排序方式: 共有9条查询结果,搜索用时 187 毫秒
1
1.
The observation of isolated positive and negative charges, but not isolated magnetic north and south poles, is an old puzzle. Instead, evidence of effective magnetic monopoles has been found in the abstract momentum space. Apart from Hall-related effects, few observable consequences of these abstract monopoles are known. Here, we show that it is possible to manipulate the monopoles by external magnetic fields and probe them by universal conductance fluctuation measurements in ferromagnets with strong spin-orbit coupling. The observed fluctuations are not noise, but reproducible quasiperiodic oscillations as a function of magnetization direction, a novel Berry phase fingerprint of the magnetic monopoles. 相似文献
2.
M. Leprince R. Lecoq Napoleone Passerini H. Wagner G. Schöler W. E. Joseph M. E. Slater H. S. Grindley H. C. Eckstein J. C. Ross Sigmund Hals Sverre Heggenhougen Erich Ewers C. J. Lintner G. Belschner O. Wenglein Dowzard H. Weller Syniewski F. Mach P. Lederle Honcamp Ries Ad. Beneschovsky Wilk Nördlinger Ralph M. Bohn Krauss A. Jentsch Tacke und E. Blanck 《Fresenius' Journal of Analytical Chemistry》1920,59(1):33-48
Ohne Zusammenfassung 相似文献
3.
M. Leprince R. Lecoq Napoleone Passerini H. Wagner G. Schöler W. E. Joseph M. E. Slater H. S. Grindley H. C. Eckstein J. C. Ross Sigmund Hals Sverre Heggenhougen Erich Ewers C. J. Lintner G. Belschner O. Wenglein Dowzard H. Weller Syniewski F. Mach P. Lederle Honcamp Ries Ad. Beneschovsky Wilk Nördlinger Ralph M. Bohn Krauss A. Jentsch Tacke E. Blanck 《Analytical and bioanalytical chemistry》1920,59(1):33-48
4.
5.
We derive a phenomenological theory of current-induced staggered magnetization dynamics in antiferromagnets. The theory captures the reactive and dissipative current-induced torques and the conventional effects of magnetic fields and damping. A Walker ansatz describes the dc current-induced domain-wall motion when there is no dissipation. If magnetic damping and dissipative torques are included, the Walker ansatz remains robust when the domain wall moves slowly. As in ferromagnets, the domain-wall velocity is proportional to the ratio between the dissipative torque and the magnetization damping. In addition, a current-driven antiferromagnetic domain wall acquires a net magnetic moment. 相似文献
6.
Pekka Niemi Hannu Paajanen Petter-Arnt Hals Minna Tertti Markku Komu Martti Kormano 《Magnetic resonance imaging》1989,7(6):649-653
Gastrointestinal contrast enhancement and image distortion induced by superparamagnetic particles were evaluated in vitro and in rabbits at 0.02 Tesla. Test tubes containing 0.01–1.0 mg particles/ml were imaged in an oil or water bath in order to demonstrate the concentration-dependent signal void and image distortion in vitro at several pulse sequences. The lowest concentration of particles tested clearly decreased the signal intensity. Image distortion was observed when the concentration exceeded 0.07 mg/ml and was more pronounced on the T2-weighted images. The in vitro T2 relaxation time decreased from 122 ms to 56 ms with an increase in the particle concentration from 0.01 to 0.06 mg/ml. A loss of the GI-tract signal was observed in rabbits after the administration of 1 mg particles/kg, given as a 0.03 mg/ml suspension. At a dose of 20 mg/kg (0.6 mg/ml suspension) significant image distortion was observed. 相似文献
7.
Bennett Kivel F.A. Hals 《Journal of Quantitative Spectroscopy & Radiative Transfer》1975,15(1):87-105
A method for calculation of radiation cooling of MHD exhaust gases in a steam generator is given. A two-group radiation transport equation is derived which takes account of both an optically-thick diffusing component with an effective mean-free-path and an optically-thin component. The diffusing components cools the region near the wall making a radiation boundary layer. Real gas emissivities are used, based on known band profiles and strengths for the expected gas composition. Gas-dynamic effects are included and compressible and incompressible flows treated. Comparison is made with a simple, optically-thin calculation using radiation data of Hottel which gives results consistent with the average determined by the diffusion model. The radiation emission determines the gas cooling rate in the steam generator and, hence, the nitric oxide emission rate with stack gases. Results of a detailed gas-kinetic calculation based on two stage combustion show that for reasonable furnace size the NO emission rate is reduced below the corresponding EPA standard for coal combustion. 相似文献
8.
9.
Measurement of the extracellular volume of human melanoma xenografts by contrast enhanced magnetic resonance imaging 总被引:2,自引:0,他引:2
The magnitude of the extracellular volume fraction (ECV) of tumors is of importance for the transport of macromolecular therapeutic agents from the vessel wall to the tumor cells. The aim of this study was to develop a method for measurement of tumor ECV by contrast enhanced MRI. Tumors of two human amelanotic melanoma xenograft lines (A-07 and R-18) grown intradermally in Balb/c nu/nu mice were used as model system, and muscle tissue was used as control. The renal arteries of the mice were ligated prior to i.v. administration of Gd-DTPA, and an MRI protocol for calculating Gd-DTPA concentration in tissue was followed. ECV was calculated from the Gd-DTPA concentrations in the tissue and in a plasma sample. In muscle tissue, the concentration reached a constant level after 1 min and the ECV was calculated to be 0.12 (+/- 0.01), consistent with values reported in the literature. Individual tumors showed large differences in the uptake of Gd-DTPA. The Gd-DTPA concentration in the tissue at 40 min after the Gd-DTPA administration was used to calculate tumor ECV. The ECV was found to differ significantly among regions of individual tumors and among individual tumors. The ECV ranged from 0.075 to 0.33 for A-07 tumors and from 0.016 to 0.097 for R-18 tumors. The intra- and intertumor heterogeneity in ECV was confirmed by histologic findings, showing that contrast enhanced MRI is suitable for non-invasive studies of the ECV in experimental tumors without necrosis. 相似文献
1