首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   11篇
  免费   1篇
化学   5篇
力学   1篇
物理学   6篇
  2022年   2篇
  2013年   1篇
  2009年   1篇
  2005年   1篇
  2001年   1篇
  2000年   2篇
  1999年   2篇
  1993年   1篇
  1981年   1篇
排序方式: 共有12条查询结果,搜索用时 125 毫秒
1.
2.
Large enhancements have been observed in the sub-barrier fusion cross sections for Ti+Ni systems in our previous studies. Coupled channel calculations incorporating couplings to 2+ and 3 states failed to explain these enhancements completely. A possibilty of transfer channels contributing to the residual enhancements had been suggested. In order to investigate the role of relevant transfer channels, measurements of one- and two-nucleon transfer were carried out for 46,48Ti+61Ni systems. The present paper gives the results of these studies.  相似文献   
3.
Understanding the relation between spatial heterogeneity and structural rejuvenation is one of the hottest topics in the field of metallic glasses (MGs). In this work, molecular dynamics (MD) simulation is implemented to discover the effects of initial spatial heterogeneity on the level of rejuvenation in the Ni$_{80}$P$_{20 }$MGs. For this purpose, the samples are prepared with cooling rates of $10^{10}$ K/s-$10^{12}$ K/s to make glassy alloys with different atomic configurations. Firstly, it is found that the increase in the cooling rate leads the Gaussian-type shear modulus distribution to widen, indicating the aggregations in both elastically soft and hard regions. After the primary evaluations, the elastostatic loading is also used to transform structural rejuvenation into the atomic configurations. The results indicate that the sample with intermediate structural heterogeneity prepared with 10$^{11}$ K/s exhibits the maximum structural rejuvenation which is due to the fact that the atomic configuration in an intermediate structure contains more potential sites for generating the maximum atomic rearrangement and loosely packed regions under an external excitation. The features of atomic rearrangement and structural changes under the rejuvenation process are discussed in detail.  相似文献   
4.
A host-guest optical sensor for the determination of aliphatic amines as exemplified by octylamine is proposed. It is based on the reversible fluorescence enhancement of heptakis(2,6-di-O-isobutyl)-β-cyclodextrin(DOB-β-CD) hosting tetraphenylporphyrin (TPP) immobilized in poly(vinyl chloride) (PVC) membrane by aliphatic amine extracted from aqueous phase into membrane phase. The optimum membrane contained 1.15 wt % TPP, 6.15 wt % DOB-β-CD as sensing reagent and other membrane materials. The fluorescence enhancement of the membrane resulted from the formation of a stable three-component complex among DOB-β-CD, TPP, and aliphatic amines. With the optimum conditions described, the fluorescence response of the sensor to octylamine shows a good correlation with the theoretically derived equation in the range 1.0 × 10–6 to 8.0 × 10–4 mol/L. The response characteristics including reversibility, response time, reproducibility and lifetime and selectivity of this optical device are also discussed in detail. This sensor has also been applied for the determination of octylamine in water samples containing interferents with satisfactory recovery.  相似文献   
5.
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
6.
The effects on the radiation response of Harwell polymethylmethacrylate (PMMA) dosimeters of dose-rate, radiation type, temperature during irradiation and post-irradiation storage, and post-irradiation stability, are of importance to the operators of commercial irradiation facilities.

This paper describes recent studies of the effects of some of these parameters on the radiation response of Harwell Red 4034, Amber 3042, and Gammachrome YR Perspex dosimeters, and provides data on batch to batch variation and shelf-life.  相似文献   

7.
We designed a semiautomatic segmentation method to easily measure the volume of a bone cyst (simple or aneurysmal) from magnetic resonance imaging (MRI). This method only considers the fluid part of the cyst, even when there are several fluid intensities (fluid-fluid levels) or the cyst is multi-loculated. The nonhomogeneity phenomenon inherent in MRI was handled by a k-means clustering algorithm that classified all of the voxels corresponding to the cyst fluid as the same voxel intensity. Level-set segmentation was expanded into the whole cyst volume and the resulting segmented volume provided the measured cyst volume. The semiautomatic method was compared with the usual manual method (manual contour tracing) in terms of its ability to measure a known volume of water (gold standard) as well as the volume of 29 bone cysts. Both methods were equivalent with regards to the gold standard, but the semiautomatic method was more accurate. In terms of the experimental measurements, the semiautomatic method was more repeatable and reproducible, and less time-consuming and fastidious than the manual method. Our semiautomatic method uses only freeware and can be used routinely whenever measurement of a bone cyst volume is needed.  相似文献   
8.
We have detected the four 18 cm OH lines from the z approximaetely 0.765 gravitational lens toward PMN J0134-0931. The 1612 and 1720 MHz lines are in conjugate absorption and emission, providing a laboratory to test the evolution of fundamental constants over a large lookback time. We compare the HI and OH main line absorption redshifts of the different components in the z approximately 0.765 absorber and the z approximately 0.685 lens toward B0218 + 357 to place stringent constraints on changes in F triple-bond g(p)[alpha(2)/mu](1.57). We obtain [DeltaF/F] = (0.44 +/- 0.36(stat) +/- 1.0(sys)t) x 10(-5), consistent with no evolution over the redshift range 0 < z < or = 0.7. The measurements have a 2sigma sensitivity of [Deltaalpha/alpha] < 6.7 x 10(-6) or [Deltamu/mu] < 1.4 x 10(-5) to fractional changes in alpha and mu over a period of approximately 6.5 G yr, half the age of the Universe. These are among the most sensitive constraints on changes in mu.  相似文献   
9.
Portable infusion pumps are an interesting solution to continue outpatient parenteral antimicrobial therapy (OPAT) at the patient's home. However, the use of ceftazidime for such applications is challenging in view of its relatively poor stability in solution. In this study, elastomeric infusion pumps with 6 or 7 g of ceftazidime were deflated over 24 h in an oven at 33°C while ceftazidime and its degradation product, pyridine, were regularly monitored. Hereto, a fast and sensitive liquid chromatographic (LC) method has been developed using a Kinetex® C18 (150 × 3 mm, 2.6 μm) column with gradient elution. Ammonium formate 20 mM and acetonitrile (ACN) were mixed in a ratio of 98:2 v/v for mobile phase A and 85:15 v/v for mobile phase B. Both were adjusted to pH 4.5 with formic acid. The flow rate was set at 0.4 mL/min. The solution with a starting dose of 6 g ceftazidime was found to be degraded 10% after an average of 19 h 11 min so that an administration of 6 g to the patient was not reached. For the solution with a starting dose of 7 g of ceftazidime, 10% degradation was observed after an average of 18 h 42 min. However, by starting from a higher dose, an average of 6.56 g of ceftazidime could be administered over 24 h. In addition, 1.0% of pyridine versus ceftazidime pentahydrate with sodium carbonate (=mixture for injection) was formed over 24 h.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号