排序方式: 共有3条查询结果,搜索用时 0 毫秒
1
1.
A reversed flow injection colorimetric procedure for determining iron(III) at the μg level was proposed. It is based on the reaction between iron(III) with norfloxacin (NRF) in 0.07 mol l−1 ammonium sulfate solution, resulting in an intense yellow complex with a suitable absorption at 435 nm. Optimum conditions for determining iron(III) were investigated by univariate method. The method involved injection of a 150 μl of 0.04% w/v colorimetric reagent solution into a merged streams of sample and/or standard solution containing iron(III) and 0.07 mol l−1 ammonium sulfate in sulfuric acid (pH 3.5) solution which was then passed through a single bead string reactor. Subsequently the absorbance as peak height was monitored at 435 nm. Beer's law obeyed over the range of 0.2–1.4 μg ml−1 iron(III). The method has been applied to the determination of total iron in water samples digested with HNO3–H2O2 (1:9 v/v). Detection limit (3σ) was 0.01 μg ml−1 the sample through of 86 h−1 and the coefficient of variation of 1.77% (n=12) for 1 μg ml−1 Fe(III) were achieved with the recovery of the spiked Fe(III) of 92.6–99.8%. 相似文献
2.
Chutima Septhum Jody Morgan Larry Hick John B Bremner Saowanee Rattanaphani Vichitr Rattanaphani 《Analytical sciences》2007,23(10):1209-1214
The Al(III) and Ga(III) complexes formed by morin (M) in aqueous solution were investigated by means of electrospray ionization mass spectrometry (ESI-MS). In the full scan mass spectra, Al:M showed 1:2 and 2:3 stoichiometric ratios. When (S)-N-acetylserine methyl ester (Ser), as a partial mimic of the serine residue in silk, was added to Al:M and Ga:M complexes in aqueous solution, the mass spectra of Ser:Al:M showed 1:1:1 and 1:1:2 stoichiometric ratios. The patterns of the mass spectra of Ga:M and Ser:Ga:M complexes were similar to those for the corresponding Al(III) complexes. Calculated heats of formation of potential structures of the complexes, with and without bound water, were obtained using semiempirical PM3 calculations. 相似文献
3.
B Purachat S Liawruangrath P Sooksamiti S Rattanaphani D Buddhasukh 《Analytical sciences》2001,17(3):443-447
A simple colorimetric flow-injection system for the determination of Cu(II) based on a complexation reaction with nitroso-R salt is described. The chemical and FIA variables were established using the univariate and simplex methods. A small volume of Cu(II) was mixed with merged streams of nitroso-R salt and acetate buffer solutions. The absorbance of the complex was continuously monitored at 492 nm. The calibration curve over the concentration range 1.0-7.0 microg ml(-1) was obtained. The relative standard deviation for determining 4.0 microg ml(-1) Cu(II) was 0.47% (n = 11). The detection limit (3sigma) was 0.68 microg ml(-1) and the sample throughput was 150 h(-1). The validity of the method has been satisfactorily examined for the determination of Cu(II) in wastewater and copper ore samples. The accuracy was found to be high, because the student t-values were calculated to be less than the theoretical values when the results were compared with those obtained by FAAS. 相似文献
1