A new method for simultaneous quantification of curcuminoids and xanthorrhizol (XNT) in Curcuma xanthorrhiza was developed and validated using high-performance liquid chromatography with diode-array UV–Vis detector. The chromatographic separation was achieved on a Phenomenex C18 at room temperature with the mobile-phase acetonitrile ?0.001% formic acid in gradient elution system and delivered at a flow rate of 1?mL/min. Detection wavelength 425?nm was used for curcuminoids and 224?nm for XNT. System suitability, linearity, precision, accuracy, limit of detection, limit of quantitation, and stability were evaluated and were found in good agreement with Association of Official Analytical Chemists guidelines for single-laboratory validation. The proposed method was found to be precise, accurate, and reliable and also could be applied for the simultaneous quantitative analysis of curcuminoids and XNT in C. xanthorriza raw material and its herbal medicinal product.  相似文献   
2.
Koo C  Godley RF  Park J  McDougall MP  Wright SM  Han A 《Lab on a chip》2011,11(13):2197-2203
We present the development of a microfluidically cryo-cooled planar coil for magnetic resonance (MR) microscopy. Cryogenically cooling radiofrequency (RF) coils for magnetic resonance imaging (MRI) can improve the signal to noise ratio (SNR) of the experiment. Conventional cryostats typically use a vacuum gap to keep samples to be imaged, especially biological samples, at or near room temperature during cryo-cooling. This limits how close a cryo-cooled coil can be placed to the sample. At the same time, a small coil-to-sample distance significantly improves the MR imaging capability due to the limited imaging depth of planar MR microcoils. These two conflicting requirements pose challenges to the use of cryo-cooling in MR microcoils. The use of a microfluidic based cryostat for localized cryo-cooling of MR microcoils is a step towards eliminating these constraints. The system presented here consists of planar receive-only coils with integrated cryo-cooling microfluidic channels underneath, and an imaging surface on top of the planar coils separated by a thin nitrogen gas gap. Polymer microfluidic channel structures fabricated through soft lithography processes were used to flow liquid nitrogen under the coils in order to cryo-cool the planar coils to liquid nitrogen temperature (-196 °C). Two unique features of the cryo-cooling system minimize the distance between the coil and the sample: (1) the small dimension of the polymer microfluidic channel enables localized cooling of the planar coils, while minimizing thermal effects on the nearby imaging surface. (2) The imaging surface is separated from the cryo-cooled planar coil by a thin gap through which nitrogen gas flows to thermally insulate the imaging surface, keeping it above 0 °C and preventing potential damage to biological samples. The localized cooling effect was validated by simulations, bench testing, and MR imaging experiments. Using this cryo-cooled planar coil system inside a 4.7 Tesla MR system resulted in an average image SNR enhancement of 1.47 ± 0.11 times relative to similar room-temperature coils.  相似文献   
3.
Resita Arum Sari  A Suparmi  C Cari 《中国物理 B》2016,25(1):10301-010301
The Dirac equation for Eckart potential and trigonometric Manning Rosen potential with exact spin symmetry is obtained using an asymptotic iteration method. The combination of the two potentials is substituted into the Dirac equation,then the variables are separated into radial and angular parts. The Dirac equation is solved by using an asymptotic iteration method that can reduce the second order differential equation into a differential equation with substitution variables of hypergeometry type. The relativistic energy is calculated using Matlab 2011. This study is limited to the case of spin symmetry. With the asymptotic iteration method, the energy spectra of the relativistic equations and equations of orbital quantum number l can be obtained, where both are interrelated between quantum numbers. The energy spectrum is also numerically solved using the Matlab software, where the increase in the radial quantum number nr causes the energy to decrease. The radial part and the angular part of the wave function are defined as hypergeometry functions and visualized with Matlab 2011. The results show that the disturbance of a combination of the Eckart potential and trigonometric Manning Rosen potential can change the radial part and the angular part of the wave function.  相似文献   
4.
Microbial fuel cells (MFCs) are green energy technologies that exploit microbial metabolism to generate electricity. The widespread implementation of MFC technologies has been stymied by their high cost and limited power. MFC arrays in which device configurations or microbial consortia can be screened have generated significant interest because of their potential for defining aspects that will improve performance featuring high throughput characteristics. However, current miniature MFCs and MFC array systems do not support long-term studies that mimic field conditions, and hence, have limitations in fully characterizing and understanding MFC performances in varieties of conditions. Here, we describe an MFC array device that incorporates microfluidic technology to enable continuous long-term analysis of MFC performance at high throughput utilizing periodic anolyte/catholyte replenishment. The system showed 360% higher power output and 700% longer operating time when compared to MFC arrays without catholyte replenishment. We further demonstrate the utility of the system by reporting its successful use in screening microbial consortia collected from geographically diverse environments for communities that support enhanced MFC performance. Taken together, this work demonstrates that anolyte/catholyte replenishment can significantly improve the long-term performance of microfabricated MFC arrays, and support the characterization of diverse microbial consortia.  相似文献   
5.
