排序方式: 共有53条查询结果,搜索用时 15 毫秒
1.
CV Tomy D Pal SS Banerjee S Ramakrishnan AK Grover S Bhattacharya MJ Higgins G Balakrishnan McK Paul 《Pramana》2002,58(5-6):925-935
The weakly pinned single crystals of the hexagonal 2H-NbSe2 compound have emerged as prototypes for determining and characterizing the phase boundaries of the possible order-disorder
transformations in the vortex matter. We present here a status report based on the ac and dc magnetization measurements of
the peak effect phenomenon in three crystals of 2H-NbSe2, in which the critical current densities vary over two orders of magnitude. We sketch the generic vortex phase diagram of
a weakly pinned superconductor, which also utilizes theoretical proposals. We also establish the connection between the metastability
effects and pinning. 相似文献
2.
3.
Alberti G Brunet E Dionigi C Juanes O de La Mata MJ Rodríguez-Ubis JC Vivani R 《Angewandte Chemie (International ed. in English)》1999,38(22):3351-3353
The hydrophilic oxygen atoms of polyethylenoxide chains inserted as pillars in gamma-zirconium phosphate form hydrogen bonds with the acid groups of the host. As a result the pillars are almost perpendicular to the gamma layers. Upon changing the pH level of the supernatant solution the hydrogen bonds are broken and the pillars become almost perpendicular to the layers (shown schematically). Thus there is a reversible enlargement-shortening of the interlayer space. 相似文献
4.
Culzoni MJ Goicoechea HC Ibañez GA Lozano VA Marsili NR Olivieri AC Pagani AP 《Analytica chimica acta》2008,614(1):46-57
Multivariate curve resolution coupled to alternating least-squares (MCR-ALS) has been employed to model kinetic-spectroscopic second-order data, with focus on the achievement of the important second-order advantage, under conditions of extreme spectral overlapping among sample components. A series of simulated examples shows that MCR-ALS can conveniently handle the studied analytical problem unlike other second-order multivariate calibration algorithms, provided matrix augmentation is implemented in the spectral mode instead of in the usual kinetic mode. The approach has also been applied to three experimental examples, which involve the determination of: (1) the antiparkinsonian carbidopa (analyte) in the presence of levodopa as a potential interferent, both reacting with cerium (IV) to produce the fluorescent species cerium (III) with different kinetics; (2) Fe(II) (analyte) in the presence of the interferent Zn(II), both catalyzing the oxidation of methyl orange with potassium bromate; and (3) tartrazine (analyte) in the presence of the interferent brilliant blue, both oxidized with potassium bromate, with the interferent leading to a product with an absorption spectrum very similar to tartrazine. The results indicate good analytical performance towards the analytes, despite the intense spectral overlapping and the presence of unexpected constituents in the test samples. 相似文献
5.
María del Pilar Godoy-Caballero María Julia Culzoni Teresa Galeano-Díaz María Isabel Acedo-Valenzuela 《Analytica chimica acta》2013
This paper presents the development of a non-aqueous capillary electrophoresis method coupled to UV detection combined with multivariate curve resolution-alternating least-squares (MCR-ALS) to carry out the resolution and quantitation of a mixture of six phenolic acids in virgin olive oil samples. p-Coumaric, caffeic, ferulic, 3,4-dihydroxyphenylacetic, vanillic and 4-hydroxyphenilacetic acids have been the analytes under study. All of them present different absorption spectra and overlapped time profiles with the olive oil matrix interferences and between them. The modeling strategy involves the building of a single MCR-ALS model composed of matrices augmented in the temporal mode, namely spectra remain invariant while time profiles may change from sample to sample. So MCR-ALS was used to cope with the coeluting interferences, on accounting the second order advantage inherent to this algorithm which, in addition, is able to handle data sets deviating from trilinearity, like the data herein analyzed. The method was firstly applied to resolve standard mixtures of the analytes randomly prepared in 1-propanol and, secondly, in real virgin olive oil samples, getting recovery values near to 100% in all cases. The importance and novelty of this methodology relies on the combination of non-aqueous capillary electrophoresis second-order data and MCR-ALS algorithm which allows performing the resolution of these compounds simplifying the previous sample pretreatment stages. 相似文献
6.
7.
8.
