首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   20篇
  免费   0篇
化学   19篇
物理学   1篇
  2019年   2篇
  2017年   1篇
  2016年   1篇
  2013年   4篇
  2012年   2篇
  2011年   1篇
  2010年   2篇
  2006年   1篇
  2005年   3篇
  2004年   2篇
  2003年   1篇
排序方式: 共有20条查询结果,搜索用时 15 毫秒
1.
2.
Comprehensive analysis of high-resolution mass spectra of aged natural dammar resin obtained with Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR-MS) using matrix-assisted laser desorption/ionization (MALDI) and atmospheric pressure chemical ionization (APCI) is presented. Dammar resin is one of the most important components of painting varnishes. Dammar resin is a terpenoid resin (dominated by triterpenoids) with intrinsically very complex composition. This complexity further increases with aging. Ten different solvents and two-component solvent mixtures were tested for sample preparation. The most suitable solvent mixtures for the MALDI-FT-ICR-MS analysis were dichloromethane-acetone and dichloromethane-ethanol. The obtained MALDI-FTMS mass spectrum contains nine clusters of peaks in the m/z range of 420-2200, and the obtained APCI-FTMS mass spectrum contains three clusters of peaks in the m/z range of 380-910. The peaks in the clusters correspond to the oxygenated derivatives of terpenoids differing by the number of C(15)H(24) units. The clusters, in turn, are composed of subclusters differing by the number of oxygen atoms in the molecules. Thorough analysis and identification of the components (or groups of components) by their accurate m/z ratios was carried out, and molecular formulas (elemental compositions) of all major peaks in the MALDI-FTMS and APCI-FTMS spectra were identified (and groups of possible isomeric compounds were proposed). In the MALDI-FTMS and APCI-FTMS mass spectrum, besides the oxidized C(30), triterpenoids also peaks corresponding to C(29) and C(31) derivatives of triterpenoids (demethylated and methylated, correspondingly) were detected. MALDI and APCI are complementary ionization sources for the analysis of natural dammar resin. In the MALDI source, preferably polar (extensively oxidized) components of the resin are ionized (mostly as Na(+) adducts), whereas in the APCI source, preferably nonpolar (hydrocarbon and slightly oxidized) compounds are ionized (by protonation). Either of the two ionization methods, when used alone, gives an incomplete picture of the dammar resin composition.  相似文献   
3.
A high-performance thin-layer chromatography (HPTLC) method was developed for fast evaluation of the purity of solid-phase synthesis products. The results obtained were in good agreement with results obtained by the LC-MS method (r(2) = 0.8404) or by the LC-UV method (r(2) = 0.8053), confirming the suitability of HPTLC for purity analysis of combinatorial syntheses. The synthesis products can be quantified and identified by measuring UV densitograms or in situ UV spectra or by ESI-MS after isolation of the zone of interest. A new, simple, and fast method for transferring the zone of the analyte from the plate to the ESI-MS equipment is described. The new HPTLC method enables rapid and efficient analysis of approximately 40 samples in parallel. As such, it offers a cheaper and easier way to analyze the purity of synthesis products than the commonly used LC-UV-MS.  相似文献   
4.
The influence of a variety of counteranions on the properties of polyelectrolyte multilayers deposited by layer-by-layer technique is studied by using ellipsometry and AFM. We found out that in thin dry multilayers (20-90 nm) ofpoly(4-styrenesulfonate) (PSS) and poly(diallyldimethylammonium) (PDADMA), the thickness follows reasonably well the position of the counteranion in the Hofmeister series. The polyelectrolyte-counteranion interaction is studied by means of viscosity measurements of semidilute solutions of PDADMA in the presence of different anions. The dynamic viscosities follow the Hofmeister series of anions and correlate with the thickness of multilayers. Two parameters describing the interaction of ions with water, the Jones-Dole viscosity B coefficient and the hydration entropy, are used to explain the anion effect on the developing multilayer thickness. Reasonably smooth and monotonic functional dependence is observed between the layer thickness and these two parameters.  相似文献   
5.
The activity coefficients at infinite dilution (γ) of dimethylsulphide (DMS) in four hydrocarbon solvents were measured using the dilutor technique at temperatures between 288 K and 303 K. The four hydrocarbons were hexane, 1-hexene, 2,2,4-trimethylpentane and 2,4,4-trimethyl-1-pentene. The dilutor technique is based on the stripping of the highly diluted solute, i.e. DMS, by a constant flow of inert gas. The gas composition was analysed by gas chromatography and the rate of solute removal was calculated from the area of the peaks.  相似文献   
6.