J Park  H Koito  J Li  A Han 《Lab on a chip》2012,12(18):3296-3304
Formation of myelin sheaths by oligodendrocytes (OLs) in the central nervous system (CNS) is essential for rapid nerve impulse conduction. Reciprocal signaling between axons and OLs orchestrates myelinogenesis but remains largely elusive. In this study, we present a multi-compartment CNS neuron-glia microfluidic co-culture platform. The platform is capable of conducting parallel localized drug and biomolecule treatments while carrying out multiple co-culture conditions in a single device for studying axon-glia interactions at a higher throughput. The "micro-macro hybrid soft-lithography master fabrication" (MMHSM) technique enables a large number of precisely replicated PDMS devices incorporating both millimeter and micrometer scale structures to be rapidly fabricated without any manual reservoir punching processes. Axons grown from the neuronal somata were physically and fluidically isolated inside the six satellite axon/glia compartments for localized treatments. Astrocytes, when seeded and co-cultured after the establishment of the isolated axons in the satellite axon/glia compartments, were found to physically damage the established axonal layer, as they tend to grow underneath the axons. In contrast, oligodendrocyte progenitor cells (OPCs) could be co-cultured successfully with the isolated axons and differentiated into mature myelin basic protein-expressing OLs with processes aligning to neighboring axons. OPCs inside the six axon/glia compartments were treated with a high concentration of ceramide (150 μM) to confirm the fluidic isolation among the satellite compartments. In addition, isolated axons were treated with varying concentrations of chondroitin sulfate proteoglycan (CSPG, 0-25 μg ml(-1)) within a single device to demonstrate the parallel localized biomolecular treatment capability of the device. These results indicate that the proposed platform can be used as a powerful tool to study CNS axonal biology and axon-glia interactions with the capacity for localized biomolecular treatments.  相似文献   
6.
7.
This paper describes an approach for fabricating multi-layer microfluidic systems from a combination of glass and plastic materials. Methods and characterization results for the microfabrication technologies underlying the process flow are presented. The approach is used to fabricate and characterize multi-layer plastic/glass microfluidic systems containing electrical and mechanical functionality. Hot embossing, heat staking of plastics, injection molding, microstenciling of electrodes, and stereolithography were combined with conventional MEMS fabrication techniques to realize the multi-layer systems. The approach enabled the integration of multiple plastic/glass materials into a single monolithic system, provided a solution for the integration of electrical functionality throughout the system, provided a mechanism for the inclusion of microactuators such as micropumps/valves, and provided an interconnect technology for interfacing fluids and electrical components between the micro system and the macro world.  相似文献   
8.
In recent years, a large number of devices based on organic and biological materials have been developed. To scale-up the production of these systems to industrially acceptable standards, there is a need to develop soft-material stamping approaches with the needed resolution, complexity, and versatility. We have recently developed a DNA-based stamping method (supramolecular nano-stamping, SuNS) that has superior resolution and can print multiple molecules at the same time. A similar technique was independently developed by Crooks and co-workers. Here we show that SuNS can be used to efficiently print DNA features on a polymeric substrate (poly(methyl methacrylate), PMMA) with a 40 nm point resolution and a coverage that exceeds 100 mum2. The stamped PMMA substrate was also used as a master to print on a gold substrate. With PMMA being optically clear and electrically insulating, future applications of SuNS to print DNA micro- and nanoarrays are envisioned.  相似文献   
9.
Kim J  Taylor D  Agrawal N  Wang H  Kim H  Han A  Rege K  Jayaraman A 《Lab on a chip》2012,12(10):1813-1822
We describe the development of a fully automatic and programmable microfluidic cell culture array that integrates on-chip generation of drug concentrations and pair-wise combinations with parallel culture of cells for drug candidate screening applications. The device has 64 individually addressable cell culture chambers in which cells can be cultured and exposed either sequentially or simultaneously to 64 pair-wise concentration combinations of two drugs. For sequential exposure, a simple microfluidic diffusive mixer is used to generate different concentrations of drugs from two inputs. For generation of 64 pair-wise combinations from two drug inputs, a novel time dependent variable concentration scheme is used in conjunction with the simple diffusive mixer to generate the desired combinations without the need for complex multi-layer structures or continuous medium perfusion. The generation of drug combinations and exposure to specific cell culture chambers are controlled using a LabVIEW interface capable of automatically running a multi-day drug screening experiment. Our cell array does not require continuous perfusion for keeping cells exposed to concentration gradients, minimizing the amount of drug used per experiment, and cells cultured in the chamber are not exposed to significant shear stress continuously. The utility of this platform is demonstrated for inducing loss of viability of PC3 prostate cancer cells using combinations of either doxorubicin or mitoxantrone with TRAIL (TNF-alpha Related Apoptosis Inducing Ligand) either in a sequential or simultaneous format. Our results demonstrate that the device can capture the synergy between different sensitizer drugs and TRAIL and demonstrate the potential of the microfluidic cell array for screening and optimizing combinatorial drug treatments for cancer therapy.  相似文献   
10.
Han A  Frazier AB 《Lab on a chip》2006,6(11):1412-1414
A micro electrical impedance spectroscopy system (microEIS) for single cell analysis has been developed and used to differentiate ion channel activities of bovine chromaffin cells. K+ and Ca2+ channels were blocked and their electrical impedances were measured over a frequency range of 100 Hz to 5.0 MHz and compared to that of unblocked chromaffin cells. When ion channels were blocked, an increase in magnitude and decrease in phase of the measured impedances were observed. This result demonstrates that ion channel activities can be distinguished using the developed microsystem and it is expected that this system can be used to provide positive/negative information of ion channel blockage in a high throughput screening setup.  相似文献   