首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The freezing temperatures of dilute aqueous solutions of some poly(oxyethylene) glycols (PEG, HO–(CH2CH2O) n –H, n varying from 4 to 117) were measured over a solute to solvent mass ratio from 0.0100 to 0.3900. The second and third osmotic virial coefficient (A 22 and A 222) of poly(oxyethylene) glycols in aqueous solution were determined. The molecular weight dependence of the second virial coefficient can be described by a simple relation A 22=2×10–5 M n 1.86, and the third virial coefficient is A 222=0.038A 22 2. The activity coefficients of the solute were calculated using the Gibbs-Duhem equation as applied by Bjerrum. From the osmotic and activity coefficients the excess Gibbs energies of solution, as well as the respective partial molar functions of solute and solvent and the virial pair interaction coefficients for the excess Gibbs energies were estimated. The second and the third osmotic virial coefficients are correlated with the Mc-Millan-Mayer virial coefficients.  相似文献   

2.
Summary. The dissociation constants of the two oxime groups of 1,1-bis(pyridinium-4-aldoxime)trimethylene dibromide (TMB-4) were determined using spectrophotometric data. Two numerical methods were applied to treat the overlapping equilibria. The results obtained by both agreed with each other and their mean values at 25°C corrected for the ionic strength of 0.05moldm–3 are pKa1=7.49±0.11 and pKa2=8.96±0.09. These values were discussed in terms of the pKas of 1,1-bis(pyridinium-4-aldoxime)oxydimethylene dichloride (Toxogonin), a similar dioxime, which were derived by extrapolation of literature data.  相似文献   

3.
A sub-micrometer thin-layer DNA modified carbon fiber microcylinder electrode was prepared by electrodeposition of ct-DNA at 1.5V (vs. Ag/AgCl). The voltammetric behavior of dopamine (3-hydroxytyramine) was investigated at the modified electrode. It was found that the modified electrode exhibits a highly electrocatalytic activity toward dopamine oxidation. Differential pulse voltammetry was used for determination of dopamine in pH 7.4 phosphate buffer solution. A linear response of the peak current versus the concentration was found in the range of 4×10–6 to 10–4molL–1 at 10–4molL–1 AA (ascorbic acid) coexistence (R=0.9959) and the range of 6×10–5 to 10–3molL–1 at 10–3molL–1 AA (R=0.9960). The presence of a high concentration of ascorbic acid did not interfere with the determination. The proposed method exhibited good recovery and reproducibility. This method can be applied to the detection of DA in real samples.  相似文献   

4.
A new method of SS-RTP for the determination of trace silver has been established. This method is based on the fact that Ag+, when activated by ,-bipyridyl (bipy) in a media of HAc–NaAc (pH=4.9), can catalyze the reaction of Rhodamine B (RhoB) oxidized by K2S2O8, thus causing the Solid Substrate Room-Temperature Phosphorescence (SS-RTP) of RhoB to be quenched. The activating efficiency of bipy is 6.7 times higher than that of o-phenanthroline (phen). The reduction of the phosphorescence intensity (Ip) of RhoB is directly proportional to the concentration of Ag+ ions in the range of 1.6016.0agspot–1 (0.40µLspot–1). The regression equation of the working curve can be expressed as Ip=18.78+5.100mAg+ (agspot–1) (r=0.9994, n=6), the detection limit is 0.28agspot–1. This rapid, accurate and sensitive method has been successfully applied to the determination of trace silver in tea and human hair samples, and the results agree well with the Atomic Absorption Spectroscopy (AAS) method. The mechanism of the catalyzing reaction is also discussed.  相似文献   

5.
A novel electroanalytical method for the determination of physcion is described for the first time. Physcion yields an adsorption catalytic voltammetric peak at –0.74V (vs. SCE) in 0.4molL–1 NH4Cl–NH3·H2O buffer solution (pH 10.5) at a carbon paste electrode (CPE). The experimental results indicated that physcion is efficiently accumulated at a CPE by adsorption. In the subsequent potential scan, physcion was reduced to a homologous anthrahydroquinone compound. The compound was then immediately oxidized to physcion by the dissolved oxygen in the solution, and then physcion was again reduced at the CPE. As a result, a cyclic catalytic reaction was established. The second-order derivative peak current is proportional to the physcion concentration in the ranges of 2.0×10–104.0×10–9molL–1 (accumulation 90s) and 4.0×10–92.0×10–8molL–1 (accumulation 60s). The limit of detection is 8×10–11molL–1 (S/N=3) for a 120s accumulation time. The method was applied to the direct determination of physcion in the medicinal plant polygonum multiflorum Thumb with satisfactory results.  相似文献   

