1.
We propose that domain inversion can be directly induced by femtosecond laser both theoretically and experimentally, which opens a path to achieve three-dimensional (3D) nonlinear crystal with a period in sub-micron-scale. A simulation of domain inversion is modeled by considering the temporal distribution of femtosecond pulses. The calculation results clarify that the domain inversions can happen within or after the interaction with the laser pulse, and the response time of domain inversion is in the picosecond level depending on the intensity and the materials. The domain reversal windows of lithium niobate by femtosecond laser are observed which agrees with theoretical predictions qualitatively.  相似文献   
2.
为了测量EAST磁体位移的变化,采用计算机视觉处理方法构筑三维测量模型,利用边缘检测算法对图像采集系统获得的图片进行识别和检测,最终得出位移的变化值,从而可以在等离子体磁场位形控制中通过补偿修正这些变化。该测量方法解决了EAST装置冷质磁体位移测量的难题。  相似文献   
3.
为把电流引线罐从EAST 大厅移到离装置约30m 外的电源大厅,重新设计和制造了连接新旧超导导体间的13 对超导接头。介绍了其中1 对超导接头的结构设计、空隙率的确定、理论直流电阻计算、压降计算和加工装配方案等。为此,制造了1 对超导接头,并进行通电测试,结果表明,所设计的超导接头结构和加工工艺满足EAST 工程的要求。  相似文献   
4.
EAST装置超导母线电流传输线的核心部件是13对Nb Ti材料CICCs,其作用是连接超导磁体系统和高温超导电流引线,为磁体系统的运行提供馈电通道和失超状态下能量的释放通道。超导母线的稳定性直接影响了电流传输线运行的可靠性,同时还关系到超导磁体系统的安全性,需要对其进行严谨的研究。为了研究EAST新超导母线的稳定性,分别利用数学模型和GANDALF程序对超导母线的温度裕度和能量裕度进行了计算分析。计算结果表明由于超导母线的背景磁场很小,因此其稳定性要远高于超导磁体线圈的。该文的结果将为EAST新超导母线的运行提供参考。  相似文献   