首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   3篇
  免费   0篇
化学   3篇
  2019年   1篇
  2004年   1篇
  2001年   1篇
排序方式: 共有3条查询结果,搜索用时 296 毫秒
1
1.
2.
JPC – Journal of Planar Chromatography – Modern TLC - This report describes the TLC separation of two classes of chiral drug, including β-blocking drugs and non-steroidal...  相似文献   
3.
This work shows developing conductometric sensor based on molecularly imprinted polymer (MIP) for the screening of complex mixture of haloacetic acids (HAAs) in drinking water. The recognition of the HAAs was achieved by trichloroacetic acid (TCAA)-imprinted polymers synthesised from the copolymerization of 4-vinylpyridine (4-VPD) and ethylene glycol dimethacrylate (EDMA) in the presence of the TCAA template in acetonitrile, either by bulk polymerization (BP) method or by a multi-step swelling polymerization (MSP) method. TCAA-imprinted polymer of both methods was tested for re-binding with the template and its analogs. It was found that these polymers could bind selectively to the template molecule and HAA derivatives. HAA measurements were carried out by the application of the polyvinyl chloride membrane fabricated with TCAA-imprinted polymer on conductometric sensors. The technological parameters (operating frequency, membrane composition, ionic strength and medium pH) for the sensors were identified and optimised in respect to the response to TCAA, using sensor fabricating with BP-based MIP as a model. The selectivity of the sensors constructed with MIPs made by either that of the two imprinting methods was also investigated, which the influence of the method of imprinting on the binding strength and selectivity of the recognition element embedded in sensor was observed. The sensors showed high sensitivity and selectivity for the response toward TCAA, the sensor modified with MSP-based MIP being better. In addition, the sensors, particularly when was constructed with MSP-based MIP exhibited good cross-reactivities with a wide range of HAAs, which is useful for the screening of the group of HAA usually present in chlorinated water in complex mixtures. Thus, the sensor modified with MSP-based MIP was chosen for analytical application. The calibration of this sensor was determined, showing the good linear graphs (R2>0.970) for HAAs over the concentration range of 25-1000 μg/l and the detection limit of each HAA in the range 0.2-5.0 μg/l. Moreover, the results in real analysis of the sensor indicate the simplicity and reliability of the method. The present work demonstrated that the sensor based on TCAA-imprinted polymer is a fast and sensitive screening method of HAAs in drinking water.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号