首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   16篇
  免费   0篇
化学   11篇
数学   1篇
物理学   4篇
  2008年   1篇
  2003年   1篇
  2002年   1篇
  2001年   1篇
  1999年   1篇
  1998年   1篇
  1994年   1篇
  1993年   2篇
  1991年   1篇
  1990年   2篇
  1989年   1篇
  1980年   2篇
  1979年   1篇
排序方式: 共有16条查询结果,搜索用时 218 毫秒
1.
Heavy ion irradiation in the electronic stopping power region induces macroscopic dimensional change in metallic glasses and introduces magnetic anisotropy in some magnetic materials. The present work is on the irradiation study of ferromagnetic metallic glasses, where both dimensional change and modification of magnetic anisotropy are expected. Magnetic anisotropy was measured using Mössbauer spectroscopy of virgin and irradiated Fe40Ni40B20 and Fe40Ni38Mo4B18 metallic glass ribbons. 90 MeV 127I beam was used for the irradiations. Irradiation doses were 5×1013 and 7.5×1013 ions/cm2. The relative intensity ratios D 23 of the second and third lines of the Mössbauer spectra were measured to determine the magnetic anisotropy. The virgin samples of both the materials display in-plane magnetic anisotropy, i.e., the spins are oriented parallel to the ribbon plane. Irradiation is found to cause reduction in magnetic anisotropy. Near-complete randomization of magnetic moments is observed at high irradiation doses. Correlation is found between the residual stresses introduced by ion irradiation and the change in magnetic anisotropy.  相似文献   
2.
DC Jana  SS Pradhan 《Pramana》2001,56(1):107-115
In subnormal glow discharge under d.c. excitation at different pressure in a varying transverse magnetic field (0 to 30 G) some measurements have been carried out for various initial average tube currents. The voltage across the discharge increases and average tube current and residual current decreases in the magnetic field. With the help of Beckman’s expression [4] for the axial field and the electron density distribution in a transverse magnetic field the observed variation of current and voltage can be satisfactorily explained. The variation of axial electric field with transverse magnetic field can be represented to a fair degree of accuracy by the derived equation. The behaviour of residual current with magnetic field has been observed in these oscillations.  相似文献   
3.
4.
Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS) has been used to determine the mass of a double-stranded 500 base-pair (bp) polymerase chain reaction (PCR) product with an average theoretical mass of the blunt-ended (i.e. unadenylated) species of 308 859.35 Da. The PCR product was generated from the linearized bacteriophage Lambda genome which is a double-stranded template. Utilization of ethanol precipitation in tandem with a rapid microdialysis step to purify and desalt the PCR product was crucial to obtain a precise mass measurement. The PCR product (0.8 pmol/μL) was electrosprayed from a solution containing 75% acetonitrile, 25 mM piperidine, and 25 mM imidazole and was infused at a rate of 200 nL/min. The average molecular mass and the corresponding precision were determined using the charge-states ranging from 172 to 235 net negative charges. The experimental mass and corresponding precision (reported as the 95% confidence interval of the mean) was 309 406 +/- 27 Da (87 ppm). The mass accuracy was compromised due to the fact that the PCR generates multiple products when using Taq polymerase due to the non-template directed 3'-adenylation. This results in a mixture of three PCR products with nearly identical mass (i.e. blunt-ended, mono-adenylated and di-adenylated) with unknown relative abundances that were not resolved in the spectrum. Thus, the experimental mass will be a weighted average of the three species which, under our experimental conditions, reflects a nearly equal concentration of the mono- and di-adenylated species. This report demonstrates that precise mass measurements of PCR products up to 309 kDa (500 bp) can be routinely obtained by ESI-FTICR requiring low femtomole amounts. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
5.
6.
Koebele AR  Tilotta DC 《Talanta》1993,40(2):247-254
A Fourier transform spectrometer is used to record the infrared emission from chlorinated hydrocarbons combusted in an air/acetylene flame. In this manner, the chlorinated hydrocarbons are determined by monitoring the infrared emission of hydrogen chloride at 2653 cm(-1). Discussion is presented of the air/acetylene flame background, and the potential spectral interference from the emission of deuterated species. Practical detection limits for chloroform, carbon tetrachloride and methylene chloride in acetone, methanol, and ethanol are solvent independent and are found to be 1.1, 0.80, and 1.0%, respectively. Calibration curves for these three analytes are linear from their detection limits to approximately 55% (v/v). In addition, evidence is presented that flame flicker-noise does not lead to a multiplex disadvantage when the Fourier transform instrument is used for data acquisition.  相似文献   
7.
