首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   79篇
  免费   5篇
化学   80篇
数学   1篇
物理学   3篇
  2023年   1篇
  2022年   1篇
  2020年   1篇
  2019年   3篇
  2017年   1篇
  2016年   5篇
  2015年   4篇
  2014年   6篇
  2013年   9篇
  2012年   8篇
  2011年   7篇
  2010年   4篇
  2009年   7篇
  2008年   4篇
  2007年   8篇
  2006年   3篇
  2005年   1篇
  2004年   4篇
  2003年   1篇
  2002年   4篇
  2001年   1篇
  1989年   1篇
排序方式: 共有84条查询结果,搜索用时 31 毫秒
1.
In the present work we describe a two‐dimensional liquid chromatographic system (2D‐LC) with detection by mass spectrometry (MS) for the simultaneous separation of endogenous metabolites of clinical interest and excreted xenobiotics deriving from exposure to toxic compounds. The 2D‐LC system involves two orthogonal chromatographic modes, hydrophilic interaction liquid chromatography (HILIC) to separate polar endogenous metabolites and reversed‐phase (RP) chromatography to separate excreted xenobiotics of low and intermediate polarity. Additionally, the present proposal has the novelty of incorporating an on‐line sample treatment based on the use of restricted access materials (RAMs), which permits the direct injection of urine samples into the system. The work is focused on the instrumental coupling, studying all possible options and attempting to circumvent the problems of solvent incompatibility between the RAM device and the two chromatographic columns, HILIC and RP. The instrumental configuration developed, RAM‐HILIC‐RPLC‐MS/MS, allows the simultaneous assessment of urinary metabolites of clinical interest and excreted compounds derived from exposure to toxic agents with minimal sample manipulation. Thus, it may be of interest in areas such as occupational and environmental toxicology in order to explore the possible relationship between the two types of compounds. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   
2.
The fragmentation of heterocyclic amines (HAs) in an ion trap was studied by means of the infusion of methanolic solutions containing the compounds under assay, and using an atmospheric pressure chemical ionization (APCI) as ion source. The MS(n) spectra obtained for compounds included in the same family, either aminoimidazoazaarenes (AIAs) or carbolines, were compared in order to propose fragmentation pathways for each HA. Moreover, labelled AIAs were used to establish the mechanisms. The protonated molecule was always obtained, but subsequent fragmentation was different for both families. In the case of AIAs, major product ions came from the fragmentation of the aminoimidazole moiety, thus the base peak in MS(2) corresponded to the loss of the methyl group, and losses of C(2)NH(3) and CN(2)H(2) were also observed. Further fragmentation occurred in the heterocyclic rings, mainly with losses of HCN and CH(3)CN. For carbolines, the most important product ions came from the loss of ammonia, except for harman and norharman, the loss of a methyl group for methylated carbolines or the loss of diverse fragments from the heterocyclic rings. In some cases, ion-molecule reactions into the ion trap were observed. For instance, for AalphaC or MeAalphaC one ion originating from these reactions corresponded to the base peak.  相似文献   
3.
Heterocyclic amines (HAs), generated when proteinaceous food is cooked, are of special interest since they can be carcinogenic for humans. In this paper, the optimization of a clean-up procedure for the isolation and preconcentration of 15 heterocyclic amines in urine samples is described. The method proposed combines liquid extraction on a solid support of diatomaceous earth with solid-phase extraction in cartridges. Tests were performed on several cartridges containing graphitic carbon or mixed phases, i.e., combining reversed-phase and cation-exchange mechanism, and the best results were obtained with Oasis MCX. The optimized purification method was applied to the quantification of heterocyclic amines in hydrolyzed spiked human urine. The method was carried out by capillary electrophoresis (CE) coupled to mass spectrometry (MS) and applying field-amplified sample injection (FASI) as in-line preconcentration procedure. We obtained detection limits down to 0.3 ng/ml of urine and errors lower than 17%.  相似文献   
4.
5.
6.
7.