6.
Summary. Zr5Ir2In4 was synthesized by reaction of the elements in a glassy carbon crucible in a water-cooled sample chamber of an induction furnace. The sample was characterized by X-ray diffraction on both powder and single crystals. Zr5Ir2In4 crystallizes with a pronounced Lu5Ni2In4 type subcell, space group Pbam, a=1739.5(6), b=766.3(2), c=338.9(2) pm. Weak additional reflections force a doubling of the subcell c axis. The superstructure of Zr5Ir2In4 is of a new type: Pnma, a=1739.5(6), b=677.8(2), c=766.3(2) pm, wR2=0.0529, 1592 F2 values, and 60 variable parameters. The group-subgroup scheme for the klassengleiche symmetry reduction is presented. The formation of the superstructure is most likely due to a puckering effect (size of the iridium atoms). The crystal chemistry of Zr5Ir2In4 is briefly discussed.  相似文献   

7.
Summary. The equiatomic rare earth metal–iridium–silicides REIrSi (RE=Ce, Pr, Er, Tm, Lu) were prepared by arc-melting of the elements and subsequent annealing. All silicides were characterized through their X-ray powder patterns. The structures of CeIrSi, ErIrSi, and LuIrSi were refined from X-ray single crystal diffractometer data: LaIrSi type, P213, a=629.15(2)pm, wR2=0.1232, 280F2 values, and 11 variable parameters for CeIrSi; TiNiSi type, Pnma, a=673.4(1), b=416.07(5), c=744.88(9)pm, wR2=0.0705, 339F2 values, and 20 variable parameters for ErIrSi, and a=664.0(3), b=412.9(1), c=742.6(1)pm, wR2=0.0398, 496F2 values, and 20 variable parameters for LuIrSi. The iridium and silicon atoms in CeIrSi, ErIrSi, and LuIrSi build three-dimensional [IrSi] networks where the iridium atoms have three (CeIrSi, Ir–Si 229pm) and four (ErIrSi, Ir–Si 247–258pm; LuIrSi, Ir–Si 245–256pm) silicon neighbors. The [IrSi] networks leave larger channels in which the cerium, erbium, and lutetium atoms are located. Temperature dependent susceptibility data for LuIrSi indicate Pauli paramagnetism. CeIrSi shows Curie-Weiss paramagnetism above 100K with an experimental magnetic moment of 2.56(2)B/Ce atom. With samarium as rare earth metal component the silicide SmIr0.266(8)Si1.734(8) with -ThSi2 type structure was obtained: I41/amd, a=409.3(1), c=1397.2(5)pm, wR2=0.0575, 161F2 values, and 9 variable parameters. Within the three-dimensional [Ir0.266Si1.734] network the Ir/Si–Ir/Si distances range from 230 to 237pm.  相似文献   

8.
A new method for the simultaneous determination of heavy metal ions in Chinese herbal medicine by microwave digestion and reversed-phase high-performance liquid chromatography (RP-HPLC) has been developed. The Chinese herbal medicine samples were digested by microwave digestion. Lead, cadmium, mercury, nickel, copper, zinc, and tin ions in the digested samples were pre-column derivatized with tetra-(4-chlorophenyl)-porphyrin (T4-CPP) to form the colored chelates which were then enriched by solid phase extraction with C18 cartridge and eluted from the cartridge with tetrahydrofuran (THF). The chelates were separated on a Waters Xterra RP18 column by gradient elution with methanol (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) and THF (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) as mobile phase at a flow rate of 0.5mLmin–1 and detected with a photodiode array detector in the range of 350–600nm. In the original samples the detection limits of lead, cadmium, mercury, nickel, copper, zinc and tin are 4ngL–1, 3ngL–1, 6ngL–1, 5ngL–1, 2ngL–1, 6ngL–1, and 4ngL–1, respectively. This method was applied to the determination of lead, cadmium, mercury, nickel, copper, zinc and tin in Chinese herbal medicine samples with good results.  相似文献   