M.D. Gil García F. Cañada Cañada M.J. Culzoni L. Vera-Candioti G.G. Siano H.C. Goicoechea M. Martínez Galera 《Journal of chromatography. A》2009,1216(29):5489-5496
An analytical method for the simultaneous determination of seven non-steroidal anti-inflammatory drugs (naproxen, ketoprofen, diclofenac, piroxicam, indomethacin, sulindac and diflunisal) and the anticonvulsant carbamazepine in river and wastewater is reported. The method involves pre-concentration and clean-up by solid-phase microextraction using polydimethylsiloxane/divinylbenzene fibers, followed by liquid chromatography with diode array detection analysis. Owing to the fact that river water samples did not contain interferences and no sensitivity changes due to sample matrix were observed, external calibration was implemented. Standardization was also applied in order to carry out the prediction step by preparing only two diluted standards that were subjected to the pre-concentration step and a set of standards prepared in solvent. For the analysis of wastewater samples, in contrast, it was necessary to implement standard addition calibration in combination with the multivariate curve resolution-alternating least squares (MCR-ALS) algorithm, which allowed us to overcome matrix effect and exploit the second order advantage. Recoveries ranging from 72% to 125% for all pharmaceuticals proved the accuracy of the proposed method in river water samples. On the other hand, wastewater sample recoveries ranged from 83% to 140% for all pharmaceuticals, showing an acceptable performance – considering this sample contains no modeled interferences. 相似文献
9.
María J. Culzoni Agustina V. Schenone Natalia E. Llamas Mariano Garrido Maria S. Di Nezio Beatriz S. Fernández Band Héctor C. Goicoechea 《Journal of chromatography. A》2009,1216(42):7063-7070
A fast chromatographic methodology is presented for the analysis of three synthetic dyes in non-alcoholic beverages: amaranth (E123), sunset yellow FCF (E110) and tartrazine (E102). Seven soft drinks (purchased from a local supermarket) were homogenized, filtered and injected into the chromatographic system. Second order data were obtained by a rapid LC separation and DAD detection. A comparative study of the performance of two second order algorithms (MCR-ALS and U-PLS/RBL) applied to model the data, is presented. Interestingly, the data present time shift between different chromatograms and cannot be conveniently corrected to determine the above-mentioned dyes in beverage samples. This fact originates the lack of trilinearity that cannot be conveniently pre-processed and can hardly be modelled by using U-PLS/RBL algorithm. On the contrary, MCR-ALS has shown to be an excellent tool for modelling this kind of data allowing to reach acceptable figures of merit. Recovery values ranged between 97% and 105% when analyzing artificial and real samples were indicative of the good performance of the method. In contrast with the complete separation, which consumes 10 mL of methanol and 3 mL of 0.08 mol L−1 ammonium acetate, the proposed fast chromatography method requires only 0.46 mL of methanol and 1.54 mL of 0.08 mol L−1 ammonium acetate. Consequently, analysis time could be reduced up to 14.2% of the necessary time to perform the complete separation allowing saving both solvents and time, which are related to a reduction of both the costs per analysis and environmental impact. 相似文献
10.
MJ Singh DO Kataria N Madhavan P Sugathan JJ Das DK Awasthi AK Sinha R Shanker 《Pramana》1999,53(4):743-764
A projectile ion-recoil ion coincidence technique has been employed to study the multiple ionization and the charge transfer
processes in collisions of 60–120 MeV Si
q+ (q = 4−14) ions with neutral argon atoms. The relative contribution of different ionization channels, namely; direct ionization,
electron capture and electron loss leading to the production of slow moving multiply charged argon recoil ions have been investigated.
The data reported on the present collision system result from a direct measurement in the considered impact energy for the
first time. The total ionization cross-sections for the recoil ions are shown to scale as q
1.7/E
p
0.5
, where E
p is the energy in MeV of the projectile and q its charge state. The recoil fractions for the cases of total- and direct ionizations are found to decrease with increasing
recoil charge state j. The total ionization fractions of the recoils are seen to depend on q and to show the presence of a ‘shell-effect’ of the target. Further, the fractions are found to vary as 1/j
2 upto j = 8+. The average recoil charge state 〈j〉 increases slowly with q and with the number of lost or captured electrons from or into the projectile respectively. The projectile charge changing
cross-sections σ
qq′ are found to decrease with increasing q for loss ionization and to increase with q for direct-and capture ionization processes respectively. The physics behind various scaling rules that are found to follow
our data for different ionization processes is reviewed and discussed. 相似文献