Spherical nanoparticles composed of MMX chains can be made by a polymerization strategy driven by electrochemical processes. In particular, the [Pt2(MeCS2)4I2] (MMI2) dimetal subunit is employed as a monomer for the formation of [Pt2(MeCS2)4I]n spherical nanostructures on surfaces. We have paid particular attention to elucidating the general mechanism of the deposition process on the basis of in situ electrochemical measurements. The reduction of MMI2 to give the electrodeposition of nanostructures agrees well with formation of the reduced [MMI2]? species followed by a disproportionation mechanism mediated by iodide anions. The chemical composition of the particles was determined by energy‐dispersive X‐ray spectroscopy (EDX) and X‐ray photoelectron spectroscopy (XPS) to reveal the MMI2 polymer.  相似文献   
8.
The mixed aggregate (MA) method was evaluated for the routine determination of total ethoxylated nonionic surfactants in municipal raw and treated sewage. Nonionics in wastewater samples were enriched with a C8 solid-phase extraction cartridge, eluted with ethyl acetate-methanol, and separated from interferences with stacked strong anionic (quaternary ammonium form) and cationic (benzenesulfonic acid form) exchange columns. Sample extracts were evaporated to dryness and redissolved in distilled water. The total amount of ethoxylates, on a weight basis, was determined by measuring the critical micelle concentration of a mixed micelle made up of ethoxylates and the anionic surfactant sodium dodecyl sulfate, used as the reagent. The dye Coomassie Brilliant Blue G was used as a photometric probe. The minimum amount of ethoxylate required for a single determination was 1 microg. For raw sewage samples, mean recoveries and standard deviations were 98 +/- 6 and 98 +/- 4% at fortification levels of 0.3 and 0.6 microg/mL, respectively. For treated sewage samples, mean recoveries and standard deviations were 95 +/- 2 and 100 +/- 2% at fortification levels of 0.03 and 0.06 microg/mL, respectively. The MA method and the classical bismuth active substances and cobalt thiocyanate active substances procedures were compared. The former offers some significant advantages over the classical procedures in terms of sensitivity, selectivity, precision, simplicity, and rapidity; the type of response is independent of both the molecular weight and the chain length of the surfactant.  相似文献   
9.
Drugs that are used as medicines and also as growth promoters in veterinary care are considered as emerging environmental contaminants and in recent years concern about their potential risk to ecosystems and human health has risen. In this paper we used a method based on liquid chromatography/electrospray tandem mass spectrometry to analyze eight coccidiostatic compounds: diclazuril, dinitrocarbanilide (the main metabolite of nicarbazin), robenidine, lasalocid, monensin, salinomycin, maduramicin and nasarin. Multiple‐stage mass spectrometry (MSn) based on the precursor ions [M+Na]+ (polyether ionophores), [M+H]+ (robenidine) and [M–H]? (diclazuril and dinitrocarbanilide) was used to study the fragmentation of these compounds. MSn data and genealogical relationships were used to propose a tentative assignment of the different fragment ions. Loss of water, decarboxylations, ketone β‐cleavages and rearrangement of cyclic ethers and amide groups were some of the fragmentations observed for these compounds. Liquid chromatography with a sub‐2 µm particle size column was coupled to tandem mass spectrometry (LC/MS/MS) allowing the separation of these compounds in less than 7 min. Method detection limits ranging from 11 to 71 ng L?1 and run‐to‐run values in terms of relative standard deviation (RSD) (up to 12%) were obtained. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   
10.
The influence of ion size and surface charge model in titrations of ionizable polyelectrolytes is studied by means of the Semi Grand Canonical Monte Carlo simulation method in the context of the primitive model. Three models describing a discrete distribution of charged functional groups on the polyelectrolyte and different values for the radius of the background electrolyte spanning from ionic to hydrated radii values were analyzed. The polyelectrolyte titrations were simulated by calculating the degree of ionization versus pH curves at two ionic strengths. The results allow us to quantify the impact of the sizes of the background salt ions and surface functional groups of the polyelectrolyte on the dissociation degree. This influence is explained in terms of the effectiveness of the screening of the charged surface sites. Finally, by comparison with the Non-Linear Poisson–Boltzmann model, the influence of ionic correlations and finite size of the solution ions is assessed.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号