首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   22篇
  免费   0篇
  国内免费   1篇
化学   12篇
数学   1篇
物理学   10篇
  2012年   1篇
  2006年   1篇
  2003年   3篇
  2002年   4篇
  2001年   1篇
  2000年   4篇
  1999年   3篇
  1994年   1篇
  1993年   2篇
  1992年   1篇
  1988年   1篇
  1987年   1篇
排序方式: 共有23条查询结果,搜索用时 31 毫秒
1.
2.
Null AP  Hannis JC  Muddiman DC 《The Analyst》2000,125(4):619-626
Electrospray ionization mass spectrometry (ESI-MS) has been utilized to obtain accurate mass measurements of intact PCR products; however, single-stranded PCR products are necessary to detect sequence modifications such as base substitutions, additions or deletions. The locations of these modifications can subsequently be determined using additional stages of mass spectrometry. The recombinant enzyme lambda exonuclease selectively digests one strand of a DNA duplex from a 5' phosphorylated end leaving the complementary strand intact. Using this rapid enzymatic step, we were able to produce single-stranded PCR products by digestion of an intact PCR product derived from the Human Tyrosine Hydroxylase (HUMTHO1) gene, which contains a tetrameric repeating motif. The non-template directed 3' adenylation common when using Taq polymerase resulted in three distinct species (blunt-ended, mono-adenylated and di-adenylated), which added complexity to the spectrum of the double-stranded product. The data from the single-stranded products shows that one strand is preferentially adenylated over the other, which cannot be determined from the mass spectrum of the double-stranded PCR product alone. The ESI-FTICR (Fourier transform ion cyclotron resonance) mass spectra of the lambda exonuclease treated PCR products exhibited less than expected signal-to-noise (S/N) ratios. This is attributed to inaccurate concentration calculations due to remaining double-stranded PCR product amplified with unphosphorylated primers, and to matrix effects contributed by the lambda exonuclease reaction buffer. To further test this hypothesis, we investigated and determined the limit of detection to be 0.27 microM using standard curve statistics for single acquisitions of a synthetic 75-mer. The concentrations of the noncoding and coding strands produced by lambda exonuclease digestion were calculated to be 0.29 and 0.37 microM, respectively, taking into account the presence of double-stranded product. The products were electrosprayed from concentrations at the limit of detection requiring the averaging of 5-10 acquisitions to produce a sufficient S/N ratio, indicating that product concentration, base composition and matrix effects play a combined, significant role in detection of lambda exonuclease treated PCR products. Although additional work will be required to further exploit this strategy, lambda exonuclease clearly provides mass spectrometrists with a method to generate single-stranded PCR products.  相似文献   
3.
4.
Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS) has been used to determine the mass of a double-stranded 500 base-pair (bp) polymerase chain reaction (PCR) product with an average theoretical mass of the blunt-ended (i.e. unadenylated) species of 308 859.35 Da. The PCR product was generated from the linearized bacteriophage Lambda genome which is a double-stranded template. Utilization of ethanol precipitation in tandem with a rapid microdialysis step to purify and desalt the PCR product was crucial to obtain a precise mass measurement. The PCR product (0.8 pmol/μL) was electrosprayed from a solution containing 75% acetonitrile, 25 mM piperidine, and 25 mM imidazole and was infused at a rate of 200 nL/min. The average molecular mass and the corresponding precision were determined using the charge-states ranging from 172 to 235 net negative charges. The experimental mass and corresponding precision (reported as the 95% confidence interval of the mean) was 309 406 +/- 27 Da (87 ppm). The mass accuracy was compromised due to the fact that the PCR generates multiple products when using Taq polymerase due to the non-template directed 3'-adenylation. This results in a mixture of three PCR products with nearly identical mass (i.e. blunt-ended, mono-adenylated and di-adenylated) with unknown relative abundances that were not resolved in the spectrum. Thus, the experimental mass will be a weighted average of the three species which, under our experimental conditions, reflects a nearly equal concentration of the mono- and di-adenylated species. This report demonstrates that precise mass measurements of PCR products up to 309 kDa (500 bp) can be routinely obtained by ESI-FTICR requiring low femtomole amounts. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
5.
The chemical composition of a poly(benzoxazine) thermoset polymer (a copolymer of bisphenol-A benzoxazine and tert.-butylphenol benzoxazine) has been studied by pyrolysis-gas chromatography (Py-GC). Major pyrolysates have been identified and the possible degradation pathways have been investigated. A specific pyrolysate was identified for quantitative analysis after carefully proving the linear relationship between the pyrolysate signal intensity and monomer concentration over a wide range of compositions. A method to determine the concentration of the monomer that potentially acts as a cross-linking unit has been developed. In this study, Py-GC was shown to be an excellent analytical technique for the qualitative and quantitative analysis of thermoset polymers.  相似文献   
6.
Elimination of PCR buffer components and alkali metal cations (i.e., Na+, K+) is of critical importance to allow for accurate mass measurements of PCR products for genotyping and sequencing applications. Ethanol precipitation followed by microdialysis has been repeatedly shown to efficiently desalt PCR products for analysis by mass spectrometry and is considered the gold standard. Alternative cleanup techniques that are compatible with automation are explored here with the intent of expanding the bottleneck that exists between the production of PCR products and analysis by electrospray ionization mass spectrometry (ESI-MS). Numerous combinations of approaches were evaluated that included PCR purification kits and alcohol precipitations. The data shown here support alternative approaches to an ethanol precipitation followed by microdialysis that have comparable desalting efficiency and can be utilized for cleanup of PCR products generated from single reactions.  相似文献   
7.
基于双嘧啶和双巴比妥酸的氢键组装体的理论研究   总被引:1,自引:0,他引:1  
用AM1方法对双嘧啶和双巴比妥酸以及二者以1:1的摩尔比通过分子间多重氢键自组织形成的二体进行了几何构型优化,得到氢键键能。并在此基础上用INDO-CI方法讨论了三者的UV-Vis光谱,结果与实验值符合得很好,证实了多重氢键导致新的超分子聚集体的生成,并讨论了氢键在超分子聚集体形成过程中的作用本质。  相似文献   
8.
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
9.
This is the report of Heavy Ion Physics and Quark-Gluon Plasma at WHEPP-09 which was part of Working Group-4. Discussion and work on some aspects of quark-gluon plasma believed to have created in heavy-ion collisions and in early Universe are reported.  相似文献   
10.
AP Balachandran 《Pramana》2002,59(2):359-368
We review certain emergent notions on the nature of space-time from noncommutative geometry and their radical implications. These ideas of space-time are suggested from developments in fuzzy physics, string theory, and deformation quantization. The review focuses on the ideas coming from fuzzy physics. We find models of quantum space-time like fuzzy S 4 on which states cannot be localized, but which fluctuate into other manifolds like CP3. New uncertainty principles concerning such lack of localizability on quantum space-times are formulated. Such investigations show the possibility of formulating and answering questions like the probability of finding a point of a quantum manifold in a state localized on another one. Additional striking possibilities indicated by these developments is the (generic) failure of CPT theorem and the conventional spin-statistics connection. They even suggest that Planck’s ‘constant’ may not be a constant, but an operator which does not commute with all observables. All these novel possibilities arise within the rules of conventional quantum physics, and with no serious input from gravity physics.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号