排序方式: 共有11条查询结果,搜索用时 15 毫秒
1.
R Bonfiglio RC King TV Olah K Merkle 《Rapid communications in mass spectrometry : RCM》1999,13(12):1175-1185
A post-column infusion system was developed in order to analyze suppression of electrospray ionization (ESI) tandem mass spectrometry response in the presence of endogenous plasma interferences. By enabling direct detection of these interfering components, this experimental system was used to analyze the ability of several common extraction procedures to remove endogenous plasma components that cause changes in the ESI response of model drug substances. Methyl-t-butyl ether (MTBE) liquid-liquid, Oasis and Empore solid-phase, and acetonitrile (ACN) protein precipitation sample preparation methods were tested using the post-column infusion system. In all cases, ACN protein precipitation samples showed the greatest amount of ESI response suppression while liquid-liquid extracts demonstrated the least. In addition, the three test compounds, phenacetin, caffeine, and a representative Merck compound, demonstrated that ESI response suppression is compound dependent. Suppression was greatest with caffeine, the most polar analyte, and the smallest for the Merck compound, the least polar analyte. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
2.
Samit Mandal J Gerl H Geissel K Hauschild M Hellström Z Janas I Kojouharov Y Kopatch RC Lemmon P Mayet Z Podolyak PH Regan H Schaffner C Schlegel J Simpson HJ Wollersheim 《Pramana》2001,57(1):161-164
Feasibility of gamma-ray spectroscopy at relativistic energies with exotic heavy-ions and new generation of germanium detectors
(segmented Clover) is discussed. An experiment with such detector array and radioactive is discussed. 相似文献
3.
We report measurements of non-linear charge transport in epitaxial (La1−x
Pr
x
)0.7Ca0.3MnO3 thin films fabricated on (100) oriented SrTiO3 single crystals by pulsed laser deposition. The end members of this series, namely Pr0.7Ca0.3MnO3 and La0.7Ca0.3MnO3 are canonical charge-ordered (CO) and ferromagnetic manganites, respectively. The onset of the CO state in Pr0.7Ca0.3MnO3 is manifested by a pronounced insulating behavior below ∼ 200 K. The CO state remains stable even when a large (∼ 2×105 V/cm) electric field is applied across the thin film samples. However, on substitution of Pr with La, a crossover from the
highly resistive CO state to a state of metallic character is observed at relatively low electric fields. The current-voltage
characteristics of the samples at low temperatures show hysteretic and history dependent effects. The electric field driven
charge transport in the system is modelled on the basis of an inhomogeneous medium consisting of ferromagnetic metallic clusters
dispersed in a CO background. 相似文献
4.
In the present work, five different spectrophotometric techniques for simultaneous determination of formulations containing atorvastatin calcium (ATOR) and fenofibrate (FENO) in various combinations are described. In ratio spectra derivative spectrophotometry, analytical signals were measured at wavelengths corresponding to either maximums or minimums for both drugs in first derivative spectra of ratio spectra obtained by using either spectrum as divisor. For the remaining four methods using chemometric techniques, namely, classical least squares (CLS), inverse least squares (ILS), principal component regression (PCR) and partial least squares (PLS), the calibrations were constructed by using the absorption data matrix corresponding to the concentration data matrix, with measurements in the range of 231 - 310 nm (Deltalambda = 1 nm) in their zero-order spectra. The linearity range was found to be 4 - 22 and 2 - 20 microg/ml for ATOR and FENO, respectively. The validity of the proposed methods was successfully assessed for analyses of both drugs in laboratory-prepared mixtures and in commercial tablet formulations. 相似文献
5.
