首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   5篇
  免费   1篇
化学   2篇
数学   2篇
物理学   2篇
  2021年   1篇
  2009年   1篇
  2008年   2篇
  2007年   1篇
  2002年   1篇
排序方式: 共有6条查询结果,搜索用时 625 毫秒
1
1.
BIT Numerical Mathematics - Linear and nonlinear evolution equations have been formulated to address problems in various fields of science and technology. Recently, methods using an exponential...  相似文献   
2.
Dehydro[12]- and -[18]annulenes 3 and 4 fused with tetrafluorobenzene were newly synthesized by the copper-mediated oxidative coupling of 1,2-diethynyltetrafluorobenzene. The UV-vis spectra of 3 and 4 showed the maximum absorption to be almost identical to that of the corresponding unsubstituted benzodehydro[12]- and -[18]annulenes 1 and 2, respectively, while the reduction waves in cyclic voltammetry observed at potentials of -1.48 and -1.56 V vs Fc/Fc(+) for 3 and 4 were less negative than those for 1 and 2. In agreement with these results, theoretical calculations (B3LYP/6-31G(d)) indicated that the HOMO-LUMO gap is similar for 1 and 3 and for 2 and 4 but that the LUMO levels of 3 and 4 are apparently lowered by the electronegative fluorine substituents. The X-ray crystallography of single crystals grown from 3 (crystal A), 3.C(6)H(6) (crystal B), and a mixture of 1 and 3 (crystal C) demonstrated that the molecules of 3 are stacked in a slanted manner in crystals A and B, while those of 1 and 3 form sandwichlike 1:2 complexes (3.1.3) that are stacked in a columnar arrangement in crystal C. Despite the suitable packing for topochemical polymerization, crystals A-C were quite stable against photochemical reaction. In contrast, differential scanning calorimetry showed that the thermal polymerization occurred explosively at 120-135 degrees C.  相似文献   
3.
We investigated X-ray energy distribution in an X-ray microbeam produced by a polycapillary X-ray lens in combination with a sealed-type X-ray tube. This polycapillary X-ray lens has an output focal distance (OFD) of approximately 15 mm. The size of the X-ray microbeam and its OFD were estimated by using a wire scanning method. In our case, the sizes of the X-ray microbeams at the output focal distance were 49 microm for Mo L(alpha), 36 microm for W L(alpha), and 28 microm for Mo K(alpha). The spot sizes depend on the energy of the X-ray fluorescence. The reason for the energy dependence is that X-ray capillary optics is based on the principle of propagation through glass capillaries by means of X-ray total external reflection. The evaluated OFD values of Mo L(alpha) and Mo K(alpha) were slightly changed in 17 microm. However, a deviation of 100 microm from the OFD caused only a 3% increase of the focal spot size. Therefore, we concluded that the OFD showed no significant dependence on X-ray energy.  相似文献   
4.
An improvement of spatial resolution of µ‐XRF by using a thin metal filter was investigated. The size of the x‐ray beam focused by the polycapillary x‐ray lens depended on the energy of the characteristic x‐rays. Original spot sizes at the focal point were 48 µm for CrKα, 41 µm for NiKα, and 28 µm for MoKα, respectively. To make the x‐ray beam size small, Ti? Cu thin foil was placed between the output of the lens and the focal point as a metal filter to reduce the continuous x‐rays. Finally, the x‐ray microbeam size was improved to 30 µm by applying a filter. Clear 2D mapping images of Cr, Fe, and Ni in 300‐mesh stainless steel could be obtained by applying this filter. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   
5.
In this paper, we are presenting a proposal for new modified algorithms for RRGMRES and AGMRES. It is known that RRGMRES and AGMRES are viable methods for solving linear discrete ill-posed problems. In this paper we have focused on the residual norm and have come up with two improvements where successive updates and the stabilization of decreases for the residual norm improve performance respectively. Our numerical experiments confirm that our improved algorithms are effective for linear discrete ill-posed problems.  相似文献   
6.
In this paper, we propose a new implementation of the Newton scheme of an approximate preconditioner for the reduced linear system. In the original Newton scheme, the trouble is that the computation cost of the matrix–matrix product is always so expensive. On the other hand, the proposed implementation computes the preconditioner implicitly and reduces the cost of constructing the preconditioner by using the matrix–vector product form. We also show that the proposed implementation is less expensive than computing the preconditioner in explicit form.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号