Eight racemic 1-(furan-2-yl)ethanols were prepared from the corresponding carbonyl compounds for enantioselective acylation studies, and seven of them were used in preparative-scale kinetic resolutions with Candida antarctica lipase B (Novozym 435) and vinyl acetate in dried diisopropyl ether. Mechanism-based competition between the (R)-acetate (enzymatic acylation product), vinyl acetate (added acylating reagent), and acetic acid (enzymatic hydrolysis product) toward CAL-B, together with the residual water of the lipase were shown to be potential reasons for side reactions, which affected the course of the kinetic resolution of 1-[5-(2-chlorophenyl) and (4-bromophenyl)furan-2-yl]ethanols. Clear effects were not observed with the other alcoholic substrates. Alcoholysis of the enantiomerically enriched (R)-acetates with methanol and CAL-B in diisopropyl ether was shown to be a potential method for the deprotection of the (R)-acetates and the formation of (R)-alcohols.  相似文献   
7.
The feasibility of ultra thin-layer chromatography atmospheric pressure matrix-assisted laser desorption ionization mass spectrometry (UTLC-AP-MALDI-MS) has been studied in the analysis of small molecules. Because of a thinner adsorbent layer, the monolithic UTLC plates provide 10-100 times better sensitivity in MALDI analysis than conventional high performance thin-layer chromatography (HPTLC) plates. The limits of detection down to a low picomole range are demonstrated by UTLC-AP-MALDI-MS. Other advantages of UTLC over HPTLC include faster separations and lower solvent consumption. The performances of AP-MALDI-MS and vacuum MALDI-MS have been compared in the analysis of small drug molecules directly from the UTLC plates. The desorption from the irregular surface of UTLC plates with an external AP-MALDI ion source combined with an ion trap instrument provides clearly less variation in measurements of m/z values when compared with a vacuum MALDI-time-of-flight (TOF) instrument. The performance of the UTLC-AP-MALDI-MS method has been applied successfully to the purity analysis of synthesis products produced by solid-phase parallel synthesis method.  相似文献   
8.
Ionization efficiency and mechanism in ESI is strongly affected by the properties of mobile phase. The use of mobile-phase properties to accurately describe droplets in ESI source is convenient but may be inadequate as the composition of the droplets is changing in the plume due to electrochemical reactions occurring in the needle tip as well as continuous drying and fission of droplets. Presently, there is paucity of research on the effect of the polarity of the ESI mode on mobile phase composition in the droplets. In this paper, the change in the organic solvent content, pH, and droplet size are studied in the ESI plume in both ESI+ and ESI– ionization mode. We introduce a rigorous way – the absolute pH (pHabs H 2 O) – to describe pH change in the plume that takes into account organic solvent content in the mobile phase. pHabs H 2 O enables comparing acidities of ESI droplets with different organic solvent contents. The results are surprisingly similar for both ionization modes, indicating that the dynamics of the change of mobile-phase properties is independent from the ESI mode used. This allows us to conclude that the evolution of ESI droplets first of all proceeds via the evaporation of the organic modifier and to a lesser extent via fission of smaller droplets from parent droplets. Secondly, our study shows that qualitative findings related to the ESI process obtained on the ESI+ mode can almost directly be applied also in the ESI– mode.
Graphical Abstract ?
  相似文献   
9.
Resin acids are considered to be significant contributors to the toxicity of pulp mill effluents. Traditionally, the analysis of these acids is performed by liquid–liquid extraction followed by gas chromatography. This paper describes a method suitable for monitoring the relative concentration levels of the main resin acid component, dehydroabietic acid (DHAA), in process waters by atmospheric pressure chemical ionisation-mass spectrometry (APCI-MS). This method was further improved, first by testing different precolumns for on-line sample clean-up and then by developing the APCI-MS analysis of the analytes trapped in the precolumn (i.e., solid-phase extraction column). The external standard, internal standard, and response factor methods were compared. The curve profiles of the results obtained with the above determinations were very similar to each other. This finding suggested that the rapid APCI-MS method, using a selected ion monitoring (SIM) technique, is a potential tool for monitoring relative concentration levels of DHAA. The technique is also recommended for rapid and simple monitoring of DHAA as well as of other resin acids, and their derivatives, such as their chlorinated analogues, in various aquatic environmental samples.  相似文献   
10.
Atmospheric particles were collected with a high-volume sampling system at an urban site in Helsinki (Finland). The samples were analysed by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry (SFE-LC-GC-MS). The aerosol sample was first extracted by SFE. The extract was then transferred to a liquid chromatograph where it was fractionated into four fractions according to polarity. Each fraction from the liquid chromatograph was transferred to a gas chromatograph by large-volume injection, where final separation was carried out. The first LC fraction (280 microl) contained nonpolar compounds, such as n-alkanes, hopanes and steranes. The second fraction (840 microl) included polycyclic aromatic hydrocarbons (PAHs) and alkyl-PAHs, while the third and fourth fractions (840 microl each) contained more polar compounds, such as n-alkan-2-ones, n-alkanals, oxy-PAHs and quinones.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号