The use of ion chromatography with continuous UV detection for radiochemical separation of Cr with simultaneous yield determination is presented. The RNAA method consists of sample destruction in HNO3+HClO4, extraction of Cr(VI) with tribenzylamine in CHCl3, backextraction in NaOH and chromatography of chromate. From radiotracer experiments, the ratio of signals for51Cr and Cr spike was found to be constant for a chromium mass range of 15 to 100 g. Application of the RNAA method to Cr determination in biological reference materials showed a reasonable agreement with the reference values. A relative standard deviation of 3% on the 100 g/kg level for homogeneous material was achieved.IAEA-fellow, on leave from the Philippine Nuclear Research Institute Philippine  相似文献   
8.
The pyrolysis process of chromated copper arsenate-treated wood impregnated with phosphoric acid (2–6 wt.%) has been investigated using a Kugelrohr short-path distillation apparatus. The presence of phosphoric acid is shown to change the overall pyrolysis kinetics and yields of products resulting in a decrease in the amount of volatile products and an increase in the char formation. The yield of levoglucosan was found to decrease in the presence of relatively higher concentrations of phosphoric acid, while the yield of levoglucosenone increased. The pyrolysis of chromated copper arsenate-treated wood in the presence of phosphoric acid gave rise to 22% (on water-free tar basis) levoglucosenone. Such data demonstrates the potential for a new pathway toward the rational utilization of chromated copper arsenate-treated wood waste.  相似文献   
9.
Kubala SW  Tilotta DC  Busch MA  Busch KW 《Talanta》1991,38(6):589-602
The feasibility of determining chlorinated, purgeable organic compounds (POCs) in aqueous samples by flame infrared-emission (FIRE) spectrometry was evaluated with a specially designed, multichannel, dispersive spectrometer having sufficient resolving power to prevent interference from large amounts of non-halogenated POCs that could also be present in the sample. The polychromator was based on a Czerny-Turner optical mounting with a 0.15-m focal length, a nominal focal ratio of f/3, and a reciprocal linear dispersion of 0.15 mum/mm in the first order. The HCl and CO(2) infrared emission bands (3.77 and 4.42 mum, respectively) were monitored in two analytical channels, while a third reference channel, used for background subtraction, monitored the H(2)O background emission at 2.8 mum. Instrumental performance was evaluated with dichloromethane, trichloromethane, trichloroethylene, 1,1,2,2-tetrachloroethane and monochlorobenzene as test compounds, and parameters such as the linear dynamic range, reproducibility, detection limit and signal-to-noise ratio, and extent of spectral crosstalk between channels were determined. The feasibility of performing a quantitative analysis of a two-component mixture of dichloromethane and trichloromethane at trace levels was demonstrated.  相似文献   
10.
Tilotta DC  Fry RC  Fateley WG 《Talanta》1990,37(1):53-60
A liquid-crystal spatial light-modulator Hadamard transform spectrometer is adapted for multielemental atomic spectrochemical analysis. The flame emissions of alkali metals are studied as a preliminary example. The multiplex disadvantage normally plaguing application of Hadamard and Fourier transform methods to atomic analysis is circumvented. Permanent electro-optic "closure" of certain Hadamard mask slits (corresponding to intense major element emissions) improves the signal-to-noise ratio (SNR) of the remaining trace element emissions. This approach to SNR enhancement of weaker spectral features by blocking known intense features is called the selective multiplex advantage. A problem with the contrast ratio (relative transmissions of the transparent and opaque states) of the liquid-crystal Hadamard mask has been identified in terms of "optical leakage". This produces an offset in the Hadamard encodegram, and leads to concentration-dependent baseline-offset effects in the transformed spectrum. A mathematical correction procedure was devised and evaluated experimentally.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号