首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
化学   1篇
物理学   3篇
  2009年   1篇
  1996年   1篇
  1995年   1篇
  1994年   1篇
排序方式: 共有4条查询结果,搜索用时 62 毫秒
1
1.
2.
3.
Cardiac elastography using radiofrequency echo signals can provide improved 2D strain information compared to B-mode image data, provided data are acquired at sufficient frame rates. In this paper, we evaluate ultrasound frame rate requirements for unbiased and robust estimation of tissue displacements and strain. Both tissue-mimicking phantoms under cyclic compressions at rates that mimic the contractions of the heart and in vivo results are presented. Sinusoidal compressions were applied to the phantom at frequencies ranging from 0.5 to 3.5 cycles/sec, with a maximum deformation of 5% of the phantom height. Local displacements and strains were estimated using both a two-step one-dimensional and hybrid two-dimensional cross-correlation method. Accuracy and repeatability of local strains were assessed as a function of the ultrasound frame rate based on signal-to-noise ratio values.The maximum signal-to-noise ratio obtained in a uniformly elastic phantom is 20 dB for both a 1.26 Hz and a 2 Hz compression frequency when the radiofrequency echo acquisition is at least 12 Hz and 20 Hz respectively. However, for compression frequencies of 2.8 Hz and 4 Hz the maximum signal-to-noise ratio obtained is around 16 dB even for a 40 Hz frame rate. Our results indicate that unbiased estimation of displacements and strain require ultrasound frame rates greater than ten times the compression frequency, although a frame rate of about two times the compression frequency is sufficient to estimate the compression frequency imparted to the tissue-mimicking phantom. In vivo results derived from short-axis views of the heart acquired from normal human volunteers also demonstrate this frame rate requirement for elastography.  相似文献   
4.
The retention behaviour of fifteen closely related coumarins in normal-phase overpressured layer chromatography (OPLC) was studied with the aim of comparing the retentions with those in normal-phase thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC) when optimization of the mobile phase was carried out according to the PRISMA system. The mobile phase optimization was carried out on TLC plates in unsaturated chambers. The resulting mobile phases were transposed to off-line, non-equilibrated OPLC and further to HPLC. The retention in TLC was measured at 37 selectivity points and in OPLC and HPLC at 13 points. Capacity factors (k′) and separation factors () were calculated in order to study the retention behaviour in the different systems. Two- and three-dimensional evaluations of k′ against selectivity points showed similar retention behaviours for the coumarins in TLC, OPLC and HPLC. The values for TLC, OPLC and HPLC showed similar patterns in the three-dimensional evaluations. The retention behaviour at different solvent strengths was also examined. According to quadratic regression, k′ showed a dependence on the change in solvent strength. OPLC, which can be considered as a “planar column” technique, and TLC are closely related methods, whereas HPLC shows a different behaviour in the elution process with regard to solvent strength.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号