Four simple, rapid, accurate, precise, reliable and economical spectrophotometric methods have been proposed for simultaneous determination of salbutamol sulphate (SS), bromhexine hydrochloride (BH) and etofylline (ET) in pure and commercial formulations without any prior separation or purification. They were first derivative zero crossing spectrophotometry (method 1), simultaneous equation method (method 2), derivative ratio spectra zero crossing method (method 3) and double divisor ratio spectra derivative method (method 4). The ranges for SS, BH and ET were found to be 1-35 μg mL−1, 4-40 μg mL−1 and 5-80 μg mL−1. For methods 1 and 2, the values of limit of detection (LOD) were 0.2314 μg mL−1, 0.4865 μg mL−1 and 0.2766 μg mL−1 and the values of limit of quantitation (LOQ) were 0.7712 μg mL−1, 1.6217 μg mL−1 and 0.9221 μg mL−1 for SS, BH and ET, respectively. For method 3, LOD values were 0.3297 μg mL−1, 0.2784 μg mL−1 and 0.7906 μg mL−1 and LOQ values were 0.9325 μg mL−1, 0.9282 μg mL−1 and 2.6352 μg mL−1 for SS, BH and ET, respectively. For method 4, LOD values were 0.3161 μg mL−1, 0.2495 μg mL−1 and 0.2064 μg mL−1 and LOQ values were 0.9869 μg mL−1, 0.8317 μg mL−1 and 0.6879 μg mL−1 for SS, BH and ET. The precision values were less then 2% R.S.D. for all four methods. The common excipients and additives did not interfere in their determinations. The results obtained by the proposed methods have been statistically compared by means of Student t-test and by the variance ratio F-test. 相似文献
6.
MA Freitas SR Dillon RC Dougherty AG Marshall 《Rapid communications in mass spectrometry : RCM》1999,13(15):1622-1625
The self-chemical ionization of diethylzinc is examined by Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry and semiempirical molecular orbital calculations. Electron impact of diethylzinc neutral produces the radical cation, C(4)H(15)Zn(+) (m/z x 122), which reacts further with the neutral (C(2)H(5))(2)Zn to give the following product ions: Zn(+) (m/z x 64), C(2)H(5)Zn(+) (m/z x 93), C(4)H(9)Zn(+) (m/z x 121), C(4)H(11)Zn(2)(+) (m/z x 187), and C(6)H(15)Zn(2)(+) (m/z x 215). To determine the structure and pathways for production of these ions, monoisotopic (12)C(4)H(15)(64)Zn(+), (64)Zn(+) and (12)C(2)H(5)(64)Zn(+) were individually isolated and reacted with the neutral background. We also performed semiempirical molecular orbital calculations (ZINDO/1). The molecular orbital calculations and experimental data are consistent in predicting that the ethyl group on the diethylzinc cation carries the positive charge. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
7.
8.
We present evidence for a nonsingular origin of the Universe with intial conditions determined by quantum physics and relativistic
gravity. In particular, we establish that the present temperature of the microwave background and the present density of the
Universe agree well with our predictions from these intial conditions, after evolution to the present age using the Einstein-Friedmann
equation. Remarkably, the quantum origin for the Universe naturally allows its evolution at exactly the critical density.
We also discuss the consequences of these results to some fundamental aspects of quantum physics in the early Universe. 相似文献
9.
10.
Jolly M Sankalia Rajashree C Mashru Mayur G Sankalia Priti P Parikh Vijay B Sutariya 《Analytical sciences》2004,20(9):1321-1325
Two new specific, selective, simple and inexpensive spectroscopic methods for estimating a trace amount of chromium (Cr3+) from a multi-vitamin with multi-mineral pharmaceutical formulations were developed. The proposed methods are based on the conversion of Cr3+ to Cr6+ either by oxidation with a nitric acid-perchloric acid mixture (method I) or by fusion with an excess amount of sodium carbonate (method II), followed by the complexation of Cr6+ with 1,5-diphenylcarbazide (DPC) in a mineral acidic solution of pH 1.0 +/- 0.5. The pink-colored complex was estimated at 544 nm. Both methods were found to be linear in the range of 0.1 - 0.8 microg/ml with a limit of detection in the range of 0.0123 - 0.0157 microg/ml and a limit of quantitation in the range of 0.0419 - 0.0525 microg/ml. Method I was found to be suitable for estimating Cr3+ species in various formulations, like tablets, capsules and syrups, while method II was found to be suitable for tablets and capsules. Satisfactory recovery from spiked samples of standard Cr3+ suggests no interference of any excipients and diverse ions present in the formulations. The developed methods were compared with AAS by ANOVA, and no significant difference was observed. 相似文献