篇
  2004年   1篇
  2003年   6篇
  2002年   1篇
  2001年   1篇
  2000年   2篇
  1996年   2篇
  1995年   2篇
  1994年   3篇
  1993年   1篇
  1990年   1篇
  1982年   1篇
排序方式: 共有29条查询结果,搜索用时 15 毫秒
1.
2.
3.
4.
5.
Magnetic field fluctuations (and the associated current perturbation) have been measured in the core of a high-temperature reversed-field pinch using a newly developed fast-polarimetry system. Radial magnetic field fluctuation levels of approximately 1% are measured in standard-reversed-field pinch discharges which increase to approximately 4% during the sawtooth crash (enhanced dynamo). The fluctuation level is reduced fourfold for high-confinement plasmas where the core-resonant tearing modes are suppressed.  相似文献   
6.
Measurement of the plasma potential in the core of MST marks both the first interior potential measurements in an RFP, as well as the first measurements by a Heavy Ion Beam Probe (HIBP) in an RFP. The HIBP has operated with (20-110) keV sodium beams in plasmas with toroidal currents of (200-480) kA over a wide range of densities and magnetic equilibrium conditions. A positive plasma potential is measured in the core, consistent with the expectation of rapid electron transport by magnetic fluctuations and the formation of an outwardly directed ambipolar radial electric field. Comparison between the radial electric field and plasma flow is underway to determine the extent to which equilibrium flow is governed by E×B. Measurements of potential and density fluctuations are also in progress.Unlike HIBP applications in tokamak plasmas, the beam trajectories in MST (RFP) are both three-dimensional and temporally dynamic with magnetic equilibrium changes associated with sawteeth. This complication offers new opportunity for magnetic measurements via the Heavy Ion Beam Probe (HIBP). The ion orbit trajectories are included in a Grad-Shafranov toroidal equilibrium reconstruction, helping to measure the internal magnetic field and current profiles. Such reconstructions are essential to identifying the beam sample volume locations, and they are vital in MST's mission to suppress MHD tearing modes using current profile control techniques. Measurement of the electric field may be accomplished by combining single point measurements from multiple discharges, or by varying the injection angle of the beam during single discharges.The application of an HIBP on MST has posed challenges resulting in additional diagnostic advances. The requirement to keep ports small to avoid introducing magnetic field perturbations has led to the design and successful implementation of cross-over sweep systems. High levels of ultraviolet radiation are driving alternative methods of sweep plate operation. While, substantial levels of plasma flux into the HIBP diagnostic chambers has led to the use of magnetic plasma suppression.  相似文献   
7.
An integral equation formulation for buoyancy-driven convection problems is developed and illustrated. Buoyancy-driven convection in a bounded cylindrical geometry with a free surface is studied for a range of aspect ratios and Nusselt numbers. The critical Rayleigh number, the nature of the cellular motion, and the heat transfer enhancement are computed using linear theory. Green's functions are used to convert the linear problem into linear Fredholm integral equations. Theorems are proved which establish the properties of the eigenvalues and eigenfunctions of the linear integral operator which appears in these equations.  相似文献   
8.
We report the first direct measurement of the internal magnetic field structure associated with a 3D helical equilibrium generated spontaneously in the core of an axisymmetric toroidal plasma containment device. Magnetohydrodynamic equilibrium bifurcation occurs in a reversed-field pinch when the innermost resonant magnetic perturbation grows to a large amplitude, reaching up to 8% of the mean field strength. Magnetic topology evolution is determined by measuring the Faraday effect, revealing that, as the perturbation grows, toroidal symmetry is broken and a helical equilibrium is established.  相似文献   
9.
This paper reports a new flow-through fluoroimmunosensor, the function of which is based on antibodies immobilized on an inmunoreactor of controlled-pore glass (CPG), for determination of digoxin, used in the treatment of congestive heart failure and artery disease. The immunosensor has a detection limit of 1.20 microg L(-1) and provides high reproducibility (RSD=4.5% for a concentration of 0.0025 mg L(-1), and RSD=6.7% for 0.01 mg L(-1)). The optimum working concentration range was found to be 1.2 x 10(-3)-4.0 x 10(-2) mg L(-1). The lifetime of the immunosensor was about 50 immunoassays; if stored unused its lifetime can be extended to three months. A sample speed of about 10-12 samples per hour can be attained. Possible interference from substances with structures similar to digoxin (morphine, heroin, tebaine, codeine, pentazocine and narcotine) was investigated. No cross-reactivity was seen at the highest digoxin: interferent ratio studied (1:100). The proposed fluoroimmunosensor was successfully used to determine digoxin concentrations in human serum samples.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号