首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   87篇
  免费   2篇
化学   78篇
晶体学   1篇
数学   2篇
物理学   8篇
  2023年   1篇
  2021年   3篇
  2020年   1篇
  2019年   1篇
  2018年   1篇
  2016年   2篇
  2015年   3篇
  2014年   2篇
  2013年   3篇
  2012年   3篇
  2011年   9篇
  2010年   10篇
  2009年   3篇
  2008年   3篇
  2007年   4篇
  2006年   9篇
  2005年   7篇
  2004年   7篇
  2003年   6篇
  2002年   3篇
  2001年   2篇
  2000年   2篇
  1998年   1篇
  1997年   1篇
  1994年   1篇
  1982年   1篇
排序方式: 共有89条查询结果,搜索用时 31 毫秒
1.
 An analytical result is not considered to be complete without a statement of the measurement uncertainty associated with it. Evaluation of measurement uncertainty is therefore an essential part of every determination. In the present study the measurement uncertainty of the result of determination of selenium in the reference material Seronorm Trace Elements Serum was studied. The combination of a digestion procedure using sulfuric acid, V2O5 in H2SO4 and hydrogen peroxide and the continuous flow approach of hydride generation atomic fluorescence spectrometry (HG-AFS) detection was used for selenium determination. The total uncertainty budget was calculated with the help of the GUM Workbench program, in which computations follow the rules of the ’ISO guide to the expression of uncertainty in measurement’. The major sources of uncertainty were found to be due to the recovery of the procedure, measurement of peak heights and the purity of Na2SeO3. A selenium mass fraction of 77.1±4.8 ng/g (with a coverage factor of 2.1, 95% probability) was determined, which is comparable with the recommended value of 80 ng/g. Received: 13 September 2002 Accepted: 23 December 2002 Acknowledgements We would like to thank Tinkara Buˇcar, B.Sc. for useful discussions and the IAEA Vienna, for financial support of the project 11553/RO. Presented at CERMM-3, Central European Reference Materials and Measurements Conference: The function of reference materials in the measurement process, May 30–June 1, 2002, Rogaška Slatina, Slovenia Correspondence to V. Stibilj  相似文献   
2.
Development of a method for very low level selenium determination in water soluble protein and peptide fractions, obtained after various separation procedures, is presented. A hydride generation atomic fluorescence spectrometry (HG-AFS) detection system was optimised and the influence of Cu(II), Sb(V), As(III) and HNO3 interferences in the measurement of Se by HG-AFS was investigated. A destruction procedure using HNO3 and H2O2 was also optimised and the average recovery of the digestion of a solution of selenomethioneine was 92 ± 4% (n=14). Combination of this digestion with the detection system gave reliable results. Accuracy was tested by comparison with two independent methods. A very low detection limit (DL) of 0.2 ng/g of measuring solution was achieved. The whole procedure from weighing to measuring was performed in the same Teflon tube. The addition of HNO3 to the fractions before long term storage at -20°C was necessary to prevent adsorption on the test tubes.Selenium was measured in water soluble protein and peptide fractions obtained after extraction, and Sephadex G-75 chromatography performed on liver samples from: i) hens exposed to As2O3, ii) hens fed with a high fat feed and iii) the certified reference material dogfish liver (CRM DOLT-2). Because of the very low DL we were able to observe the Se distribution in chromatographic fractions of samples of organisms which were not exposed to excess amounts of Se. The presence of selenium associated with metallothioneins was observed.  相似文献   
3.
Mazej Z  Benkic P 《Inorganic chemistry》2003,42(25):8337-8343
The reaction between AgBF4 and excess of SbF5 in anhydrous hydrogen fluoride (aHF) yields the white solid AgSb2F11 after the solvent and the excess of SbF5 have been pumped off. Reaction between equimolar amounts of AgSb2F11 and AgBF4 yields AgSbF6. Meanwhile, oxidation of solvolyzed AgSb2F11 in aHF by elemental fluorine yields a clear blue solution of solvated Ag(II) cations and SbF6- anions. AgSb2F11 is orthorhombic, at 250 K, Pbca, with a=1091.80(7) pm, b=1246.28(8) pm, c=3880.2(3) pm, V=5.2797(6) nm3, and Z=24. The crystal structure of AgSb2F11 is related to the already known crystal structure of H3OSb2F11. Vibrational spectra of AgSb2F11 entirely match the literature-reported vibrational spectra of beta-Ag(SbF6)2, for which a formulation of a mixed-valence AgI/AgIII compound was suggested (AgIAgIII(SbF6)4). On the basis of obtained results it can be concluded that previously reported beta-Ag(SbF6)2 is in fact Ag(I) compound with composition AgSb2F11.  相似文献   
4.