9.
Summary. The reactivity of a well defined Rh (I) complex, i.e. Rh(CF3COO)(NHC)(COD) (1, NHC=1,3-bis(2,4,6-trimethylphenyl)-3,4,5,6-tetrahydropyrimidin-2-ylidene, COD=4-cycloocta-1,5-diene) in the hydrosilylation of 1-alkenes, alkynes, and ,-unsaturated carbonyl compounds, respectively, is described. With this complex, excellent reactivity was observed and turn-over numbers (TONs) up to 1000 were reached. A supported version of 1 was realized by reaction of RhCl(NHC)(COD) with PS-DVB–CH2–O–CO–CF2–CF2–CF2–COOAg (PS-DVB=poly(styrene-co-divinylbenzene) to yield PS-DVB–CH2–O–CO–CF2–CF2–CF2–COORh(NHC)(COD). This supported version of 1 exhibited at least comparable, in some cases increased reactivity compared to 1 and allowed the rapid removal of the catalyst from the reaction mixture. Due to reduced catalyst bleeding, the synthesis of target compounds with a Rh-content of less than 130ppm was accomplished.This revised version was published online in February 2005. In the previous version the issue was not marked as a special issue, and the issue title and the editor was missing  相似文献   

10.
Two procedures for wet decomposition of human hair samples were compared for selenium determination by hydride generation atomic absorption spectrometry (HGAAS). These procedures involve treatment with HNO3/H2O2 and H2SO4/HNO3, respectively, using small disposable polypropylene (PP) vials. Analytical steps from weighing to dilution were performed in the same individual PP vial. After sample weighing (10±3mg) and reagent addition, decomposition was performed in a conventional oven (20h, 100°C). Addition of sulfamic acid prior to HGAAS measurements was necessary to minimize interference due to residual nitrogen oxides from the decomposition step. The accuracy was estimated using certified hair reference analysis which yielded an agreement higher than 97% (recovery tests). The absolute limit of detection was 1.2ng (3 s; n=10), corresponding to 0.12µgg–1 in the dry sample.  相似文献   

11.
A microbial sensor for rapid determination of the concentration of biodegradable pollutants in wastewater has been developed using the salt-tolerant yeast Arxula adeninivorans LS3 immobilized by gel entrapment with poly (carbamoyl) sulfonate hydrogel (PCS gel) on a Clark-type oxygen electrode. This sensor needs 5min for every measurement instead of 5 days for BOD5. The sensor has a linear response of up to 550mgL–1 BOD with a correlation of coefficient R2=0.9785. The detection limit was calculated to be 2.1mgL–1 BOD equivalents, and the determination limit was 6.0mgL–1 BOD equivalents. The high tolerance to salt of the Arxula adeninivorans LS3 strain prevents the inactivation of cells caused by the seawater from affecting the measurements. In a 24-hour comparative study using real wastewater samples from an international college situated in Hong Kong, the microbial sensor showed a very good correlation (R2=0.9134) with the standard BOD5 method and truly reflected the life cycle of the college people. The microbial sensor allows almost ideal real-time monitoring in water pollution and degradation.  相似文献   

12.
A new method has been developed for in-situ separation of Pd from a Pt matrix and determination of trace Pd based on different vaporization temperatures by electrothermal vaporization (ETV) inductively coupled plasma optical emission spectrometry (ICP-OES) with the use of polythioether backbone modified with a diaminoisopropylmercaptane chelating group (YPA4), both as solid phase extractant and chemical modifier. In 0.5M HNO3, Pd and Pt can be adsorbed by YPA4. The resin loaded with Pd and Pt was then prepared to form a slurry that can be directly introduced into the graphite furnace without any pretreatment. The factors affecting in-situ separation of Pd from the Pt matrix were investigated in detail. It was found that, in the presence of YPA4, Pd could be quantitatively vaporized at lower vaporization temperatures (1800°C–1900°C), while Pt could not be vaporized from the graphite furnace at the same temperature, its quantitative vaporization temperature being 2600°C. Based on the different vaporization temperatures, in-situ separation of Pd from the Pt matrix and determination of trace Pd by ETV-ICP-OES was achieved in the temperature range of 1800°C–1900°C. Under the optimized conditions, the detection limit (3) of Pd is 60pg, and the relative standard deviation (RSD) is 5.6% (n=9, C=0.2µgmL–1). The method has been applied to the determination of trace Pd in anode slime and Auto Catalyst NIST SRM 2557 reference material, and the determined values coincide with the certified values.  相似文献   

