排序方式: 共有21条查询结果,搜索用时 218 毫秒
1.
2.
A gas-chromatographic analyzer allowing the selective detection of individual oxygenates in complex organic mixtures, such as gasolines, is described. The analyzer is based on the oxygen-specific response flame ionization detection (O-FID) method. The system operates with capillary columns and includes a cracking reactor to convert any oxygenate to carbon monoxide and a special FID equipped with a microreactor for the catalytic hydro-genation of CO and detection as methane. Hydrocarbons give no signal. The selectivity of the method is better than 1:107 and the linear range approaches 105. The analysis of modern fuels containing oxygenated additives, to improve octane ratings, may greatly benefit from the proposed analytical method. 相似文献
3.
Adamson P Auty DJ Ayres DS Backhouse C Barr G Bishai M Blake A Bock GJ Boehnlein DJ Bogert D Cavanaugh S Cherdack D Childress S Coelho JA Coleman SJ Corwin L Cronin-Hennessy D Danko IZ de Jong JK Devenish NE Diwan MV Dorman M Escobar CO Evans JJ Falk E Feldman GJ Frohne MV Gallagher HR Gomes RA Goodman MC Gouffon P Graf N Gran R Grant N Grzelak K Habig A Harris D Hartnell J Hatcher R Himmel A Holin A Huang X Hylen J Ilic J Irwin GM Isvan Z Jaffe DE James C Jensen D Kafka T Kasahara SM Koizumi G 《Physical review letters》2011,107(1):011802
Results are reported from a search for active to sterile neutrino oscillations in the MINOS long-baseline experiment, based on the observation of neutral-current neutrino interactions, from an exposure to the NuMI neutrino beam of 7.07×10(20) protons on target. A total of 802 neutral-current event candidates is observed in the Far Detector, compared to an expected number of 754 ± 28(stat) ± 37(syst) for oscillations among three active flavors. The fraction f(s) of disappearing ν(μ) that may transition to ν(s) is found to be less than 22% at the 90% C.L. 相似文献
4.
Adamson P Andreopoulos C Armstrong R Auty DJ Ayres DS Backhouse C Barr G Bishai M Blake A Bock GJ Boehnlein DJ Bogert D Cavanaugh S Cherdack D Childress S Choudhary BC Coelho JA Coleman SJ Corwin L Cronin-Hennessy D Danko IZ de Jong JK Devenish NE Diwan MV Dorman M Escobar CO Evans JJ Falk E Feldman GJ Frohne MV Gallagher HR Gomes RA Goodman MC Gouffon P Graf N Gran R Grant N Grzelak K Habig A Harris D Hartnell J Hatcher R Himmel A Holin A Huang X Hylen J Ilic J Irwin GM Isvan Z Jaffe DE 《Physical review letters》2011,106(18):181801
Measurements of neutrino oscillations using the disappearance of muon neutrinos from the Fermilab NuMI neutrino beam as observed by the two MINOS detectors are reported. New analysis methods have been applied to an enlarged data sample from an exposure of 7.25×10(20) protons on target. A fit to neutrino oscillations yields values of |Δm(2)|=(2.32(-0.08)(+0.12))×10(-3) eV(2) for the atmospheric mass splitting and sin(2)(2θ)>0.90 (90% C.L.) for the mixing angle. Pure neutrino decay and quantum decoherence hypotheses are excluded at 7 and 9 standard deviations, respectively. 相似文献
5.
Adamson P Andreopoulos C Arms KE Armstrong R Auty DJ Ayres DS Baller B Barr G Barrett WL Becker BR Belias A Bernstein RH Bhattacharya D Bishai M Blake A Bock GJ Boehm J Boehnlein DJ Bogert D Bower C Buckley-Geer E Cavanaugh S Chapman JD Cherdack D Childress S Choudhary BC Coleman SJ Culling AJ de Jong JK Diwan MV Dorman M Dytman SA Escobar CO Evans JJ Falk Harris E Feldman GJ Frohne MV Gallagher HR Goodman MC Gouffon P Gran R Grashorn EW Grossman N Grzelak K Habig A Harris D Harris PG 《Physical review letters》2008,101(15):151601
A search for a sidereal modulation in the MINOS near detector neutrino data was performed. If present, this signature could be a consequence of Lorentz and CPT violation as predicted by the effective field theory called the standard-model extension. No evidence for a sidereal signal in the data set was found, implying that there is no significant change in neutrino propagation that depends on the direction of the neutrino beam in a sun-centered inertial frame. Upper limits on the magnitudes of the Lorentz and CPT violating terms in the standard-model extension lie between 10(-4) and 10(-2) of the maximum expected, assuming a suppression of these signatures by a factor of 10(-17). 相似文献
6.
EP Sheretov VS Gurov MV Dubkov OV Korneeva 《Rapid communications in mass spectrometry : RCM》1999,13(16):1699-1702
In this article we compare the classical monopole mass filter of von Zahn and the monopole mass filter with a hyperbolic V-shaped electrode. The experimental results and those of computer simulation for both mass spectrometers are presented. We show that the replacement of a conventional 90 degrees V-shaped electrode by an electrode with a hyperbolic profile substantially improves the peak shape of any given mass, and increases the mass resolution by a factor of 3-4 and the abundance sensitivity by a factor of 100. The potential of high analytical performance combined with electroforming techniques for electrode manufacture indicate future practical uses of such instruments. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
7.
8.
9.
J. C. Frohne 《Analytical and bioanalytical chemistry》1969,245(1-2):45-48
A semi-automatic procedure is described for measuring the melt-flow index of thermoplastic material. The piston rate, expressed as a sequence of pulses, is taken as a measure for the extrusion rate. The melt-flow index is indicated digitally and registered. In addition to routine melt-flow index determinations, the device allows investigations of the flow behaviour of plastic melts as a function of time as well as of viscoelastic phenomena. Examples are given to illustrate advantages and uses of the device. 相似文献
10.