Natural graphite samples with average particle sizes of 5, 10 and 15 μm (NG5 μm, NG10 μm and NG15 μm, respectively) were fluorinated by ClF3 (3 × 104 Pa) at 200 and 300 °C for 2 min. X-ray photoelectron spectra of surface-fluorinated samples showed that surface fluorine concentration increased with increase in the particle size of graphite and reaction temperature. Small amounts of chlorine were also detected in all the fluorinated samples. Raman spectra of original and surface-fluorinated samples indicated that the surface disordering was increased for NG10 μm and NG15 μm. Surface areas were decreased by the fluorination for NG5 μm and NG10 μm but unchanged for NG15 μm. The mesopores with diameter of 1.5-2 nm increased while those of 2-3 nm decreased for all the samples. First coulombic efficiencies for NG10 μm and NG15 μm were highly increased by surface fluorination in 1 mol/dm3 LiClO4-EC/DEC/PC (EC: ethylene carbonate, DEC: diethyl carbonate, PC: propylene carbonate) solution.  相似文献   
5.
Summary. The freezing temperatures of dilute aqueous solutions of some poly(oxyethylene) glycols (PEG, HO–(CH2CH2O) n –H, n varying from 4 to 117) were measured over a solute to solvent mass ratio from 0.0100 to 0.3900. The second and third osmotic virial coefficient (A 22 and A 222) of poly(oxyethylene) glycols in aqueous solution were determined. The molecular weight dependence of the second virial coefficient can be described by a simple relation A 22=2×10–5 M n 1.86, and the third virial coefficient is A 222=0.038A 22 2. The activity coefficients of the solute were calculated using the Gibbs-Duhem equation as applied by Bjerrum. From the osmotic and activity coefficients the excess Gibbs energies of solution, as well as the respective partial molar functions of solute and solvent and the virial pair interaction coefficients for the excess Gibbs energies were estimated. The second and the third osmotic virial coefficients are correlated with the Mc-Millan-Mayer virial coefficients.  相似文献   
6.
The densities of ethanol and ethanol–water mixtures were measured with a vibrating tube densimeter at 25.0, 50.0 and 75.0 °C in the pressure range from 0.10 to 40.00 MPa. Densities were correlated using an empirical model. Partial molar volumes, excess molar volumes, isothermal compressibilities, cubic expansion coefficients and internal pressures were calculated from obtained densities. This study reports the dependence of densities, partial molar volumes, excess molar volumes, isothermal compressibilities, cubic expansion coefficients and internal pressures on composition, temperature and pressure.  相似文献   
7.
In this paper, we demonstrate how to apply recently discovered ferromagnetic nematic liquid crystal for visualisation of magnetic fields. The material exhibits strong optical response to both external electric and magnetic fields, which gives us an opportunity to use it for the detection of an area of magnetic vector field in a way that both, the magnitude and the direction of a given field can be simultaneously measured. We discuss the physical model that describes the behaviour of ferromagnetic liquid crystal placed in a liquid crystal cell and demonstrate the method of extracting the information about an arbitrary magnetic field from the combination of magneto-optic and electro-optic response of the sample placed in that field. We have applied the principle to a special case, where magnetic field was visualised on a 2D area near a cylindrical permanent magnet.  相似文献   
8.
The development and validation of a reliable analytical procedure for the determination of selected metals (Cd, Cr, Cu, Pb, Zn and Mn) in sediments accumulated in the Utrata River (Poland) is described. The aqua regia extraction followed by inductively coupled plasma optical emission spectrometry (ICP-OES) was used for this purpose. The optimized analytical procedure was validated, and adequate quality control actions were implemented in order to provide reliable data. The precision under’ within-laboratory’ reproducibility conditions was estimated from duplicate analysis. Certified reference material (CRM) was used in order to evaluate the accuracy of the results regarding the sewage sludge amended soil CRM 143R. The detection limits for all elements of interest were well-below their content in the investigated sediment samples. The obtained reliable data could be used for assessment of the relationship between human economic activity in the past and the geochemical features of the sediments.  相似文献   
9.
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号