13.
Summary. (A) The origin of exciton interaction and examples of its application to organic stereochemistry are presented. (B) N,N-Carbonyl-bridged dipyrrinones constitute a new class of highly fluorescent chromophores suitable for investigations of stereochemistry and absolute configuration. N,N-Carbonylxanthobilirubic acid esters are strongly fluorescent, with a fluorescence quantum yield (F) 0.8, but produce only weak exciton CD from the trans-1,2-cyclohexanediol template. The ester of an analog with benzoic acid replacing propionic, N,N-carbonyl-8-(4-carboxyphenyl)-3-ethyl-2,7,9-trimethyl-(10H)-dipyrrin-1-one, exhibits strong fluorescence (F=0.68, em=493nm, ex=422nm in CHCl3) and UV-Vis absorption (21000 at 424nm) in organic solvents. Its diester with (1S,2S)-cyclohexanediol is fluorescent and exhibits exciton circular dichroism (=+15dm3·mol–1·cm–1, =432nm; =–4dm3·mol–1cm–1, =380nm) that correlates with the Exciton Chirality Rule.  相似文献   

14.
The polarographic reduction and catalytic behavior of lovastatin are studied by polarography and cyclic voltammetry. The reduction wave of lovastatin appears at ca. –1.49V (vs. SCE) in 0.16molL–1 Na2B4O7–KH2PO4 (pH=7.4) supporting electrolyte containing 20% ethanol. It is ascribed to a 2e, 2H+ addition to the carbonyl group on lactone ring. If H2O2 is present, the reduction wave is catalyzed to produce a polarographic catalytic wave. Based on the catalytic wave, a novel method for the determination of lovastatin is proposed. A rectilinear calibration curve of the catalytic wave was obtained for lovastatin concentration in the range 1.5×10–8 to 1.0×10–6molL–1. The peak current of the catalytic wave is ca. 12 times higher than that of the corresponding reduction wave. The detection limit is 8.0×10–9molL–1. The proposed method is simpler, faster and more sensitive than the known methods for lovastatin analysis, and can be applied to the direct determination of lovastatin in pharmaceuticals, urine and serum without preliminary separation.  相似文献   

15.
Summary. Steady state quenching studies of curcumin, 1,7-bis(4-hydroxy-3-methoxyphenyl)-1,6-heptadiene-3,5-dione, fluorescence by hydrogen peroxide were conducted in acetonitrile solution. A quenching rate constant, kq, of 1.05×1010M–1·s–1 was obtained with a short fluorescence lifetime of 347ps. The reaction rate constant, which is within the diffusion-limited regime, is activation-controlled. The rate constant of deactivation of the thermally excited curcumin was 1.2 orders of magnitude more nonradiative (2.67×109s–1) than radiative (2.16×108s–1). The reaction was exothermic with a G° of –1.97eV and solvent reorganization energy of 1.37eV. These values indicate that the electron transfer reaction is solvent-mediated with electron transfer rate constant, kET, of 2.16×1010s–1.  相似文献   

16.
Thallium in natural water samples was determined by electrothermal atomic absorption spectrometry after 1000-fold enrichment by mini solid-phase extraction from a 100-mL sample solution. A Tl-pyrrolidine-1-carbodithioate complex formed in a sample solution of pH 1.6 was extracted on fine particles of a cellulose nitrate resin dispersed in the sample solution. The cellulose nitrate resin was then collected on a membrane filter (25mmø) by filtration under suction using a glass funnel with an effective filtration area of 0.64cm2. As a result, a circular thin layer of the resin phase with a diameter of 9mm was obtained. Then the resin phase was carved out by an acrylate resin puncher with a 10-mmø hole to put it into a sample cup containing 100µL of 10mM HNO3 containing 0.5mM NaCl. The resin phase was suspended in the solution by ultrasonication. 1000-fold enrichment was thus attained within 15min, and the suspension was delivered to electrothermal atomic absorption spectrometry. The linear calibration graph was obtained in the range of 0–4ng of Tl in 100mL of a sample solution. The detection limit obtained by 3 method was 0.19ng. The proposed method was applied to the determination of Tl in natural water samples. The results showed the concentration of Tl in seawater was 12.1±1.8pgmL–1 for the calibration graph method and 12.6±1.4pgmL–1 for the standard addition method. A snowmelt sample contained 20.7±1.0pgmL–1 of Tl.  相似文献   

