排序方式: 共有9条查询结果,搜索用时 377 毫秒
1
1.
Millea KM Kass IJ Cohen SA Krull IS Gebler JC Berger SJ 《Journal of chromatography. A》2005,1079(1-2):287-298
The performance characteristics of multidimensional liquid chromatographic protein separations were evaluated using on-line electrospray mass detection, and a novel workflow for automated LC/MS data processing. Two-dimensional ion exchange/reversed-phase LC separations of Escherichia coli cytosol were conducted using either a continuous linear or discontinuous step gradient in the first dimension. Chromatographic profiles of the top 100 most abundant components were characterized to assess overall separation reproducibility within each mode, and to characterize differences in component distribution between the two modes of operation. Analysis of the resulting data indicates that multidimensional separations of complex protein mixtures can be done reproducibly. Furthermore, under the conditions employed within this study, a linear first dimension gradient was more effective at fractionating the protein mixture, distributing fewer major components to multiple second dimension cycles than an equivalent step gradient. The application of on line mass spectrometry, and automated processing of the resulting data, proved valuable for producing component level analysis of multidimensional protein separations. 相似文献
2.
KM Varier AM Vinodkumar NVSV Prasad PV Madhusudhana Rao DL Sastry Lagy T Baby MC Radhakrishna NG Puttaswamy JJ Das P Sugathan N Madhavan AK Sinha DO Kataria 《Pramana》1999,53(3):529-533
Large enhancements have been observed in the sub-barrier fusion cross sections for Ti+Ni systems in our previous studies.
Coupled channel calculations incorporating couplings to 2+ and 3− states failed to explain these enhancements completely. A possibilty of transfer channels contributing to the residual enhancements
had been suggested. In order to investigate the role of relevant transfer channels, measurements of one- and two-nucleon transfer
were carried out for 46,48Ti+61Ni systems. The present paper gives the results of these studies. 相似文献
3.
Tzu-Chia Chen Mahyuddin KM Nasution Abdullah Hasan Jabbar Sarah Jawad Shoja Waluyo Adi Siswanto Sigiet Haryo Pranoto Dmitry Bokov Rustem Magizov Yasser Fakri Mustafa A. Surendar Rustem Zalilov Alexandr Sviderskiy Alla Vorobeva Dmitry Vorobyev and Ahmed Alkhayyat 《中国物理 B》2022,31(9):96401-096401
Understanding the relation between spatial heterogeneity and structural rejuvenation is one of the hottest topics in the field of metallic glasses (MGs). In this work, molecular dynamics (MD) simulation is implemented to discover the effects of initial spatial heterogeneity on the level of rejuvenation in the Ni$_{80}$P$_{20 }$MGs. For this purpose, the samples are prepared with cooling rates of $10^{10}$ K/s-$10^{12}$ K/s to make glassy alloys with different atomic configurations. Firstly, it is found that the increase in the cooling rate leads the Gaussian-type shear modulus distribution to widen, indicating the aggregations in both elastically soft and hard regions. After the primary evaluations, the elastostatic loading is also used to transform structural rejuvenation into the atomic configurations. The results indicate that the sample with intermediate structural heterogeneity prepared with 10$^{11}$ K/s exhibits the maximum structural rejuvenation which is due to the fact that the atomic configuration in an intermediate structure contains more potential sites for generating the maximum atomic rearrangement and loosely packed regions under an external excitation. The features of atomic rearrangement and structural changes under the rejuvenation process are discussed in detail. 相似文献
4.
A host-guest optical sensor for the determination of aliphatic amines as exemplified by octylamine is proposed. It is based on the reversible fluorescence enhancement of heptakis(2,6-di-O-isobutyl)-β-cyclodextrin(DOB-β-CD) hosting tetraphenylporphyrin (TPP) immobilized in poly(vinyl chloride) (PVC) membrane by aliphatic amine extracted from aqueous phase into membrane phase. The optimum membrane contained 1.15 wt % TPP, 6.15 wt % DOB-β-CD as sensing reagent and other membrane materials. The fluorescence enhancement of the membrane resulted from the formation of a stable three-component complex among DOB-β-CD, TPP, and aliphatic amines. With the optimum conditions described, the fluorescence response of the sensor to octylamine shows a good correlation with the theoretically derived equation in the range 1.0 × 10–6 to 8.0 × 10–4 mol/L. The response characteristics including reversibility, response time, reproducibility and lifetime and selectivity of this optical device are also discussed in detail. This sensor has also been applied for the determination of octylamine in water samples containing interferents with satisfactory recovery. 相似文献
5.
KM Clauwaert Van Bocxlaer JF HJ Major JA Claereboudt WE Lambert Van den Eeckhout EM Van Peteghem CH De Leenheer AP 《Rapid communications in mass spectrometry : RCM》1999,13(14):1540-1545
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
6.
The effects on the radiation response of Harwell polymethylmethacrylate (PMMA) dosimeters of dose-rate, radiation type, temperature during irradiation and post-irradiation storage, and post-irradiation stability, are of importance to the operators of commercial irradiation facilities.
This paper describes recent studies of the effects of some of these parameters on the radiation response of Harwell Red 4034, Amber 3042, and Gammachrome YR Perspex dosimeters, and provides data on batch to batch variation and shelf-life. 相似文献
7.
8.
n.O.e. difference spectra reveal that the preferred solution conformation of methyl enol ethers has the methyl group -periplanar to the double bond; n.O.e kinetics in a methoxy—heptatriene demonstrate the presence of both possible periplanar conformations, the energy difference being 1 kcal/mole. 相似文献
9.
A host-guest optical sensor for the determination of aliphatic amines as exemplified by octylamine is proposed. It is based
on the reversible fluorescence enhancement of heptakis(2,6-di-O-isobutyl)-β-cyclodextrin(DOB-β-CD) hosting tetraphenylporphyrin
(TPP) immobilized in poly(vinyl chloride) (PVC) membrane by aliphatic amine extracted from aqueous phase into membrane phase.
The optimum membrane contained 1.15 wt % TPP, 6.15 wt % DOB-β-CD as sensing reagent and other membrane materials. The fluorescence
enhancement of the membrane resulted from the formation of a stable three-component complex among DOB-β-CD, TPP, and aliphatic
amines. With the optimum conditions described, the fluorescence response of the sensor to octylamine shows a good correlation
with the theoretically derived equation in the range 1.0 × 10–6 to 8.0 × 10–4 mol/L. The response characteristics including reversibility, response time, reproducibility and lifetime and selectivity
of this optical device are also discussed in detail. This sensor has also been applied for the determination of octylamine
in water samples containing interferents with satisfactory recovery.
Received: 21 November 1999 / Revised: 10 January 2000 / Accepted: 15 January 2000 相似文献
1