This paper outlines the properties of rate-independent hysteresis and shows that the calculation of the free response of a single-degree-of-freedom (SDOF) mass-hysteresis-spring system is amenable to an exact solution. The more important issue of forced response is not so, requiring other methods of treatment. We consider the approximate describing function method and compare its results with exact numerical simulations. Agreement is good for small excitation amplitudes, where the system approximates to a linear mass-spring-damper system, and for very large amplitudes, where some sort of mass-line is approached. Intermediate values however, show high sensitivity to amplitude variations, and no regular solution is obtained by either approach. This appears thus to be an inherent property of the system pointing to the need for developing further analysis methods. 相似文献