17.
A flow-injection procedure for the determination of iron(III) in water is described. The procedure is based on the formation of an ion pair between the tetraphenylarsonium (Ph4As+) (TPA) or tetrabutylammonium (But4N+) (TBA) cations and the tetrathiocyanatoferrate(III) complex (TTF). This ion pair is extracted with chloroform, and the absorbance of the organic phase is measured at 503nm (for Ph4As+) or 475nm (for But4N+). Iron concentrations higher than 0.9×10–6molL–1 (50µgL–1) can be detected in the first case, with a relative standard deviation of 1.9% (n=12), a linear application rangeof between 1.34 and 54.0×10–6molL–1 (75–3015µgL–1), and a sampling frequency of 30h–1. For the ion pair with But4N+, the detection limit is 0.52×10–6molL–1 (29µgL–1), with a relative standard deviation of 1.6% and a linear application range between 0.73 and 54.0×10–6molL–1. Under the proposed working conditions, only Pd(IV), Cu(II) and Bi(III) interfere. With the application of the merging zones technique, considerable amounts of organic reagent can be saved. The TBA method was applied to the analysis of iron(III) in tap and industrial waste waters.  相似文献   

18.
A novel method for the determination of proteins in aqueous solutions has been developed based on the enhancement of resonance light scattering (RLS) of Ag nanoparticles in the presence of proteins. Factors including acidity of the media, concentration of Ag hydrosol, reaction time, temperature, and interference of non-protein substances were investigated. Under the optimal conditions, with the enhanced RLS signals at 452nm, the linear ranges of calibration curves were 0–0.8µgmL–1 for bovine serum albumin (BSA), 0–1.2µgmL–1 for human serum albumin (HSA), and 0–2.5µgmL–1 for human -IgG (-IgG), respectively. The detection limits were 1.3ngmL–1 for BSA, 10ngmL–1 for HAS, and 5.7ngmL–1 for -IgG.This method has been applied to the analysis of synthetic samples and real human serum samples, and the results were in good agreement with those reported by the hospital, indicating that the method presented here is not only sensitive and simple, but also reliable and suitable for practical applications.  相似文献   

19.
A microcolumn on-line preconcentration and separation system was developed for the flame atomic absorption spectrometric (FAAS) determination of trace levels of gold and palladium. The analytes were selectively adsorbed onto the microcolumn packed with 2-mercaptothiazole immobilized silica gel (MBTSG) in an acidity range of 0.1 to 6.0M HCl at a sampling flow rate of 4.0mLmin–1. The analytes adsorbed could be desorbed by a thiourea solution with a flow rate of 2.0mLmin–1. Most of the common coexisting metal ions at a concentration of 25.0mgmL–1 and anions at a concentration of 50.0mgmL–1 did not interfere with the preconcentration and determination of Au and Pd. The limits of detection (LOD), defined as three times the standard deviation of the blank (3), of Au and Pd are 10ngmL–1 and 26ngmL–1, respectively, with a preconcentration time of 60s. The relative standard deviation (RSD) is about 2.0% for 0.20µgmL–1 Au and 0.30µgmL–1 Pd. With a sample loading time of 30min, 6.7ngmL–1 Au and 10ngmL–1 Pd can be preconcentrated quantitatively. A geological sample, an anode slime and a secondary nickel alloy were successfully determined with the proposed method, and the results obtained showed good agreement with the certified values.Received December 23, 2002; accepted May 14, 2003 Published online August 8, 2003  相似文献   

20.
NMR imaging and spatially resolved diffusometry have been used to study the distribution of water within swollen cellophane and measure its diffusion coefficient. Water concentration and diffusion coefficient were found to be essentially constant across most of the film thickness. However, significantly slower diffusion was indicated for water near the film surface (D=0.5×10–9m2s–1) compared with water in the centre of the film (D=0.88×10–9m2s–1). This was also reflected in lower T 2 values at the edge of the film indicating water with more restricted motion. These observations were interpreted in terms of dense surface regions of cellulose (skin) over a more porous interior (core).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号